PubMed Health⌕ Search

Biomedical subjects

Filiz Yalçin

Publications and source records attributed to Filiz Yalçin.

4 recordsLinked to original sources

The effect of two different polishing techniques on microleakage of new composites in Class V restorations.

AIM: The purpose of this study was to investigate the effect of polishing systems on the microleakage of a nanofill, a nanohybrid, and a microhybrid composite in Class V cavities. METHODS AND MATERIALS: Preparations were made at the cemento-enamel junction (CEJ) of 36 extracted human premolars. The teeth were randomly divided into three groups and restored with new resin composites according to the manufacturers' instructions as follows: Group 1, Filtek Supreme & Single Bond; Group 2, Grandio & Solobond; and Group 3, Artemis & Excite. The restorations were finished with diamond finishing burs. The restored/finished teeth were randomly divided into two groups and polished using the following systems: Super-Snap (Al2O2 coated, abrasive disc system, fine grit, and extra fine grit) and Astropol/Astrobrush (silicon-based abrasive polisher point and polisher brush). All specimens were thermocycled 1000 times with a 10 second dwell time. They were immersed in 0.5% aqueous basic fuchsin dye for 24 hours and then sectioned buccal-lingual-longitudinally through the center of both restorations of each tooth and evaluated under a stereomicroscope at 30X magnification. The degree of dye penetration was quantified. RESULT: No significant difference in leakage scores was observed in enamel margins (p=0.456, Kruskall Wallis test), but dentin margins were significantly affected by the different polishing systems (p=0.037, Kruskall Wallis test). The lower leakage scores were recorded for Astropol/Astrobrush polishing systems. The nanofill composite showed the least leakage among the test groups in this study. The most leakage was observed in nanohybrid composite resin (p<0.05, Mann Whitney U test). CONCLUSIONS: Under the conditions of this in vitro study: the microleakage resistance of composites at enamel margins is not significantly affected by the different polishing systems; the lowest leakage scores were recorded for Astropol/Astrobrush polishing techniques in different types of composites; and the ranking of the composite materials from most to least leakage at the dentin margins according to polishing techniques was Grandio >Artemis > Filtek Supreme.

Bicuspid↗

The effect of menopause, hormone replacement therapy (HRT), alendronate (ALN), and calcium supplements on saliva.

PURPOSE: In menopausal women many physiological changes take place, most of which are due to decreased estrogen production. It is known estrogen influences oral health in a number of ways and saliva undergoes variations depending upon the levels of this hormone. MATERIALS AND METHODS: The study was designed to evaluate the relationship of menopause, hormone replacement therapy (HRT), alendronate (ALN), and calcium supplements on salivary flow rate, saliva pH, and electrolytes. A group of a group of 14 osteoporotic women in menopause with an age average of 50.7 and 14 non-menopausal women with an age average of 42.4 and were selected as subjects. The oral status of the subjects was determined using the Community Periodontal Index of Treatment Needs (CPITN), the Decayed, Missing and Filled Teeth (DMFT) and the Decayed, Missing and Filled Surfaces (DMFS) indices. The non-stimulated whole saliva samples were subsequently collected from the women in both the control and experimental groups and then analyzed biochemically. The women comprising the experimental group received HRT supplemented with ALN and calcium; saliva collecting and analyzing procedures were repeated at the third and sixth months of the treatment. RESULTS: The most significant oral discomfort in women in the menopausal period was oral dryness, and this symptom was relieved after HRT with ALN and calcium supplements. The oral status of the non-menopausal women was better than the women in menopause. The salivary flow rate was decreased in the menopausal period and increased after HRT, ALN, and calcium supplementation. The saliva pH values were not affected by menopause and HRT with ALN and calcium supplementation. The level of Na+ was increased with menopause and did not change with HRT supplemented with ALN and calcium, whereas the K+ level decreased in the menopausal period and remained constant after HRT with ALN and calcium. The Cl- level was not affected by menopause and the HRT supplemented with ALN and calcium. The Ca++ level was not different in the two groups of women and did not change after HRT supplemented with ALN and calcium. CONCLUSION: HRT with ALN and calcium supplementation affected some factors in saliva positively.

Adult↗

The weight change of various light-cured restorative materials stored in water.

This study investigated weight changes of seven different light-cured composite restorative materials, one polyacid glass ionomer compomer, and one light-cured glass-ionomer cement following short-term and long-term storage in water. Two packable composites, three universal (hybrid) composites, one microglass composite, one polyacid glass ionomer resin composite (compomer), one microhybrid low-viscosity (flowable) composite, and one light cured glass ionomer composite cement were evaluated in this study. The weight changes of these specimens were measured daily (short-term storage), and they were measured after six weeks (long-term storage) using an electronic analytical balance. A significant difference was found in Ionoliner, Dyract AP, Opticor flow, Charisma, and Solitare 2, but no significant difference was found in the others (Filtek Z 250, Filtek P60, TPH Spectrum, and Valux Plus). Weight change showed a tendency to increase with the time of water storage. The greatest weight change occurred in light-cured glass ionomer composite cement (Ionoliner), which is followed in order by the weight changes in Dyract AP, Opticor Flow, Charisma, Solitare 2, Filtek Z250, Filtek P60, TPH Spectrum; Valux Plus had the least amount of change.

Absorption↗

Bonding to enamel and dentin using self-etching adhesive systems.

OBJECTIVES: This study investigated the effectiveness of three different dentin adhesive systems on the adhesion of resin composite to both dentin and enamel. METHOD AND MATERIALS: The flat dentin and enamel surfaces of 60 extracted human molar teeth were exposed by wet grinding with 600-grit silicon carbide paper. One total-etch self-priming adhesive system (Prime & Bond NT), one two-step self-etching primer adhesive system (Clearfil SE Bond), and one "all-in-one" self-etching adhesive system (Prompt L-Pop) were evaluated. Each bonding system was applied according to the manufacturer's instructions and followed by composite (TPH Spectrum) application. Twenty-four hours after bonding, the teeth were subjected to shear testing. There were 10 replicates for each group. RESULTS: Prompt L-Pop exhibited significantly higher bond strength values to enamel (27 +/- 4.2 MPa) than all other groups. There were no statistically significant differences for shear bond strength to dentin among adhesives. Prompt L-Pop showed the statistically significantly higher bond strength to enamel than dentin. There were no statistically significant differences between the enamel and dentin bond strengths of Clearfil SE Bond and Prime & Bond NT. CONCLUSIONS: The self-etching adhesive systems produced high bond strengths to human coronal dentin and ground enamel surfaces. These materials seem to be very promising for further clinical applications, and the results are very encouraging for the clinical success of these simplified adhesive systems. The self-etching adhesive systems produced even better bond strengths to both enamel and dentin than conventional total-etch systems, especially the "all-in-one" system, which produced the highest bond strength to enamel.

Acid Etching, Dental↗