Assay using succinyldithiocholine as substrate: the method of choice for the measurement of cholinesterase catalytic activity in serum to diagnose succinyldicholine sensitivity.

No comparative information is available concerning the ability of various cholinesterase (ChE) methods to identify succinyldicholine-sensitive patients, purely on the basis of the enzyme activity recorded in serum. Here, we evaluated six different methods for the measurement of ChE activity; 131 subjects were subdivided according to ChE phenotype and, therefore, to succinyldicholine sensitivity. ChE phenotype was determined by measuring dibucaine and fluoride numbers. DNA analysis was also performed to confirm correlation between the phenotype classification used in the study and the ChE genotype. The tested methods were significantly different in their ability to discriminate between the subjects with and without succinyldicholine-sensitive phenotypes. The succinyldithiocholine/5,5'-dithio-bis(2-nitrobenzoate) (DTNB) method showed the highest accuracy (area under the receiver operating characteristic (ROC) curve 0.97) followed by the propionylthiocholine/DTNB method (area under the ROC curve 0.94). On the other hand, the two methods using butyrylthiocholine as substrate and that employing benzoylcholine showed limited clinical utility in discriminating subjects at risk of prolonged apnea (area under the ROC curve < or = 0.9). Using the succinyldithiocholine method, a value < or = 23 U/l was approximately five times as likely to occur in a sensitive individual as in a normal one.

Anesthetics, Local↗

Recommendations for the routine use of pancreatic amylase measurement instead of total amylase for the diagnosis and monitoring of pancreatic pathology.

This document reviews the scientific evidence expected to persuade clinical laboratories to substitute pancreatic amylase measurement for total amylase in cases of suspected pancreatic pathology. A substantial evidence is now available to support such change. The measurement of pancreatic amylase in serum is: 1. more sensitive and specific for the detection of pancreatic tissue damage than that of the total enzyme activity, 2. easy and quick to perform in emergency conditions, 3. analytically precise in relation to its clinical application, 4. suitable for easy transfer and comparison of results from different care delivery units, and 5. characterized by well-defined decision limits for the diagnosis of acute pancreatitis.

Acute Disease↗

Intermethod variation in serum carcinoembryonic antigen (CEA) measurement. fresh serum pools and control materials compared.

This study was undertaken to evaluate the feasibility of using commercial control materials in a regional external quality assessment scheme (EQAS) for serum carcinoembryonic antigen (CEA) measurement. We have assessed the commutability of 12 commercial control materials using five automated immunochemical systems. We compared the intermethod behavior of the materials with that of 12-14 patient serum pools. In a total of 48 comparisons (12 materials x 4 pairs of analytical systems), seven instances of non-commutability were apparent, as shown by normalized residuals falling outside the +/-3 interval. The use of non-commutable materials generates two negative effects. In EQAS, the interlaboratory variation recorded is not representative of the variation expected in the assay of patient sera; in interlaboratory harmonization programs, recalibration with non-commutable materials increases, instead of decreasing, the interlaboratory variation. Both these effects were shown to occur in CEA measurement with the tested materials and systems. The materials planned to be used in our EQAS turned out to be commutable: this gave us the guarantee of measuring realistic interlaboratory variation values, although the check for commutability should be extended to all the analytical systems used by the participants in the scheme.

Calibration↗

A two-center evaluation of the blood gas immediate response mobile analyzer (IRMA).

The Immediate Response Mobile Analyzer (IRMA) is a selective and portable point-of-care testing (POCT) blood gas, electrolyte and hematocrit (Hct) analyzer. The overall analytical performance was evaluated in a two-center study involving two Italian hospital laboratories, following the guidelines suggested by the manufacturer (based on the NCCLS protocol), after a preliminary evaluation of their formal validity. The IRMA was compared to the analyzers used in the routine laboratory as reference. The considered parameters were pH, pO2, pCO2, Na+, K+, ionized calcium and Hct. When using the aqueous quality control material provided by the manufacturer most of the parameters showed good precision, with the exception of pCO2 and pO2 that showed high CVs on two of the three levels of the aqueous control. We could demonstrate that this imprecision was material-related and was reduced when using a different material (blood equilibrated by tonometry). With tonometred blood for pO2 and pCO2 and the aqueous material for the remaining parameters the CVs were all below 5%, ranging from 0.08% to 2.8%. The IRMA results correlated adequately with the comparison instruments, with the exception of sodium and ionized calcium where contradictory results were obtained in the two centers.

Blood Gas Analysis↗

IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C. Part 1. The concept of reference procedures for the measurement of catalytic activity concentrations of enzymes.

