Pre-operative computed tomography coronary angiography to detect significant coronary artery disease in patients referred for cardiac valve surgery.

OBJECTIVES: We studied the diagnostic performance of 64-slice computed tomography coronary angiography (CTCA) to rule out or detect significant coronary stenosis in patients referred for valve surgery. BACKGROUND: Invasive conventional coronary angiography (CCA) is recommended in most patients scheduled for valve surgery. METHODS: During a 6-month period, 145 patients were prospectively identified from a consecutive patient population scheduled for valve surgery. Thirty-five patients were excluded because of CTCA criteria: irregular heart rhythm (n = 26), impaired renal function (n = 5), and known contrast allergy (n = 4). General exclusion criteria were: hospitalization in community hospital (n = 4), no need for CCA (n = 4), previous coronary artery bypass surgery (n = 1), or percutaneous coronary intervention (n = 4). Of the remaining 97 patients, 27 denied written informed consent. Thus, the study population comprised 70 patients (49 male, 21 female; mean age 63 +/- 11 years). RESULTS: Prevalence of significant coronary artery disease, defined as having at least 1 > or =50% stenosis per patient, was 25.7%. Beta-blockers were administered in 71%, and 64% received lorazepam. The mean heart rate dropped from 72.5 +/- 12.4 to 59.5 +/- 7.5 beats/min. The mean scan time was 12.8 +/- 1.3 s. On a per-patient analysis, the sensitivity, specificity, and positive and negative predictive values were: 100% (18 of 18; 95% confidence interval [CI] 78 to 100), 92% (48 of 52; 95% CI 81 to 98), 82% (18 of 22; 95% CI 59 to 94), and 100% (48 of 48; 95% CI 91 to 100), respectively. CONCLUSIONS: The diagnostic accuracy of 64-slice CTCA for ruling out the presence of significant coronary stenoses in patients undergoing valve surgery is excellent and allows CTCA implementation as a gatekeeper for invasive CCA in these patients.

Adrenergic beta-Antagonists↗

Multislice spiral computed tomography for the evaluation of stent patency after left main coronary artery stenting: a comparison with conventional coronary angiography and intravascular ultrasound.

BACKGROUND: Surveillance conventional coronary angiography (CCA) is recommended 2 to 6 months after stent-supported left main coronary artery (LMCA) percutaneous coronary intervention due to the unpredictable occurrence of in-stent restenosis (ISR), with its attendant risks. Multislice computed tomography (MSCT) is a promising technique for noninvasive coronary evaluation. We evaluated the diagnostic performance of high-resolution MSCT to detect ISR after stenting of the LMCA. METHODS AND RESULTS: Seventy-four patients were prospectively identified from a consecutive patient population scheduled for follow-up CCA after LMCA stenting and underwent MSCT before CCA. Until August 2004, a 16-slice scanner was used (n = 27), but we switched to the 64-slice scanner after that period (n = 43). Patients with initial heart rates > 65 bpm received beta-blockers, which resulted in a mean periscan heart rate of 57 +/- 7 bpm. Among patients with technically adequate scans (n = 70), MSCT correctly identified all patients with ISR (10 of 70) but misclassified 5 patients without ISR (false-positives). Overall, the accuracy of MSCT for detection of angiographic ISR was 93%. The sensitivity, specificity, and positive and negative predictive values were 100%, 91%, 67%, and 100%, respectively. When analysis was restricted to patients with stenting of the LMCA with or without extension into a single major side branch, accuracy was 98%. When both branches of the LMCA bifurcation were stented, accuracy was 83%. For the assessment of stent diameter and area, MSCT showed good correlation with intravascular ultrasound (r = 0.78 and 0.73, respectively). An intravascular ultrasound threshold value > or = 1 mm was identified to reliably detect in-stent neointima hyperplasia with MSCT. CONCLUSIONS: Current MSCT technology, in combination with optimal heart rate control, allows reliable noninvasive evaluation of selected patients after LMCA stenting. MSCT is safe to exclude left main ISR and may therefore be an acceptable first-line alternative to CCA.

