The effects of the addition of manganese to a series of TiO(2)-supported cobalt Fischer-Tropsch (FT) catalysts prepared by different methods were studied by a combination of X-ray diffraction (XRD), temperature-programmed reduction (TPR), transmission electron microscopy (TEM), and in situ X-ray absorption fine structure (XAFS) spectroscopy at the Co and Mn K-edges. After calcination, the catalysts were generally composed of large Co(3)O(4) clusters in the range 15-35 nm and a MnO(2)-type phase, which existed either dispersed on the TiO(2) surface or covering the Co(3)O(4) particles. Manganese was also found to coexist with the Co(3)O(4) in the form of Co(3-x)Mn(x)O(4) solutions, as revealed by XRD and XAFS. Characterization of the catalysts after H(2) reduction at 350 degrees C by XAFS and TEM showed mostly the formation of very small Co(0) particles (around 2-6 nm), indicating that the cobalt phase tends to redisperse during the reduction process from Co(3)O(4) to Co(0). The presence of manganese was found to hamper the cobalt reducibility, with this effect being more severe when Co(3-x)Mn(x)O(4) solutions were initially present in the catalyst precursors. Moreover, the presence of manganese generally led to the formation of larger cobalt agglomerates ( approximately 8-15 nm) upon reduction, probably as a consequence of the decrease in cobalt reducibility. The XAFS results revealed that all reduced catalysts contained manganese entirely in a Mn(2+) state, and two well-distinguished compounds could be identified: (1) a highly dispersed Ti(2)MnO(4)-type phase located at the TiO(2) surface and (2) a less dispersed MnO phase being in the proximity of the cobalt particles. Furthermore, the MnO was also found to exist partially mixed with a CoO phase in the form of rock-salt Mn(1-x)Co(x)O-type solid solutions. The existence of the later solutions was further confirmed by scanning transmission electron microscopy with electron energy loss spectroscopy (STEM-EELS) for a Mn-rich sample. Finally, the cobalt active site composition in the catalysts after reduction at 300 and 350 degrees C was linked to the catalytic performances obtained under reaction conditions of 220 degrees C, 1 bar, and H(2)/CO = 2. The catalysts with larger Co(0) particles ( approximately >5 nm) and lower Co reduction extents displayed a higher intrinsic hydrogenation activity and a longer catalyst lifetime. Interestingly, the MnO and Mn(1-x)Co(x)O species effectively promoted these larger Co(0) particles by increasing the C(5+) selectivity and decreasing the CH(4) production, while they did not significantly influence the selectivity of the catalysts containing very small Co(0) particles.

Journal Article↗

How to assess post-occlusive reactive hyperaemia by means of laser Doppler perfusion monitoring: application of a standardised protocol to patients with peripheral arterial obstructive disease.

The standardisation of manoeuvres to perform clinically discriminative microvascular flow reserve tests is still poorly developed, as well as the response analysis. The aim of this study was to establish a reproducible analysis method for the post-occlusive reactive hyperaemia (PORH) test measured using laser Doppler perfusion monitoring (LDPM). LDPM data were measured from the PORH response of 24 Fontaine class II-III peripheral atherosclerotic/arterial obstructive disease (PAOD) patients and 30 healthy subjects. The PORH response was recorded from the dorsum of the foot after 3 min of arterial occlusion at the thigh. The resulting tracings were analysed by describing their morphology through five defined parameters: resting flux (RF), time to RF level (tRF), maximum flux (MF) during reactive hyperaemia, time to maximum flux (tMF), and time to half recovery (tHR). While the time parameters were discriminative between patients and controls, flux parameters were not. The time to resting flux (tRF) led to the most discriminative model that correctly predicted 88.5% of the cases. Hence, we concluded that obtaining t(RF) with the presented procedures provides an optimal model to quantify the patient's microvascular condition from the PORH response.

Adult↗

A model for post-occlusive reactive hyperemia as measured with laser-Doppler perfusion monitoring.

To facilitate the quantitative analysis of post-occlusive reactive hyperaemia (PORH), measured with laser-Doppler perfusion monitoring (LDPM) on extremities, we present a flow model for the dynamics of the perfusion of the tissue during PORH, based on three parameters: two time constants (tau1 and tau2) and the ratio of the maximum flux and the resting flux. With these three constants quantitative comparisons between experiments will be possible and, therefore, we propose to adopt this approach as future standard. For this reason, we also developed a computer program to perform the fit of the model to measured data.

Algorithms↗

The influence of probe fiber distance on laser Doppler perfusion monitoring measurements.

Laser Doppler perfusion monitoring (LDPM) is a noninvasive technique for monitoring skin microcirculation. The aim of this article was to investigate the influence of fiber separation on clinical LDPM measurements. A dual-channel LDPM system was used in combination with a probe that consists of two sets of detection fibers, at 0.2 and 1.0 mm from the illuminating fiber. Measurements were performed at the big toe of 8 healthy subjects and 11 subjects who had vascular disorders. In most cases, fluxes detected at both fiber distances showed very similar fluctuations. For each fiber separation, flux values of healthy subjects and patients were not significantly different. Furthermore, skin temperature (range: 22-34 degrees C) influenced the toe's pulp microcirculation markedly, increasing similarly at both probe separations, with a higher flux at a separation of 1.0 mm than at 0.2 mm. The flux ratio signal, obtained by dividing the flux at 0.2 mm by the flux at 1.0 mm, was significantly different between the two groups (p &< 0.05). In conclusion, the flux detected in vivo by means of LDPM, is influenced by the distance between the optical fibers. Use of the flux ratio with a multiseparation probe deserves attention as it is a possible marker for discriminating normal tissue perfusion from pathological skin tissue perfusion, independently from tissue temperature.

Adult↗