Quadruple-phase MDCT of the liver in patients with suspected hepatocellular carcinoma: effect of contrast material flow rate.

OBJECTIVE: The purposes of this study were to evaluate the effect of contrast material flow rate (3 mL/sec vs 5 mL/sec) on the detection and visualization of hepatocellular carcinoma (HCC) with MDCT and the safety profile of iodixanol at different injection rates. SUBJECTS AND METHODS: In a prospective, randomized multicenter trial, 97 patients (83 men and 14 women, with a mean age of 64 years) suspected of having HCC underwent quadruple-phase (double arterial, portal venous, delayed phase) 4-16-MDCT. Patients were randomized to receive iodixanol, 320 mg I/mL (1.5 mL/kg body weight), at a flow rate of 3 mL/sec (48 patients) or 5 mL/sec (49 patients). Qualitative (lesion detection, image quality) and quantitative (liver and aortic enhancement, tumor-liver contrast) analyses and safety assessment were performed. RESULTS: Overall, 145 HCCs were detected in the 5 mL/sec group and 100 HCCs in the 3 mL/sec group (p < 0.05). More lesions equal to or less than 1 cm were detected at 5 mL/sec (33 vs 16 lesions). The late arterial phase showed significantly more lesions than the early, arterial phase (133 vs 100 and 96 vs 67 lesions, respectively, p < 0.0001). Hyperattenuating HCCs were better visualized in the late arterial phase at 5 mL/sec (excellent visualization: 54% vs 27%). Using a flow of 5 mL/sec did not increase the rate of patient discomfort or contrast media-related adverse events. Most discomfort in both groups was of mild intensity and there was no severe discomfort. CONCLUSION: For detection of HCC with MDCT, a higher flow rate of 5 mL/sec is recommended. Visualization of hyperattenuating HCC is improved with no greater discomfort or adverse events.

Carcinoma, Hepatocellular↗

Breast lesion detection and characterization at contrast-enhanced MR mammography: gadobenate dimeglumine versus gadopentetate dimeglumine.

PURPOSE: To prospectively and intraindividually compare equivalent (0.1 mmol per kilogram of body weight) doses of gadobenate dimeglumine and gadopentetate dimeglumine for accuracy of detection and characterization of breast lesions at contrast material-enhanced magnetic resonance (MR) mammography. MATERIALS AND METHODS: Ethics committee approval and informed consent were obtained. Twenty-six consecutive women (mean age, 47.8 years) suspected of having a breast tumor at mammography and sonography underwent two identical MR examinations at 1.5 T; examinations were separated by more than 48 hours but less than 72 hours. A T1-weighted three-dimensional gradient-echo sequence was used, and images were acquired before and at 0, 2, 4, 6, and 8 minutes after randomized injection of gadopentetate dimeglumine or gadobenate dimeglumine at an identical flow rate of 2 mL/sec. Separate and combined assessment of unenhanced, contrast-enhanced, and subtracted images was performed blindly by two readers in consensus. Accuracy for lesion detection was determined against a final diagnosis based on findings at conventional mammography, sonography, and surgery. Sensitivity, specificity, positive and negative predictive values, and overall accuracy for malignant lesion identification were determined against histologic results. Data were analyzed with the McNemar test, proportional odds models, and analysis of variance. RESULTS: MR mammography with gadobenate dimeglumine depicted significantly (P = .003) more lesions (45 of 46) than did that with gadopentetate dimeglumine (36 of 46), and detected lesions were significantly (P < .001) more conspicuous with gadobenate dimeglumine. Confidence for characterization was significantly (P = .031) greater with gadobenate dimeglumine. Comparison of the contrast agents for their ability to help identify malignant lesions revealed significant (P = .02) superiority for gadobenate dimeglumine: Sensitivity, specificity, positive predictive value, negative predictive value, and overall accuracy for malignant lesion identification were, respectively, 94.7%, 100%, 100%, 80.0%, and 95.6% with gadobenate dimeglumine and 76.3%, 100%, 100%, 47.1%, and 80.4% with gadopentetate dimeglumine. Quantitative evaluation of signal intensity-time curves revealed significantly (P < .001) greater lesion enhancement with gadobenate dimeglumine. CONCLUSION: Detection of breast lesions and accurate identification of malignant lesions at MR imaging are significantly superior with gadobenate dimeglumine in comparison with gadopentetate dimeglumine.

Adult↗

Low-dose multidetector-row CT angiography of the infra-renal aorta and lower extremity vessels: image quality and diagnostic accuracy in comparison with standard DSA.

To investigate the possibility of reducing X-ray exposure during multidetector-row spiral computed tomographic (MDCT) angiography and to compare the image quality and diagnostic accuracy of different dosages with digital subtraction angiography (DSA) in the evaluation of the infra-renal aorta and lower extremities vessels. Seventy-five patients, randomly divided into three groups of 25 patients each, were evaluated for atherosclerotic disease with four-row spiral CT angiography (4x2.5 mm) and DSA. MDCT scanning parameters were kept constant, except for milliamperage (mAs): group A: 50 mAs; group B: 100 mAs; group C: 130 mAs. Images were analysed by two vascular radiologists in consensus. DSA represented the standard of reference. The diagnostic value of MDCT and total radiation exposure were evaluated for each data set. The simulated effective dose was 3.7 mSv for 50 mAs, 8.2 mSv for 100 mAs and 13.7 mSv for 130 mAs for men, and 4 mSv for 50 mAs, 8.9 mSv for 100 mAs and 14.8 mSv for 130 mAs for women. The dose reduction was 74% for group A and 40% for group B. The evaluation of the presence and degree of stenoses revealed a sensitivity, specificity, accuracy, PPV and NPV of 96%, 94%, 95%, 83% and 99% for Group A (50 mAs), 96%, 96%, 96%, 89% and 99% for Group B (100 mAs) and 98%, 96%, 97%, 91% and 100% for the standard dose protocol, Group C (130 mAs). Low-dose scanning is thus a feasible and accurate option for four-row CT angiography of the peripheral vessels. This technique provides substantial reduction of the radiation dose delivered to the patient while maintaining optimal diagnostic accuracy.