Adrenergic beta-Antagonists↗

Use of 64-slice CT in symptomatic patients after coronary bypass surgery: evaluation of grafts and coronary arteries.

AIMS: Although previous generations of multislice computed tomography (CT) have demonstrated accurate detection of obstructive bypass graft disease, progression of coronary disease is a more frequent cause for ischaemic symptoms late after bypass graft surgery. We explored the diagnostic performance of 64-slice CT in symptomatic patients after bypass surgery, for the assessment of both grafts and native coronary arteries. METHODS AND RESULTS: The 64-slice CT angiography (Siemens Sensation 64, Germany) was performed in 52 symptomatic patients, 10 +/- 5 years after bypass surgery. Two independent, blinded observers assessed all grafts and coronary arteries for stenosis, using conventional quantitative angiography as a reference. A total of 109 grafts (182 graft segments), 123 distal coronary run-offs, and 116 non-bypassed coronary branches (288 segments) were analysed. Per-segment detection of graft disease yielded a sensitivity of 99% (71/72) and specificity of 96% (106/110). Sensitivity and specificity to detect run-off disease were 89% (8/9) and 93% (106/114), positive predictive value was 50% (8/16). In non-grafted coronary segments, CT detected significant stenosis with a sensitivity and specificity of 97% (62/64) and 86% (192/224). Overestimation occurred more frequently in calcified segments (P = 0.002). CONCLUSION: The 64-slice CT allows angiographic evaluation of grafts and coronary arteries, although overestimation of coronary obstruction occurs, particularly in the presence of calcified disease.

Aged↗

Plaque sealing: are the benefits outweighing the risks?

A 36-year-old man was admitted with reported short attacks of acute chest pain with small increment of troponin and CK-MB and normal ECG. The 64-slice CT coronary angiography revealed a large non-obstructing non-calcified plaque in the proximal left anterior descending artery with positive vessel remodeling. The conventional coronary angiogram was normal but the intravascular ultrasound confirmed the CT findings. A drug eluting stent was implanted to seal the plaque. During the procedure, myocardial damage had occurred. At 6-month follow-up, 64-slice CT revealed minimal in-stent hyperplasia, which was confirmed at conventional angiography.

Adult↗

Multislice computed tomography and magnetic resonance imaging for the assessment of reperfused acute myocardial infarction.

OBJECTIVES: We evaluated the accuracy of in vivo delayed-enhancement multislice computed tomography (DE-MSCT) and delayed-enhancement magnetic resonance imaging (DE-MRI) for the assessment of myocardial infarct size using postmortem triphenyltetrazolium chloride (TTC) pathology as standard of reference. BACKGROUND: The diagnostic value of DE-MSCT for the assessment of acute reperfused myocardial infarction is currently unclear. METHODS: In 10 domestic pigs (25 to 30 kg), the circumflex coronary artery was balloon-occluded for 2 h followed by reperfusion. After 5 days (3 to 7 days), DE-MRI (1.5-T) was performed 15 min after administration of 0.2 mmol/kg gadolinium-DTPA using an inversion recovery gradient echo technique. On the same day, DE-MSCT (64-slice) was performed 15 min after administration of 1 gI/kg of iodinated contrast material. One day after imaging, hearts were excised, sectioned in 8 mm short-axis slices, and stained with TTC. Infarct size was defined as the hyperenhanced area on DE-MSCT and DE-MRI images and the TTC-negative area on TTC pathology slices. Infarct size was expressed as percentage of total slice area. RESULTS: Infarct size determined by DE-MSCT and DE-MRI showed a good correlation with infarct size assessed with TTC pathology (R2 = 0.96 [p < 0.001] and R(2) = 0.93 [p < 0.001], respectively). The correlation between DE-MSCT and DE-MRI was also good (R2 = 0.96; p < 0.001). The relative difference in CT attenuation value of infarcted myocardium compared to remote myocardium was 191 +/- 18%. The relative MR signal intensity between infarcted myocardium and remote myocardium was 554 +/- 156%. CONCLUSIONS: We demonstrated that DE-MSCT can assess acute reperfused myocardial infarction in good agreement with in vivo DE-MRI and TTC pathology.

