PubMed Health⌕ Search

Biomedical subjects

Fiona Fitzpatrick

Publications and source records attributed to Fiona Fitzpatrick.

7 recordsLinked to original sources

NMR, cloud-point measurements and enzymatic depolymerization: complementary tools to investigate substituent patterns in modified celluloses.

The substituent patterns of some chemically modified celluloses were characterized as a function of their size distribution, using size-exclusion chromatography coupled to both nuclear magnetic resonance spectroscopy (NMR) and cloud-point measurements. Intact and enzymatically hydrolyzed methyl cellulose (MC) was fractionated according to size, and the level of substitution of the fractions was measured off-line using NMR. Clouding behavior was also measured as a function of size. Clear differences between hydrolyzed and nonhydrolyzed samples were observed using both techniques. For samples that had been selectively hydrolyzed using cellulose-degrading enzymes, NMR data showed a direct link between the degree of degradation and the level of substitution. Differences in the clouding behavior highlighted changes in substituent levels and substituent patterns across the size distribution. The techniques gave valuable and somewhat complementary information on the substituent distributions of the samples before and after enzymatic hydrolysis.

Bacillus↗

Molar mass distributions by gradient liquid chromatography: predicting and tailoring selectivity.

Interactive liquid chromatography (iLC) for polymer analysis is usually applied to the characterisation of distributions other than molar mass. In particular, its use for the determination of chemical-composition, functionality-type and tacticity distributions has been demonstrated. The application of iLC for the determination of molar mass distributions (MMDs), however, has not yet been fully explored. An expanded version of the reversed-phase liquid chromatography model has been developed to describe and predict how the retention behaviour of polydisperse polystyrene samples changes with molar mass. The relationship between molar mass and the parameters of the model has been investigated in some detail and non-linear correlations were found. From the model and the relationships between the model parameters and molar mass, calibration curves (retention time versus molar mass) were constructed to predict changes in chromatographic selectivity across a given molar mass range. These calibration curves were compared to experimentally obtained curves and, in most cases, excellent agreement was found. The dramatic enhancement in selectivity that can be obtained with iLC in comparison to size-exclusion chromatography (SEC) was illustrated by measuring matrix-assisted laser desorption ionisation (MALDI) MS spectra of fractions collected during a gradient-LC separation. In the low-molar mass range, essentially monodisperse fractions were obtained. Calibration curves, predicted by the model and validated experimentally using narrow-dispersity standards and MALDI-MS spectra of fractions, were used to determine the molar mass distribution of some narrowly distributed polystyrene samples. Molar mass distributions for such standards were found to be somewhat lower than the values reported by the manufacturers. The results also deviated from those obtained by MALDI-MS.

Calibration↗

New background correction method for liquid chromatography with diode array detection, infrared spectroscopic detection and Raman spectroscopic detection.

A new method to eliminate the background spectrum (EBS) during analyte elution in column liquid chromatography (LC) coupled to spectroscopic techniques is proposed. This method takes into account the shape and also intensity differences of the background eluent spectrum. This allows the EBS method to make a better estimation of the background eluent spectrum during analyte elution. This is an advantage for quantification as well as for identification of analytes. The EBS method uses a two-step procedure. First, the baseline spectra are modeled using a limited number of principal components (PCs). Subsequently, an asymmetric least squares (asLS) regression method is applied using these principal components to correct the measured spectra during elution for the background contribution. The asymmetric least squares regression needs one parameter, the asymmetry factor p. This asymmetry factor determines relative weight of positive and negative residuals. Simulations are performed to test the EBS method in well-defined situations. The effect of spectral noise on the performance and the sensitivity of the EBS method for the value of the asymmetry factorp is tested. Two applications of the EBS method are discussed. In the first application, the goal is to extract the analyte spectrum from an LC-Raman analysis. In this case, the EBS method facilitates easy identification of unknown analytes using spectral libraries. In a second application, the EBS method is used for baseline correction in LC-diode array detection (DAD) analysis of polymeric standards during a gradient elution separation. It is shown that the EBS method yields a good baseline correction, without the need to perform a blank chromatographic run.

Spectrophotometry, Infrared↗

Characterisation of fluorinated copolymers using liquid chromatography coupled on-line to mass spectrometry, with automated data interpretation.