This paper is the first in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C and with the certification of reference preparations. Other parts deal with: Part 2. Reference Procedure for the Measurement of Catalytic Concentration of Creatine Kinase; Part 3. Reference Procedure for the Measurement of Catalytic Concentration of Lactate Dehydrogenase; Part 4. Reference Procedure for the Measurement of Catalytic Concentration of Alanine Aminotransferase; Part 5. Reference Procedure for the Measurement of Catalytic Concentration of Aspartate Aminotransferase; Part 6. Reference Procedure for the Measurement of Catalytic fication of Four Reference Materials for the Determination of Enzymatic Activity of y-Glutamyltransferase, Lactate Dehydrogenase, Alanine Aminotransferase and Creatine Kinase at 37 degrees C. A document describing the determination of preliminary reference values is also in preparation.

Catalysis↗

IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C. Part 2. Reference procedure for the measurement of catalytic concentration of creatine kinase.

This paper is the second in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C and the certification of reference preparations. Other parts deal with: Part 1. The Concept of Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes; Part 3. Reference Procedure for the Measurement of Catalytic Concentration of Lactate Dehydrogenase; Part 4. Reference Procedure for the Measurement of Catalytic Concentration of Alanine Aminotransferase; Part 5. Reference Procedure for the Measurement of Catalytic Concentration of Aspartate Aminotransferase; Part 6. Reference Procedure for the Measurement of Catalytic Concentration of gamma-Glutamyltransferase; Part 7. Certification of Four Reference Materials for the Determination of Enzymatic Activity of gamma-Glutamyltransferase, Lactate Dehydrogenase, Alanine Aminotransferase and Creatine Kinase at 37 degrees C. A document describing the determination of preliminary reference values is also in preparation. The pro- described 30 degrees C IFCC reference method (1). Differences are tabulated and commented on in Appendix 3.

Body Temperature↗

IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C. Part 3. Reference procedure for the measurement of catalytic concentration of lactate dehydrogenase.

This paper is the third in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C and the certification of reference preparations. Other parts deal with: Part 1. The Concept of Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes; Part 2. Reference Procedure for the Measurement of Catalytic Concentration of Creatine Kinase; Part 4. Reference Procedure for the Measurement of Catalytic Concentration of Alanine Aminotransferase; Part 5. Reference Procedure for the Measurement of Catalytic Concentration of Aspartate Aminotransferase; Part 6. Reference Procedure for the Measurement of Catalytic Concentration of gamma-Glutamyltransferase; Part 7. Certification of Four Reference Materials tamyltransferase, Lactate Dehydrogenase, Alanine Aminotransferase and Creatine Kinase at 37 degrees C. A document describing the determination of preliminary upper reference limits is also in preparation. The procedure described here is deduced from the previously described 30 degrees C IFCC reference method (1). Differences are tabulated and commented on in Appendix 1.

Body Temperature↗

IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C. International Federation of Clinical Chemistry and Laboratory Medicine. Part 4. Reference procedure for the measurement of catalytic concentration of alanine aminotransferase.

This paper is the fourth in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C and the certification of reference preparations. Other parts deal with: Part 1. The Concept of Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes; Part 2. Reference Procedure for the Measurement of Catalytic Concentration of Creatine Kinase; Part 3. Reference Procedure for the Measurement of Catalytic Concentration of Lactate Dehydrogenase; Part 5. Reference Procedure for the Measurement of Catalytic Concentration of Aspartate Aminotransferase; Part 6. Reference Procedure for the Measurement of Catalytic Concentration of Gamma-Glutamyltransferase; Part 7. Certification of Four Reference Materials for the Determination of Enzymatic Activity of Gamma-Glutamyltransferase, Lactate Dehydrogenase, Alanine Aminotransferase and Creatine Kinase at 37 degrees C. A document describing the determination of preliminary upper reference limits is also in preparation. The procedure described here is deduced from the previously described 30 degrees C IFCC reference method. Differences are tabulated and commented on in Appendix 2.

Alanine Transaminase↗

IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C. International Federation of Clinical Chemistry and Laboratory Medicine. Part 5. Reference procedure for the measurement of catalytic concentration of aspartate aminotransferase.

This paper is the fifth in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C and the certification of reference preparations. Other parts deal with: Part 1. The Concept of Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes; Part 2. Reference Procedure for the Measurement of Catalytic Concentration of Creatine Kinase; Part 3. Reference Procedure for the Measurement of Catalytic Concentration of Lactate Dehydrogenase; Part 4. Reference Procedure for the Measurement of Catalytic Concentration of Alanine Aminotransferase; Part 6. Reference Procedure for the Measurement of Catalytic Concentration of Gamma-Glutamyltransferase; Part 7. Certification of Four Reference Materials for the Determination of Enzymatic Activity of Gamma-Glutamyltransferase, Lactate Dehydrogenase, Alanine Aminotransferase and Creatine Kinase at 37 degrees C. A document describing the determination of preliminary upper reference limits is also in preparation. The procedure described here is deduced from the previously described 30 degrees C IFCC reference method. Differences are tabulated and commented on in Appendix 3.