Animals↗

The effect of open lung ventilation on right ventricular and left ventricular function in lung-lavaged pigs.

INTRODUCTION: Ventilation according to the open lung concept (OLC) consists of recruitment maneuvers, followed by low tidal volume and high positive end-expiratory pressure, aiming at minimizing atelectasis. The minimization of atelectasis reduces the right ventricular (RV) afterload, but the increased intrathoracic pressures used by OLC ventilation could increase the RV afterload. We hypothesize that when atelectasis is minimized by OLC ventilation, cardiac function is not affected despite the higher mean airway pressure. METHODS: After repeated lung lavage, each pig (n = 10) was conventionally ventilated and was ventilated according to OLC in a randomized cross-over setting. Conventional mechanical ventilation (CMV) consisted of volume-controlled ventilation with 5 cmH2O positive end-expiratory pressure and a tidal volume of 8-10 ml/kg. No recruitment maneuvers were performed. During OLC ventilation, recruitment maneuvers were applied until PaO2/FiO2 > 60 kPa. The peak inspiratory pressure was set to obtain a tidal volume of 6-8 ml/kg. The cardiac output (CO), the RV preload, the contractility and the afterload were measured with a volumetric pulmonary artery catheter. A high-resolution computed tomography scan measured the whole lung density and left ventricular (LV) volumes. RESULTS: The RV end-systolic pressure-volume relationship, representing RV afterload, during steady-state OLC ventilation (2.7 +/- 1.2 mmHg/ml) was not significantly different compared with CMV (3.6 +/- 2.5 mmHg/ml). Pulmonary vascular resistance (OLC, 137 +/- 49 dynes/s/cm5 versus CMV, 130 +/- 34 dynes/s/cm5) was comparable between groups. OLC led to a significantly lower amount of atelectasis (13 +/- 2% of the lung area) compared with CMV (52 +/- 3% of the lung area). Atelectasis was not correlated with pulmonary vascular resistance or end-systolic pressure-volume relationship. The LV contractility and afterload during OLC was not significantly different compared with CMV. Compared with baseline, the LV end-diastolic volume (66 +/- 4 ml) decreased significantly during OLC (56 +/- 5 ml) ventilation and not during CMV (61 +/- 3 ml). Also, CO was significantly lower during OLC ventilation (OLC, 4.1 +/- 0.3 l/minute versus CMV, 4.9 +/- 0.3 l/minute). CONCLUSION: In this experimental study, OLC resulted in significantly improved lung aeration. Despite the use of elevated airway pressures, no evidence was found for a negative effect of OLC on RV afterload or LV afterload, which might be associated with a loss of hypoxic pulmonary vasoconstriction due to alveolar recruitment. The reductions in the CO and in the mean pulmonary artery pressure were consequences of a reduced preload.

Animals↗

Noninvasive detection of subclinical coronary atherosclerosis coupled with assessment of changes in plaque characteristics using novel invasive imaging modalities: the Integrated Biomarker and Imaging Study (IBIS).

