PubMed Health⌕ Search

Biomedical subjects

Filip Schutyser

Publications and source records attributed to Filip Schutyser.

8 recordsLinked to original sources

Assessment of bone segmentation quality of cone-beam CT versus multislice spiral CT: a pilot study.

OBJECTIVES: The objective of this study was to quantitatively assess the quality of jawbone models generated from cone beam computed tomography (CBCT) by comparison with similar models obtained from multislice spiral computed tomography (MSCT). MATERIAL AND METHODS: Three case studies were performed involving images of anthropomorphic head phantoms and real patients acquired with 3 CBCT (NewTom 9000 DVT, Accuitomo 3D, and i-CAT) and 2 MSCT scanners (Somatom VolumeZoom and Lightspeed). Bone was segmented from the CBCT and MSCT images using global thresholding. CBCT vs MSCT segmentation differences were assessed by comparing bone thickness measurements at anatomically corresponding sites, identified automatically by CBCT to MSCT image registration. RESULTS: There was a statistically significant difference between the MSCT and CBCT segmented bone thicknesses, varying from 0.05 +/- 0.47 mm (i-CAT) up to 1.2 +/- 1.00 mm (3D Accuitomo, posterior maxilla). CONCLUSIONS: An automated, reproducible, and observer-independent method has been developed to assess the quality of CBCT bone models using MSCT as a clinically established method of reference. Our validation method is generally applicable in cases where no geometric ground-truth is available.

Algorithms↗

State-of-the-art on cone beam CT imaging for preoperative planning of implant placement.

Orofacial diagnostic imaging has grown dramatically in recent years. As the use of endosseous implants has revolutionized oral rehabilitation, a specialized technique has become available for the preoperative planning of oral implant placement: cone beam computed tomography (CT). This imaging technology provides 3D and cross-sectional views of the jaws. It is obvious that this hardware is not in the same class as CT machines in cost, size, weight, complexity, and radiation dose. It is thus considered to be the examination of choice when making a risk-benefit assessment. The present review deals with imaging modalities available for preoperative planning purposes with a specific focus on the use of the cone beam CT and software for planning of oral implant surgery. It is apparent that cone beam CT is the medium of the future, thus, many changes will be performed to improve these. Any adaptation of the future systems should go hand in hand with a further dose optimalization.

Anatomy, Cross-Sectional↗

Three-dimensional cephalometry: spiral multi-slice vs cone-beam computed tomography.

Three-dimensional (3D) craniofacial imaging techniques are becoming increasingly popular and have opened new possibilities for orthodontic assessment, treatment, and follow-up. Recently, a new 3D cephalometric method based on spiral multi-slice (MS) computed tomography (CT) was developed and validated by our research group. This innovative 3D virtual approach is a bridge between conventional cephalometry and modern craniofacial imaging techniques and provides high-quality, accurate, and reliable quantitative 3D data. The aim of this article was to describe the advantages and the disadvantages of spiral MS-CT 3D cephalometry and to discuss the potential of cone-beam CT 3D cephalometry.

Cephalometry↗

A new method of 3-D cephalometry Part I: the anatomic Cartesian 3-D reference system.

The purpose of this study was to present a new innovative three-dimensional (3-D) cephalometric method. Part I deals with the set-up and validation of a voxel-based semi-automatic 3-D cephalometric reference system. The CT data (DICOM 3.0 files) of 20 control patients with normal skeletal relationships were used for this study. To investigate accuracy and reliability of the 3-D cephalometric reference system (Maxilimtrade mark, version 1.3.0) a total of 42 (14 horizontal, 14 vertical and 14 transversal) orthogonal measurements were performed on each patient twice by each of two investigators. The intra-observer measurement error was less then 0.88 mm, 0.76 mm and 0.84 mm for horizontal, vertical and transversal orthogonal measurements, respectively. The inter-observer measurement error was less as 0.78 mm, 0.86 mm and 1.26 mm for horizontal, vertical and transversal orthogonal measurements, respectively. Squared correlation coefficients showed a high intra-observer and inter-observer reliability. The presented 3-D cephalometric reference system proved to be accurate and reliable and can therefore be used for 3-D cephalometric hard and soft tissue analysis.

Adolescent↗

Robust visualization of the dental occlusion by a double scan procedure.