Aspartate Aminotransferases↗

IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C. International Federation of Clinical Chemistry and Laboratory Medicine. Part 6. Reference procedure for the measurement of catalytic concentration of gamma-glutamyltransferase.

This paper is the sixth in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C and the certification of reference preparations. Other parts deal with: Part 1. The Concept of Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes; Part 2. Reference Procedure for the Measurement of Catalytic Concentration of Creatine Kinase; Part 3. Reference Procedure for the Measurement of Catalytic Concentration of Lactate Dehydrogenase; Part 4. Reference Procedure for the Measurement of Catalytic Concentration of Alanine Aminotransferase; Part 5. Reference Procedure for the Measurement of Catalytic Concentration of Aspartate Aminotransferase; Part 7. Certification of Four Reference Materials for the Determination of Enzymatic Activity of Gamma-Glutamyltransferase, Lactate Dehydrogenase, Alanine Aminotransferase and Creatine Kinase at 37 degrees C A document describing the determination of preliminary upper reference limits is also in preparation. The procedure described here is deduced from the previously described 30 degrees C IFCC reference method. Differences are tabulated and commented on in Appendix 1.

Catalysis↗

IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C. International Federation of Clinical Chemistry and Laboratory Medicine. Part 7. Certification of four reference materials for the determination of enzymatic activity of gamma-glutamyltransferase, lactate dehydrogenase, alanine aminotransferase and creatine kinase accord.

This paper is the seventh in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C and the certification of reference preparations. Other parts deal with: Part 1. The Concept of Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes; Part 2. Reference Procedure for the Measurement of Catalytic Concentration of Creatine Kinase; Part 3. Reference Procedure for the Measurement of Catalytic Concentration of Lactate Dehydrogenase; Part 4. Reference Procedure for the Measurement of Catalytic Concentration of Alanine Aminotransferase; Part 5. Reference Procedure for the Measurement of Catalytic Concentration of Aspartate Aminotransferase; Part 6. Reference Procedure for the Measurement of Catalytic Concentration of Gamma-Glutamyltransferase. A document describing the determination of preliminary reference values is also in preparation. The certification of the catalytic activity concentrations as determined by the recently elaborated IFCC primary reference methods at 37 degrees C of four enzyme preparations, namely IRMM/IFCC 452 (gamma-glutamyltransferase), IRMM/IFCC 453 (lactate dehydrogenase 1), IRMM/IFCC 454 (alanine aminotransferase) and IRMM/IFCC 455 (creatine kinase) is described. Homogeneity data were derived from previous results. Stability was assessed using recently obtained data as well as data from previous stability studies. The collaborative study for value assignment was performed under a strict quality control scheme to ensure traceability to the primary reference method. Uncertainty of the materials was assessed in compliance with the Guide to the Expression of Uncertainty in Measurement. The certified values obtained at 37 degrees C are 1.90 microkat/l +/- 0.04 microkat/l (114.1 U/l +/- 2.4 U/l), for gamma-glutamyltransferase, 8.37 microkat/l +/- 0.12 microkat/l (502 U/l +/- 7 U/l), for lactate dehydrogenase 1, 3.09 microkat/l +/- 0.07 microkat/l (186 U/l +/- 4 U/l), for alanine aminotransferase and 1.68 microkat/l +/- 0.07 microkat/l (101 U/l +/- 4 U/l), for creatine kinase. The materials are intended for internal quality control as well as for the evaluation of test systems as required by recent European Union legislation. Furthermore, the materials can be used to transfer accuracy from a reference method to a routine procedure provided the procedures exhibit the same analytical specificity and the certified materials are commutable.

Alanine Transaminase↗

Errors in laboratory medicine.

BACKGROUND: The problem of medical errors has recently received a great deal of attention, which will probably increase. In this minireview, we focus on this issue in the fields of laboratory medicine and blood transfusion. METHODS: We conducted several MEDLINE queries and searched the literature by hand. Searches were limited to the last 8 years to identify results that were not biased by obsolete technology. In addition, data on the frequency and type of preanalytical errors in our institution were collected. RESULTS: Our search revealed large heterogeneity in study designs and quality on this topic as well as relatively few available data and the lack of a shared definition of "laboratory error" (also referred to as "blunder", "mistake", "problem", or "defect"). Despite these limitations, there was considerable concordance on the distribution of errors throughout the laboratory working process: most occurred in the pre- or postanalytical phases, whereas a minority (13-32% according to the studies) occurred in the analytical portion. The reported frequency of errors was related to how they were identified: when a careful process analysis was performed, substantially more errors were discovered than when studies relied on complaints or report of near accidents. CONCLUSIONS: The large heterogeneity of literature on laboratory errors together with the prevalence of evidence that most errors occur in the preanalytical phase suggest the implementation of a more rigorous methodology for error detection and classification and the adoption of proper technologies for error reduction. Clinical audits should be used as a tool to detect errors caused by organizational problems outside the laboratory.

Blood Transfusion↗