OBJECTIVES: Our purpose was to assess noninvasive imaging in detection of subclinical atherosclerosis and to examine novel invasive modalities to describe prevalence and temporal changes in putative characteristics of "high-risk" plaques. BACKGROUND: Conventional coronary imaging cannot identify "high-risk" lesions. METHODS: Conventional (quantitative angiography and intravascular ultrasound [IVUS]) and novel imaging (IVUS-based palpography and gray scale echogenicity) were performed at baseline and 6 months later in 67 patients with diverse clinical presentations. Different imaging techniques were compared within a common segment defined by multislice computed tomography (MSCT). RESULTS: Compared with IVUS, the sensitivity, specificity, and positive and negative predictive value of MSCT for detecting significant plaque was 86%, 69%, 90%, and 61%, respectively. In coronary arteries with <50% stenosis, there were no temporal changes in luminal and plaque dimensions measured by quantitative coronary angiography or IVUS; however, a significant reduction in abnormal strain pattern was detected on palpography (density high strain spots/cm: 1.6 +/- 1.5 vs. 1.2 +/- 1.4, p = 0.0123. These changes were mainly related to significant changes in patients who presented with ST-segment elevation myocardial infarction. The assessment of plaque echogenicity showed no temporal changes. There were no correlations between circulating biomarkers and quantifiable imaging parameters. CONCLUSIONS: Mild angiographic disease is associated with large atherosclerotic plaques on MSCT. Conventional invasive coronary imaging reveals static luminal and plaque dimensions on standard medical therapy with plaque hypoechogenicity remaining unchanged over the 6-month period. By contrast, palpography measurements of strain correlate with clinical presentation and significantly decrease on standard medical therapy. Novel imaging modalities, such as palpography, might provide insights into plaque biology and might eventually serve as intermediate end points in interventional trials.

Coronary Angiography↗

Prediction of left ventricular function after drug-eluting stent implantation for chronic total coronary occlusions.

OBJECTIVES: We studied the effect of drug-eluting stent implantation for chronic total coronary occlusion (CTO) on left ventricular volumes and function and assessed the predictive value of magnetic resonance imaging (MRI) performed before revascularization. BACKGROUND: The effect of recanalization of CTO on long-term left ventricular function and the value of myocardial viability assessment with MRI is incompletely understood. METHODS: Twenty-seven patients underwent contrast-enhanced MRI before and five months after successful drug-eluting stent implantation for CTO. A CTO was defined as a complete occlusion of a major epicardial coronary artery existing for at least six weeks (mean, 7 +/- 5 months). Myocardial wall thickening and left ventricular volumes were quantified on cine-images, and the transmural extent of infarction (TEI) was scored on delayed-enhancement images. RESULTS: A significant decrease in mean end-systolic volume index (34 +/- 13 ml/m2 to 31 +/- 13 ml/m2; p = 0.02) and mean end-diastolic volume index (84 +/- 15 ml/m2 to 79 +/- 15 ml/m2; p < 0.002) was observed, whereas the mean ejection fraction did not change significantly (61 +/- 9% to 62 +/- 11%; p = 0.54). The extent of the left ventricle that was dysfunctional but viable before revascularization was related to improvement in end-systolic volume index (R = 0.46; p = 0.01) and ejection fraction (R = 0.49; p = 0.01) but not to the end-diastolic volume index (R = 0.10; p = 0.53). Segmental wall thickening improved significantly in segments with <25% TEI (21 +/- 15% to 35 +/- 25%; p < 0.001), tended to improve in segments with 25% to 75% TEI (18 +/- 22% to 27 +/- 22%; p = 0.10), whereas segments with >75% TEI did not improve (4 +/- 14% to -9 +/- 14%; p = 0.54). CONCLUSIONS: Drug-eluting stent implantation for a CTO has a beneficial effect on left ventricular volumes and function that can be predicted by performing MRI before revascularization.

Angioplasty, Balloon, Coronary↗

Do risk factors influence the diagnostic accuracy of noninvasive coronary angiography with multislice computed tomography?

BACKGROUND: Multislice computed tomography (MSCT) is a relatively new noninvasive imaging modality in the evaluation of patients with suspected coronary artery disease (CAD). Whether diagnostic accuracy is influenced by gender or risk factors for CAD is currently unknown and was evaluated in this study. METHODS AND RESULTS: In 197 patients (171 men and 26 women; mean age, 60 +/- 11 years) 16-slice MSCT was performed and compared with invasive coronary angiography at 2 different centers (Leiden and Rotterdam, The Netherlands). Diagnostic accuracy for the detection of 50% luminal narrowing or greater was calculated for all patients combined, as well as for patients with known versus suspected CAD. In addition, diagnostic accuracy was determined in men versus women and in different subsets of patients based on the presence of risk factors for CAD including hypertension, type 2 diabetes mellitus, hypercholesterolemia, and obesity. Only segments with a diameter of 2.0 mm or greater were evaluated, whereas smaller segments and stents were excluded from the analysis. Overall, a sensitivity and specificity of 99% and 86%, respectively, on a patient level were demonstrated, with corresponding positive and negative predictive values of 95% and 96%, respectively. Similar values were observed in the different subsets of patients, with no statistical differences. CONCLUSION: These findings confirm the high diagnostic accuracy of MSCT, regardless of gender or risk factors.

