PubMed Health⌕ Search

Biomedical subjects

Forrest C Jellison

Publications and source records attributed to Forrest C Jellison.

2 recordsLinked to original sources

A novel single step percutaneous access sheath: the initial human experience.

PURPOSE: A novel 1-step percutaneous access sheath NS has been developed that allows the insertion of a dilating balloon and renal access sheath in a single step. We present the initial human experience with this sheath. MATERIALS AND METHODS: We performed a retrospective chart and database review of the initial 30 consecutive patients undergoing percutaneous nephrostolithotomy using the NS. Data collected included patient demographics, operative and recovery parameters, and complications. RESULTS: Mean patient age was 50.4 years (range 11 to 81), mean body mass index was 31.63 kg/m(2) (range 17.1 to 65) and mean preoperative stone area was 6.23 cm(2) (range 1 to 14.6). Six and 3 patients had full and partial staghorn calculi, respectively. Access was achieved via the upper pole in 16 patients, middle pole in 7 and lower pole in 7. Mean operative time was 114.8 minutes (range 61 to 237). Mean estimated blood loss was 145.5 cc (range 10 to 500) and mean postoperative hospital stay was 4.89 days (range 2 to 14). A total of 23 patients (76.7%) had no residual calculi on postoperative computerized tomography, 5 (16.7%) had residual fragments 4 mm or less and 2 (6.7%) had residual stone fragments greater than 4 mm. There were no complications related to the NS. CONCLUSIONS: The NS is safe, easy to use and has potential advantages compared to currently available renal access sheaths.

Adolescent↗

Comparison of nonabsorbable polymer ligating and standard titanium clips with and without a vascular cuff.

PURPOSE: To compare the efficacy of nonabsorbable polymer ligating (NPL) and titanium clips applied with and without a 1-mm vascular cuff at physiologic and supraphysiologic pressures. MATERIALS AND METHODS: An in vitro equine-vessel model was created to test clip occlusion strength. Ten-millimeter NPL and standard Ti clips were applied to veins (10 mm) and arteries (10, 6, and 5 mm) with and without a 1-mm cuff and tested until they held a pressure of 300 mm Hg (veins) or 760 mm Hg (arteries) for 2 minutes or leaked. RESULTS: The NPL clip was statistically more secure on 10-mm veins with and without a cuff, 10-mm arteries with and without a cuff, and 6-mm arteries with a cuff than was the Ti clip. Leaving a 1-mm cuff resulted in a statistically higher leak point in all vessels tested except the 6-mm arteries secured with the Ti clip. CONCLUSIONS: The NPL clip was more secure than the Ti clip on larger arteries and veins. A 1-mm vascular cuff enhances the security of both NPL and Ti clips in vessels of all sizes. The NPL clip is secure and reliable in securing both arteries and veins.

Animals↗