PubMed Health⌕ Search

Biomedical subjects

Fernando Mora

Publications and source records attributed to Fernando Mora.

3 recordsLinked to original sources

Stochastic resonance in a linear system: An exact solution.

Multistable systems can exhibit stochastic resonance which is characterized by the amplification of small periodic signals by additive noise. Here we consider a nonmultistable linear system with a multiplicative noise forced by an external periodic signal. The noise is the sum of a colored noise of mean value zero and a noise with a definite sign. We show that the system exhibits stochastic resonance through the numerical study of an exact analytical expression for the mean value obtained by functional integral techniques. This is proof of the effect for a very general kind of noise which can even have a definite sign.

Journal Article↗

[Design of an impedance plethysmograph for reactive hyperemia evaluation in the forearm].

Impedance pletismography is based on the evaluation of the voltage change that occur as a consequence of blood flow variations in a particular tissue section. Current applied for the procedure should be alternating, weak and of high frequency to avoid electrically excitable cells stimulation, such as muscles and nerves. Blood volume changes can be measured by this method and has been applied in the diagnosis of deep venous thrombosis of limbs. An impedance meter was designed and built to be used in the forearm of patients. It consists of a voltage stabilizer TPS 76150 with simultaneous ECG recording (DII lead). Injected signal had 50 KHz (Wien's bridge) and registered through two operational amplifiers LM 3080 (1 mA). Signal was demodulated and amplified. Electrodes used were made of silver strips with conductance improved by conductivity gel, fixed by elastic rubber strips. Circuit wiring and equisition software was developed at the Bioengineering Department of Simón Bolívar University. Fifteen healthy subjects, age range 18-30 years old, were submitted to noninvasive forearm blood flow evaluation with the already described electronic device. Brachial artery occlusions were made with a cuff at subdiastolic, supradiastolic and suprasystolic blood pressures, for 60 and 90 seconds and then this occlusion was abruptly released. The curve was displayed and recorded in a portable PC (laptop). During suprasystolic occlusion the impedance observed curve showed a progressive increased until stabilization. When occlusion was released a sudden peak appeared which corresponds to reactive hyperemia of the forearm. This peak has been associated to the secretion of endothelial vasodilatory substances. In conclusion, this device is suitable to be used in clinical settings for the evaluation of reactive hyperemia and potentially useful in diagnosis of deep veins occlusions.

Adult↗

Model-based interpretation of cardiac beats by evolutionary algorithms: signal and model interaction.

This paper presents a new approach for cardiac beat interpretation, based on a direct integration between a model and observed ECG signals. Physiological knowledge is represented by means of a semi-quantitative model of the cardiac electrical activity. The interpretation of cardiac beats is formalized as an optimization problem, by minimizing an error function defined between the model's output and the observations. Evolutionary algorithms (EAs) are used as the search technique in order to obtain the set of model parameters reproducing at best the observed phenomena. Examples of model adaptation to three different kinds of cardiac beats are presented. Preliminary results show the potentiality of this approach to reproduce and explain complex pathological disorders and to better localize their origin.

Algorithms↗