Aged↗

High iodine concentration contrast material for noninvasive multislice computed tomography coronary angiography: iopromide 370 versus iomeprol 400.

OBJECTIVE: The objective of this study was to compare intracoronary attenuation on 16-row multislice computed tomography (16-MSCT) coronary angiography using 2 contrast materials (CM) with high iodine concentration. MATERIAL AND METHODS: Forty consecutive patients (29 male, 11 female; mean age, 61+/-11 years) with suspected coronary artery disease were randomized to 2 groups to receive 100 mL of either iopromide 370 (group 1: Ultravist 370, 370 mg iodine/mL; Schering AG, Berlin, Germany) or iomeprol 400 (group 2: Iomeron 400, 400 mg iodine/mL; Bracco Imaging SpA, Milan, Italy). Both CM were administered at a rate of 4 mL/s. All patients underwent 16-MSCT coronary angiography (Sensation 16; Siemens, Germany) with collimation 16 x 0.75 mm and rotation time 375 ms. The attenuation in Hounsfield units (HU) achieved after each CM was determined at regions of interest (ROIs) placed at the origin of coronary arteries and on the ascending aorta, descending aorta, and pulmonary artery. Differences in mean attenuation in the coronary arteries and on the ascending aorta, descending aorta, and pulmonary artery were evaluated using Student t test. RESULTS: The mean attenuation achieved at each anatomic site was consistently greater after iomeprol 400 than after iopromide 370. At the origin of coronary arteries, the mean attenuation after iomeprol 400 (340+/-53 HU) was greater (P<0.05) than that after iopromide 370 (313+/- 42 HU). Similar findings were noted for the mean attenuation in the ascending aorta, descending aorta, and pulmonary artery. CONCLUSION: The intravenous administration of iomeprol 400 provides higher attenuation of the coronary arteries and of the great arteries of the thorax as compared with iopromide 370 using the same injection parameters.

Adult↗

Automatic quantitative left ventricular analysis of cine MR images by using three-dimensional information for contour detection.

The purpose of this study was to evaluate an automatic boundary detection algorithm of the left ventricle on magnetic resonance (MR) short-axis images with the essential restriction of no manual corrections. The study comprised 13 patients (nine men, four women) and 12 healthy volunteers (11 men, one woman), and institutional review board approval and informed consent were obtained. The outline of the left ventricle was indicated manually on horizontal and vertical long-axis MR images. The calculated intersection points with the short-axis MR images were the basis of the automatic contour detection. Automatically derived volumes correlated highly with manually derived (short axis-based) volumes (R2 = 0.98); ejection fraction (EF) and mass showed a correlation of 0.95 and 0.93, respectively. Automatic contour detection reduced interobserver variability to 0.1 mL for endocardial end-diastolic and end-systolic volumes, 1.1 mL for epicardial end-diastolic and end-systolic volumes, 0.02% for EF, and 1.1 g for mass. Thus, the algorithm enabled highly reproducible left ventricular parameters to be obtained.

Adult↗

Improving diagnostic accuracy of MDCT coronary angiography in patients with mild heart rhythm irregularities using ECG editing.

