Cementless total hip arthroplasty with the rectangular titanium Zweymuller stem. A concise follow-up, at a minimum of fifteen years, of a previous report.

Between October 1986 and November 1987, 208 total hip arthroplasties were performed with use of the cementless Zweymüller stem and a threaded cup in 200 consecutive patients. Of 102 patients (108 hips) who were available for follow-up at a minimum of 180 months postoperatively, eighty-three (eighty-nine hips) had the primary joint replacement still intact. No stem had been revised because of aseptic loosening, but we found various degrees of osteolysis around sixteen (18%) of the implants. The probability of survival of the stem at fifteen years was 0.98 (95% confidence interval, 0.96 to 1.00). The probability of survival of the cup was 0.85 (95% confidence interval, 0.79 to 0.91).

Adult↗

Cup inclination and serum concentration of cobalt and chromium after metal-on-metal total hip arthroplasty.

We investigated whether cup inclination influences serum levels of cobalt and chromium after metal-on-metal total hip arthroplasty. Out of a consecutive series, 3 groups of 20 patients each were established according to their cup inclination: greatest inclination (55 degrees -63 degrees, mean 58 degrees), intermediate inclination (44 degrees -46 degrees, mean 45 degrees), and smallest inclination (23 degrees -37 degrees, mean 33 degrees). We did not detect any statistically significant difference of serum cobalt (P = .23) or serum chromium (P = .13) levels between the 3 groups applying the Kruskal Wallis test. However, 3 patients with cup inclinations of 58 degrees , 63 degrees , and 61 degrees exhibited 9.8-53.6-fold elevated cobalt and 9.5-30.5-fold elevated chromium levels when compared with the median concentrations of this trial. We therefore recommend accurate cup placement also for metal-on-metal articulations.

Adult↗

Does the placenta inhibit the passage of chromium and cobalt after metal-on-metal total hip arthroplasty?

Umbilical cord serum and corresponding maternal serum of 3 women with uncemented metal-on-metal total hip arthroplasties were analyzed for cobalt and chromium. The women were an average 3.8 (range, 2-5) years after hip surgery. At the time of delivery, the maternal chromium concentrations were 1.6 microg/l, 0.5 microg/l, and 0.9 microg/l, respectively, and the maternal cobalt concentration was 1 microg/l in the first woman and below the detection limit in the other 2 women. Cobalt and chromium concentrations of the 3 umbilical cord sera also were below the detection limit. This indicates that-with regard to the detection limit of our laboratory-we were unable to observe a passage of cobalt and chromium ions from metal-on-metal articulations across the placenta at the time of delivery.

Arthroplasty, Replacement, Hip↗

Serum cobalt levels after metal-on-metal total hip arthroplasty.

BACKGROUND: Systemic cobalt dissemination from the Metasul Co-28Cr-6Mo-0.2C metal-on-metal total hip prosthesis has been demonstrated in the first year after implantation. The aim of this prospective study was to monitor the serum cobalt concentrations in patients during the first five years after total hip arthroplasty with a metal-on-metal articulation. METHODS: A total hip arthroplasty was performed without cement in 100 consecutive patients who had either unilateral osteoarthritis or unilateral osteonecrosis. Fifty patients were randomized to be treated with a metal-on-metal articulation, and fifty patients, with a ceramic-on-polyethylene bearing. The femoral stem was made of a Ti-6Al-7Nb alloy, and the threaded acetabular cup was made of commercially pure titanium. Blood samples were taken before the operation and at multiple time-points for five years after the operation. Serum cobalt concentrations were measured with use of atomic absorption spectrometry. RESULTS: In the metal-on-metal group, the median serum cobalt concentration was 1 micro g/L at one year after surgery and 0.7 micro g/L at five years. The median of the serum cobalt concentrations measured from three to twelve months did not differ from the median of subsequent measurements, with the numbers available. The median serum cobalt level in the control group of patients treated with the ceramic-on-polyethylene articulation was below the detection limit at all time-points. CONCLUSIONS: Systemic cobalt release from Metasul metal-on-metal articulations was demonstrated throughout the five-year study period. The median serum cobalt concentrations were found to be slightly above the detection limit and remained in a constant range. The serum cobalt concentrations did not reflect a so-called run-in wear period of the metal-on-metal articulations.

Adolescent↗

Cementless total hip arthroplasty with a tapered, rectangular titanium stem and a threaded cup: a minimum ten-year follow-up.

BACKGROUND: We report the results of cementless total hip arthroplasty with a tapered, rectangular titanium stem that was introduced in 1979 and continues to be used today with only minor changes. The aim of the design is to achieve primary stability to resist rotational and axial forces through precision rasping and press-fit implantation of a tapered, rectangular femoral component. METHODS: Between October 1986 and November 1987, 208 total hip arthroplasties with insertion of a tapered, rectangular titanium stem and a threaded cup without cement were performed in 200 consecutive patients (average age, sixty-one years; range, twenty-two to eighty-four years). RESULTS: At the time of the latest follow-up, fifty-one patients (fifty-two hips) had died and sixteen patients had been lost to follow-up, leaving 133 patients. Twelve hips had been revised, two in patients who subsequently died, leaving 123 living patients without revision. The median follow-up time was 120.7 months. Five cups needed revision surgery because of aseptic loosening; two, because of massive polyethylene wear; one, because of posttraumatic migration; and one, because of breakage. Three femoral stems were revised: one because of malpositioning (the reoperation was done five days after implantation); one, because of infection; and the third, after multiple failed acetabular revisions. The mean Harris hip score for the patients who did not have revision was 85.4 points (range, 46 to 100 points) at the time of the latest follow-up. Four patients (3%) complained of thigh pain that was not associated with another disorder. According to the criteria of Engh et al., all femoral implants were graded as stable bone-ingrown. The probability of survival of both the femoral and the acetabular component at ten years, with any revision as the end point, was 0.92 (95% confidence interval, 0.88 to 0.97). The probability of survival of the cup was 0.93 (95% confidence interval, 0.89 to 0.97), and that of the stem was 0.99 (95% confidence interval, 0.97 to 1.00). CONCLUSIONS: The results of arthroplasty with a tapered, rectangular titanium stem combined with a conical threaded cup inserted without cement were excellent at a minimum of ten years. Our data suggest that femoral stem fixation continues to be secure, while the threaded cup is prone to aseptic loosening.

Adult↗