A detailed visualization of the dental occlusion in 3D image-based planning environments for oral and maxillofacial planning is important. With CT imaging however, this occlusion is often deteriorated by streak artifacts caused by amalgam fillings. Moreover, more detailed surface information at the level of the dental cuspids is often desired. In this paper, a double scan technique is introduced to image the dental occlusion by means of a newly designed 3D splint. The patient wears this splint between the upper and lower teeth during CT-scan. In a second step, the splint is positioned between the plaster casts of the upper and lower jaw, and this setup is scanned. Based on markers in the 3D splint, both data sets are fused and a combined visualization is possible. The accuracy, robustness and applicability in clinical routine is shown. This technology enables meticulous 3D cephalometric analysis, detailed maxillofacial planning and opens possibilities towards intraoperative support.

Cadaver↗

A computed tomographic scan-derived customized surgical template and fixed prosthesis for flapless surgery and immediate loading of implants in fully edentulous maxillae: a prospective multicenter study.

BACKGROUND: Based on three-dimensional implant planning software for computed tomographic (CT) scan data, customized surgical templates and final dental prostheses could be designed to ensure high precision transfer of the implant treatment planning to the operative field and an immediate rigid splinting of the installed implants, respectively. PURPOSE: The aim of the present study was to (1) evaluate a concept including a treatment planning procedure based on CT scan images and a prefabricated fixed prosthetic reconstruction for immediate function in upper jaws using a flapless surgical technique and (2) validate the universality of this concept in a prospective multicenter clinical study. MATERIALS AND METHODS: Twenty-seven consecutive patients with edentulous maxillae were included. Treatments were performed according to the Teeth-in-an-Hour concept (Nobel Biocare AB, Göteborg, Sweden), which includes a CT scan-derived customized surgical template for flapless surgery and a prefabricated prosthetic suprastructure. RESULTS: All patients received their final prosthetic restoration immediately after implant placement, that is, both the surgery and the prosthesis insertion were completed within approximately 1 hour. In the 24 patients followed for 1 year, all prostheses and individual implants were recorded as stable. CONCLUSION: The present prospective multicenter study indicates that the prefabrication, on the basis of models derived from three-dimensional oral implant planning software, of both surgical templates for flapless surgery and dental prostheses for immediate loading is a very reliable treatment option. It is evident that the same approach could be used for staged surgery and in partial edentulism.

Adult↗

Accuracy of drilling guides for transfer from three-dimensional CT-based planning to placement of zygoma implants in human cadavers.

The accuracy of surgical drilling guides was assessed for placement of zygoma implants. Six zygoma fixtures of length 45 mm (Nobel Biocare, Göteborg, Sweden) were placed in three formalin-fixed human cadavers using surgical drilling guides. The fabrication of these custom-made drilling guides was based on three-dimensional computerized tomography (3D-CT) data for the maxillary-zygomatic complex. The installation of the implants was simulated preoperatively using an adopted 3D-CT planning system. In addition, anatomical measurements of the zygomatic bone were performed on the 3D images. The preoperative CT images were then matched with postoperative ones in order to assess the deviation between the planned and installed implants. The angle between the planned and actually placed implants was < 3 degrees in four out of six cases. The largest deviation found at the exit point of one of the six implants was 2.7 mm. The present study showed that the use of surgical drilling guides should be encouraged for zygoma implant placement because of the lengths of the implants involved and the anatomical intricacies of the region.

Adult↗

Image-based planning and validation of C1-C2 transarticular screw fixation using personalized drill guides.

OBJECTIVE: Posterior transarticular spine fusion is a surgical procedure used to stabilize the cervical bodies C1 and C2. Currently, spine screws are used most frequently, according to the procedure of Magerl. As the anatomy is rather complex and the view is limited, this procedure has a high risk factor. We present and validate a planning system for cervical screw insertion based on preoperative CT imaging. MATERIALS AND METHODS: The planning system discussed allowed a neurosurgeon to interactively determine the desired position of the cervical screws, based on appropriate and real-time reslices through the preoperative CT image volume. From the planning, a personalized mechanical drill guide was derived as a means of transferring the plan intraoperatively. Eight cadaver experiments were performed to validate this approach. Postoperative CT was applied, and screw locations were extracted from the postoperative images after registering them to preoperative images. In this way, the deviations of the axes of the planned and inserted screws were determined. RESULTS: From an initial cadaver series, it was observed that the drill guides were not stable enough to cope with the drilling forces, and tended to become displaced. Still, most of the inserted screws were reported to be placed adequately. No vascular compromise or invasion of the spinal canal was observed. For a second cadaver series, the design of the drill guide was altered. In this series, the displacement was no longer present, and all screws were optimally placed. CONCLUSIONS: The preoperative planning system allowed the neurosurgeon to rehearse screw insertion in a way that is closer to surgical reality. The image-based validation technique allowed verification and enhancement of the template design on a cadaver study, giving accuracies comparable to those obtained with transfer by navigation.

Bone Screws↗