OBJECTIVE: The objective of our study was to compare diagnostic accuracy of MDCT coronary angiography in a population of patients with mild heart rhythm irregularities before and after editing the ECG. SUBJECTS AND METHODS: Thirty-eight patients who underwent MDCT coronary angiography and conventional coronary angiography were enrolled in the study. The inclusion criterion was the presence of mild heart rhythm irregularities (i.e., premature beats; atrial fibrillation; mistriggering; or low heart rate, defined as 40 beats per minute or less) during the scan. All patients underwent MDCT with the following parameters: 16 detectors; collimation, 0.75 mm; gantry rotation time, 375 msec; 120 kV; and effective milliampere-second setting, 500-600. Images were reconstructed in two settings: before ECG editing and after ECG editing (i.e., arbitrary modification of temporal windows within the cardiac cycle at the site of mild heart rhythm irregularities). Data sets were scored for the presence of significant stenoses (> or = 50% lumen reduction) in coronary segments > or = 2 mm diameter. The results of the two groups were compared with a McNemar test, and a p value of less than 0.05 was considered significant. RESULTS: The sensitivity, specificity, and negative and positive predictive values of MDCT coronary angiography for the detection of significant stenoses before and after ECG editing were 63% (41/65) and 92% (78/85); 97% (251/260) and 96% (305/317); 87% (62/71) and 87% (81/93); 91% (251/275) and 97% (305/313), respectively (p < 0.05). The proportion of nonassessable segments was reduced from 17% (70/416) before ECG editing to 2% (10/416) after. CONCLUSION: ECG editing significantly improves diagnostic accuracy in a selected population of patients with mild heart rate irregularities.

Atrial Fibrillation↗

Optimization of CT angiography of the carotid artery with a 16-MDCT scanner: craniocaudal scan direction reduces contrast material-related perivenous artifacts.

OBJECTIVE: The objective of our study was to compare the effect of a caudocranial scan direction versus a craniocaudal scan direction on arterial enhancement and perivenous artifacts in 16-MDCT angiography of the supraaortic arteries. SUBJECTS AND METHODS: Eighty consecutive patients (51 men; mean age, 62 years; age range, 28-89 years) underwent scanning in the caudocranial direction (group 1; n = 40) or the craniocaudal direction (group 2; n = 40). All patients received 80 mL of contrast material followed by a 40-mL saline chaser bolus, both administered IV at 4 mL/sec. Bolus tracking was used. Attenuation inside the arterial lumen was measured at intervals of 1 sec throughout the data set. Attenuation in the superior vena cava (SVC) was measured. Contrast material-related perivenous artifacts were graded on a scale of 0-3 (none to extensive). RESULTS: Attenuation in the ascending aorta, carotid bifurcation, and intracranial arteries was slightly lower in group 2 versus group 1 (231 +/- 64 H, 348 +/- 52 H, and 258 +/- 48 H vs 282 +/- 43 H, 381 +/- 73 H, and 291 +/- 77 H, respectively; p < 0.05). Maximum and mean arterial attenuations were slightly lower in group 2 versus group 1 (369 +/- 58 H and 303 +/- 48 H vs 401 +/- 71 H and 334 +/- 58 H; p < 0.05). Attenuation in the SVC was much lower in group 2 versus group 1 (169 +/- 39 H vs 783 +/- 330 H; p < 0.001). Mean streak artifact score was much lower in group 2 versus group 1 (1.3 +/- 0.9 vs 2.5 +/- 0.6; p < 0.001). CONCLUSION: Use of a craniocaudal scan direction results in slightly lower attenuation of the carotid artery and much lower attenuation of the SVC. Streak artifacts are significantly reduced. This technique allows better evaluation of the ascending aorta and supraaortic arteries.

Adult↗

Higher intracoronary attenuation improves diagnostic accuracy in MDCT coronary angiography.

