PubMed Health⌕ Search

Biomedical subjects

Ferran Reverter

Publications and source records attributed to Ferran Reverter.

2 recordsLinked to original sources

A framework for block-wise missing data in multi-omics.

High-throughput technologies have generated vast amounts of omic data. It is a consensus that the integration of diverse omics sources improves predictive models and biomarker discovery. However, managing multiple omics data poses challenges such as data heterogeneity, noise, high-dimensionality and missing data, especially in block-wise patterns. This study addresses the challenges of high dimensionality and block-wise missing data through a regularization and constrained-based approach. The methodology is implemented in the R package bwm for binary and continuous response variables, and applied to breast cancer and exposome multi-omics datasets, achieving strong performance even in scenarios with missing data present in all omics. In binary classification task, our proposed model achieves accuracy in the range of 86% to 92%, and F1 in the range of 68% to 79%. And, in regression task the correlation between true and predicted responses is in the range of 72% to 76%. However, there is a slight decline in performance metrics as the percentage of missing data increases. In scenarios where block-wise missing data affects multiple omics, the model performance actually surpasses that of scenarios where missing data is present in only one omics. One possible explanation for this might be that the other scenarios introduce a greater diversity of observation profiles, leading to a more robust model. Depending on the specific omics being studied, there is greater consistency in feature selection when comparing block-wise missing data scenarios.

Humans↗

Baseline concentrations of trace elements in surface soils of the Torrelles and Sant Climent Municipal Districts (Catalonia, Spain).

An investigation was conducted to study the baseline levels of Ba, Cd, Cu, Cr, Ni, Pb, Sr, V and Zn (aqua regia-extractable) based on 51 representative soils of the Torrelles and Sant Climent Municipal Districts (Catalonia, Spain). The baseline concentrations of those elements were (mg kg(-1)): Ba 73.9-617.9, Cr 9.2-120.2, Cu 4.0-111.6, Ni 6.1-118.6, Pb 5.6-217.5, Sr 19.6-128.8, V 12.1-101.2, and Zn 16.8-326.8, respectively. Forty-nine samples were reported as having less than the 0.67 mg kg(-1) detection limit for cadmiun and were therefore not useful for baseline determination; however, these results suggest that the baseline average is probably below 0.67 mg kg(-1). Upper baseline values for most of the elements corresponded with those reported in the literature, except for Pb and Zn, which were two to four times greater. Soil properties, including clay fraction, OC, CEC and pH(w) were related to metal concentration using correlation and factorial analysis. R-mode factor analysis separates the soil analysis data into three factors. These factors explain 67.3% of the total variance, suggesting that metal concentration was controlled by soil composition.

Aluminum Silicates↗