PubMed Health⌕ Search

Biomedical subjects

François Lestremau

Publications and source records attributed to François Lestremau.

6 recordsLinked to original sources

High efficiency liquid chromatography on conventional columns and instrumentation by using temperature as a variable. Kinetic plots and experimental verification.

Theoretical aspects of temperature in liquid chromatography (LC) have mostly been studied to elucidate changes in retention behavior of small and large molecules in various solvents. That temperature also plays a significant role in chromatographic performance is less known. Kinetic plots are an established tool to predict chromatographic performance in terms of speed and efficiency that can be obtained with a certain particle size at the maximum attainable column pressure. In this paper, temperature effects on mobile phase viscosity and analyte diffusion are incorporated in these plots to prove that superior performances are within experimental reach for conventional LC columns and equipment. Verification of the modified kinetic plots with experimental data points is presented.

Chromatography, Liquid↗

Evaluation of ultra performance liquid chromatography. Part I. Possibilities and limitations.

A practical evaluation of the possibilities and limitations of ultra performance liquid chromatography (UPLC) is presented. Acquity BEH columns packed with 1.7 microm particles are evaluated by means of van Deemter and Knox plots. The columns are characterised by high optimal velocities (3.7 mm/s) and low plate heights (4.4 microm). Minimum plate heights of 2d(p) were, however, not reached and reasons are presented and discussed. Furthermore, the use of 1.7 microm particles at 1000 bar is compared, from a theoretical viewpoint, to conventional LC (3.5 and 5 microm particles at 400 bar) in terms of analysis speed and practical maximum efficiency. Experimental data are used to construct kinetic- or "Poppe-plots", which facilitate investigation of the effect of pressure and particle size on speed and efficiency. It is found that UPLC conditions hold advantages in terms of speed of analysis, for required theoretical plate counts up to approximately 80,000.

Acetophenones↗

High-efficiency liquid chromatography on conventional columns and instrumentation by using temperature as a variable I. Experiments with 25 cm x 4.6 mm I.D., 5 microm ODS columns.

High plate numbers were obtained in conventional LC by coupling columns and by using temperature to reduce the viscosity of the mobile phase. At 80 degrees C up to eight columns of 25 cm x 4.6 mm I.D. packed with 5 microm ODS particles could be coupled generating 180,000 effective plates while the pressure drop was only 350bar. For routine work, a set of four columns is preferred. The analysis times on one column operated at 30 degrees C and 1 mL/min flow rate and on four columns at 80 degrees C and 2 mL/min flow rate are the same in isoeluotropic conditions while the resolution is doubled. Multicolumn systems were successfully applied in isocratic and gradient mode for the analysis of pharmaceutical and environmental samples.

Chromatography, Liquid↗

Headspace SPME followed by GC/PFPD for the analysis of malodorous sulfur compounds in liquid industrial effluents.

Headspace SPME was used to analyse malodorous sulfur compounds in liquid industrial effluents. A pulsed flame photometric detector (PFPD) was selected for a specific and sensitive analysis. Two fibres, PDMS/Dvb and PDMS/Carboxen, which are particularly convenient for extracting small and volatile molecules were tested. To compare these fibres, both sensitivity and artefact formation were considered. The PDMS/Carboxen fibre showed the lower limits of detection and moreover the least artefact formation yields. It was therefore selected and headspace SPME extraction conditions were optimised. Limits of detection of the target compounds evaluated were 12-31 ng L(-1) and repeatability was around 7%. Due to the adsorption mechanism involved, extraction is strongly influenced by the sample matrix and the low affinity compounds can suffer displacement effects. To investigate the occurrence of this phenomenon, two sampling times corresponding to non-equilibrium (5 min) and equilibrium conditions (60 min) were investigated. An external calibration was carried out by using standard solutions for both sampling times. The developed procedure was then compared to the standard addition method on a real industrial effluent. The results obtained from the two methods and for the two extraction times were in good agreement, demonstrating that even a long sampling time can be used. Therefore, the simple and timesaving external calibration was defined as relevant for an accurate quantification of sulfur compounds by headspace SPME.

Journal Article↗

Evaluation of solid-phase microextraction for time-weighted average sampling of volatile sulfur compounds at ppb concentrations.

The potential of solid-phase microextraction (SPME) for time-weighted average (TWA) sampling of volatile sulfur compounds in air at ppb concentrations was investigated. The target compounds (hydrogen sulfide, methanethiol (MeSH), ethanethiol (EtSH), dimethyl sulfide (Me2S), and dimethyl disulfide (Me2S2)) were extracted using SPME with a Carboxen-poly(dimethylsiloxane) fiber coating, and diffusion was controlled by keeping the fiber retracted within the needle of the sampling device. The effects of several important experimental variables (air velocity, direction of air flow, analyte concentration, humidity, temperature, extraction time) were studied. The uptake by the fiber was not affected by the direction of the air flow or the air velocity. The effects of concentration, humidity, temperature, and extraction time were examined in experiments with a central composite face design. The results showed that all or most of the investigated parameters had a significant impact on the uptake rates of H2S, MeSH, EtSH, and Me2S, which invalidated time-weighted average sampling of these compounds by SPME under the tested conditions. Moreover, reverse diffusion of H2S, MeSH, and EtSH occurred at 40% relative humidity. For Me2S2, the uptake rate had a variation of only 8% within the whole experimental domain, and the experimental value derived for the uptake rate was consistent with the theoretical value. This result was confirmed by comparative analyses of industrial samples by the standard addition method. Therefore, SPME appears to be a suitable technique for TWA sampling of Me2S2 using the Carboxen-poly(dimethylsiloxane) fiber coating. Finally, in an investigation of potential losses during storage of the fiber, no significant losses of the target compounds were detected after 3 days at -80 degrees C.

Journal Article↗

Development of a quantification method for the analysis of malodorous sulphur compounds in gaseous industrial effluents by solid-phase microextraction and gas chromatography-pulsed flame photometric detection.

A quantification method for malodorous sulphur compounds in gaseous industrial effluents using solid-phase microextraction sampling followed by gas chromatography-pulsed flame photometric detection has been developed. A comparative study showed that polydimethylsiloxane-Carboxen fibre led to sufficient sensitivity to achieve the microg m(-3) human perception levels of the five analytes studied (hydrogen sulphide, methanethiol, ethanethiol, dimethyl sulphide, dimethyl disulphide). However, this coating is known to suffer from competitive adsorption, which may lead to inaccurate quantification. Therefore, external calibration can only be used under a limited range of concentrations, which were determined from Fick's diffusion law. This approach was tested on a real gaseous sample and compared with the standard addition method. Good correlations were found for ethanethiol, dimethyl sulphide and dimethyl disulphide. However, for more volatile sulphur compounds (i.e., hydrogen sulphide and methanethiol), the easy-to-use external calibration could not be applied and standard additions had to be performed for accurate quantification.

Calibration↗