OBJECTIVE: The purpose of this study was to investigate whether the amount of intracoronary attenuation influences the diagnostic accuracy of MDCT coronary angiography in the detection of clinically significant stenosis. MATERIALS AND METHODS: One hundred twenty patients in sinus rhythm with suspected coronary artery disease who underwent MDCT of the heart and conventional coronary angiography were retrospectively selected. The population was divided into two groups depending on median (326 H) coronary vascular enhancement (i.e., low attenuation and high attenuation). The diagnostic accuracy of MDCT for the detection of clinically significant coronary artery lesions (> or = 50% lumen reduction) in both groups was compared with that of quantitative coronary angiography. RESULTS: The sensitivity of MDCT was 90% and 93% for the low- and high-attenuation groups, respectively. The specificity was 95% and 97%. CONCLUSION: Greater intracoronary attenuation leads to higher diagnostic accuracy in the detection of coronary artery stenosis with MDCT.

Angina Pectoris↗

Effects of primary angioplasty for acute myocardial infarction on early and late infarct size and left ventricular wall characteristics.

UNLABELLED: The effects of reperfusion on early and late infarct size and left ventricular wall characteristics were studied by performing cine-magnetic resonance imaging, first-pass perfusion, and delayed enhancement imaging in 22 patients at five days and five months after successful primary angioplasty for first acute myocardial infarction. Infarct size, end-diastolic wall thickness, and segmental wall thickening were quantified, and the extent of microvascular obstruction (MO) was evaluated qualitatively. Infarct size decreased by 31%. Segments without MO had early increased wall thickness and late partially normalized wall thickening. Segments with MO showed late wall thinning and no functional recovery at five months. OBJECTIVES: We aimed to study the effects of early successful primary angioplasty for ST-segment elevation acute myocardial infarction (AMI) on early and late infarct size and left ventricular (LV) wall characteristics. BACKGROUND: Early reperfusion treatment for AMI preserves LV function, but the effects on early and late infarct size, end-diastolic wall thickness (EDWT), and segmental wall thickening (SWT) are not well known. METHODS: In 22 patients with successful primary angioplasty for first AMI, cine-magnetic resonance imaging (MRI), first-pass perfusion, and delayed-enhancement imaging was performed at five days and five months. The extent of microvascular obstruction (MO) was evaluated on perfusion images. Infarct shrinkage was defined as the difference between the volume of delayed-enhancement at five days and five months. The EDWT and SWT were quantified on cine-MRI. RESULTS: Infarct shrinkage occurred to the same extent in small and large infarctions [r = 0.92; p < 0.001], with a mean decrease of 31% (35 +/- 21 g to 24 +/- 17 g). Dysfunctional segments without MO had an increased EDWT at five days compared with remote myocardium (9.2 +/- 1.7 mm vs. 8.4 +/- 1.7 mm; p < 0.001). At five months, EDWT in these segments became comparable to the thickness of remote myocardium (7.8 +/- 1.6 mm vs. 7.6 +/- 1.4 mm; p = 0.60), and SWT improved (21 +/- 15% to 40 +/- 24%; p < 0.001) but remained impaired (40 +/- 24% vs. 71 +/- 29%; p < 0.001). Segments with MO demonstrated wall thinning at five months (6.4 +/- 1.3 mm vs. 7.6 +/- 1.4 mm; p = 0.006) and no significant recovery in SWT (12 +/- 14% to 17 +/- 20%; p = 0.15). CONCLUSIONS: Infarct size decreased by 31%. Segments without MO had early increased wall thickness and late partial functional recovery. Segments with MO showed late wall thinning and no functional recovery at five months.

Angioplasty, Balloon, Coronary↗

Chronic pseudoaneurysm of the left ventricle.

We present a case of a 55-year-old men who suffered a silent myocardial infarction four years earlier and presented with exertional dyspnoea. Cardiac magnetic resonance imaging (CMR) and Multislice computed tomography (MSCT) was performed and revealed a giant pseudoaneursym of the lateral wall of the left ventricle with the presence of a thrombus in the lateral wall of the pseudoaneursym. We present this case since excellent non-invasive evaluation of the pseudoaneursym was feasible using state-of-the-art imaging modalities. Information on left ventricular geometry and function as well as myocardial viability and coronary anatomy is available when both MSCT and CMR are performed. This combined approach of these two imaging modalities provide clinically relevant information and may guide therapeutic decision making.

Aneurysm, False↗