A perfluorinated co-polyether was characterised in terms of the number and type of functional end groups present on the molecule. The polymer was separated chromatographically according to the polarity of the polymer end groups and the separation was coupled on-line to an electrospray ionisation time-of-flight mass spectrometer. Negative-mode electrospray ionisation of the relatively non-polar polymer was achieved by post-column addition of a polar constituent to the mobile phase. LC-MS analysis of polydisperse analytes is a highly data intensive technique and manual interpretation of the resulting data can be extremely complicated, especially for the characterisation of copolymers or polymers with end-group distributions. In order to overcome this problem, an automated data-analysis program was developed that allows the user to quickly determine the probability of the presence of a certain molecular compound. The program evaluated data in terms of the possible combinations of monomeric units and end groups that could be combined to make up the mass values present in the mass spectra. Using the program, the polymer can be characterised according to its molar-mass, chemical-composition and functionality-type distributions. A graphical representation of the LC-MS analyses is presented to give a clear overview of the two-dimensional separation. The identification of various end groups on the polymer is also presented graphically, as (a) a histogram (frequency of matches versus time), (b) a two-dimensional plot (masses that match the particular end group combination versus LC retention time) and (c) a plot of average chemical composition versus LC retention time.

Automation↗

Accurate prediction of the retention behaviour of polydisperse macromolecules based on a minimum number of experiments.

This study illustrates how retention models can be used to accurately predict the retention behaviour of polydisperse macromolecules in LC separations. It highlights that the number of experiments required can be drastically reduced when the relationship between the model parameters and molecular structure parameters (e.g. molar mass) can be incorporated into one global model. A practical implication of this work is that an appropriate model can then be used for the determination of molar-mass distributions for polydisperse samples. The globalised model can predict retention time as a function of molar mass and gradient slope. Both the original and globalised versions of the model were rigorously validated in terms of the difference between the predicted and experimental retention times. The original model had very low residuals and there was no apparent dependence of the errors on the applied gradient, the molar mass or the retention times. Confidence intervals for the model parameters (S and ln k0) were determined using a bootstrapping analysis of the residual errors in the predicted retention times. Confidence intervals were seen to broaden significantly as the mass of the polymer increased. The parameters were also seen to be highly correlated. For the global model, retention-time residuals remained quite low, even when the number of experiments used to determine the model parameters was reduced from approximately 100 to 10.

Chromatography, High Pressure Liquid↗

Application of the reversed-phase liquid chromatographic model to describe the retention behaviour of polydisperse macromolecules in gradient and isocratic liquid chromatography.

This paper illustrates how conventional models of chromatographic behaviour can be used to predict the separation behaviour of polydisperse macromolecules. Using polystyrene and polymethylmethacrylate homo- and co-polymeric standards, the models were validated by comparing experimental retention behaviour with that predicted by the chromatographic model. The experimental retention time of each of the samples was entered into a spreadsheet application, which calculated the parameters that best described retention (for a given model). When a correlation between the relevant parameters and molecular mass was established, that correlation was used to predict the change in retention behaviour over the molecular-mass range. An expression introduced in a previous paper, to calculate the critical mobile-phase composition of a homopolymer was validated using polystyrene homopolymers. A second expression, which can predict the elution behaviour of copolymers, was also validated. This expression can predict the retention of a copolymer, based solely onthe retention of the homopolymeric units that make up the copolymer.

Calibration↗

Predicting the behaviour of polydisperse polymers in liquid chromatography under isocratic and gradient conditions.

In this paper we describe how the existing theories to describe retention and peak width in isocratic and gradient-elution liquid chromatography can be expanded to describe the retention behaviour of natural and synthetic repetitive polymers, which feature distributions of molecules with different masses (and often different structures) rather than unambiguous molecular formulas. For polydisperse samples, it is vital that the model accommodates (isocratic) elution of sample components before the onset of a gradient, elution during the gradient, and elution after the completion of the gradient. The expanded models can readily be implemented in standard spreadsheet software, such as Excel. We have created such spreadsheets based on the conventional model for retention in reversed-phase liquid chromatography (RPLC) and on two different models for retention in normal-phase liquid chromatography. The implementation allows an easy visualization of the theoretical concept. Up to three different polymeric series can be entered, with a total of up to 100 peaks being computed and displayed in isocratic or gradient-elution chromatograms. Also visualized are "retention models" (diagrams of isocratic retention vs. composition) and "calibration curves" (retention or elution composition vs. molecular mass or degree of polymerization). The coefficients in the isocratic retention model may be correlated, as has often been observed in RPLC. It is shown that under certain conditions such a correlation corresponds to the existence of so-called critical (isocratic) conditions, at which all the members of a given polymeric series (same composition and end groups, different number of repeat units) show co-elution.

Chromatography, Liquid↗