Adult↗

Infrarenal aortic and lower-extremity arterial disease: diagnostic performance of multi-detector row CT angiography.

PURPOSE: To compare multi-detector row spiral computed tomographic (CT) angiography with digital subtraction angiography (DSA) in evaluation of the infrarenal aorta and lower-extremity arterial system. MATERIALS AND METHODS: Fifty patients with peripheral arterial occlusive disease were evaluated with multi-detector row CT angiography and DSA. Arteries depicted at CT angiography and DSA were graded separately for degree of stenosis as 23 anatomic segments (infrarenal aorta, right and left common iliac artery, internal iliac artery, external iliac artery, common femoral artery, superficial femoral artery, deep femoral artery, popliteal artery, anterior tibial artery, tibioperoneal trunk, posterior tibial artery, and peroneal artery). Grades included the following: 1, normal patency; 2, moderate (< or =50%) stenosis; 3, focal severe (>50%) stenosis; 4, multiple severe stenoses; and 5, occlusion. Three readers independently interpreted the images, and statistical analysis was performed. The results of image interpretation were evaluated for strength of agreement by using Cohen kappa statistics. On the basis of consensus readings, sensitivity, specificity, and accuracy for detection of stenotic lesions were calculated, with findings at DSA used as the reference standard. RESULTS: Substantial to almost perfect interobserver agreement was achieved in all cases. At DSA, 349 diseased segments were found among the 1,137 segments evaluated. Sensitivity, specificity, and accuracy, based on a consensus reading of multi-detector row CT angiograms, were 96%, 93%, and 94%, respectively. A statistically significant difference (P <.05) between DSA and multi-detector row CT angiography was present only in arteries graded 1 or 2. Interobserver agreement was almost perfect among the three readers for treatment recommendations based on findings at CT angiography and DSA. CONCLUSION: Multi-detector row CT angiography appears consistent and accurate in the assessment of patients with peripheral arterial occlusive disease.

Adult↗

Laparoscopic splenectomy: multi-detector row CT for preoperative evaluation.

PURPOSE: To prospectively evaluate multi-detector row spiral computed tomography (CT) for determination of splenic volume, splenic vascular anatomy, and presence of accessory spleens and parenchymal lesions in patients who were undergoing laparoscopic splenectomy. MATERIALS AND METHODS: Twenty-two patients who were candidates for laparoscopic splenectomy underwent multiphasic multi-detector row CT. Two observers evaluated splenic volume with two hand-tracing editing modalities. Variability between the two observers was calculated with a reliability coefficient (Cronbach alpha). A linear regression equation for each modality was generated to identify the correlation between the two observers. Multi-detector row CT angiography was evaluated for assessment of splenic vascular anatomy. Presence and number of both accessory spleens and parenchymal lesions were recorded. RESULTS: Mean splenic volume was 1,050 and 1,046 mL, respectively, for observers A and B by using each-section editing (technique 1) and 1,067 and 1,068 mL for observers A and B by using distanced editing (technique 2). For each editing modality, alpha reliability coefficient was higher than 0.99. Both techniques 1 and 2 were very highly predictive of specimen weight and had R2 values of greater than 0.99 (P <.001). CT angiograms correctly showed polar arteries in all cases and the presence of the arteria pancreatica magna in one case. Multi-detector row CT demonstrated the presence, number, and size of all accessory spleens and of focal parenchymal lesions. CONCLUSION: Multi-detector row CT volumetric and anatomic evaluation provided accurate and reproducible information.

Adult↗

Pancreatic carcinoma: the role of high-resolution multislice spiral CT in the diagnosis and assessment of resectability.

The purpose of our study was to evaluate multislice computed tomography (MSCT) in the assessment of patients with clinical, laboratory, and US suspicion of pancreatic neoplasm, and to evaluate resectability status. Forty-six patients with a suspected pancreatic tumor underwent MSCT. After a preliminary precontrast survey, a postcontrast scan was performed in the arterial and portal venous phase with the following protocol: 4 x 1-mm collimation; 1.25- and 5-mm slice thickness width, respectively, and 1- and 5-mm reconstruction interval. In all patients pathological correlation was obtained. The evaluation of all images provided a diagnosis in 44 patients, with a sensitivity, specificity, and accuracy of 97, 80, and 96%, respectively. The MSCT correctly provided a diagnosis of unresectability with sensitivity of 96%, specificity of 86%, and accuracy of 93%. Evaluation of 1-mm slices demonstrated 83 of the 91 liver metastases found at surgery; conversely, the 5-mm slices detected only 76 of these lesions. Infiltration of peripancreatic major vessels was demonstrated, and was confirmed at surgery in 18 patients. High-resolution MSCT improves prediction of resectability in patients with suspected pancreatic carcinoma. Parenchymal and vascular information can be achieved with a single MSCT examination.

Adult↗

Radial scars of the breast: contrast-enhanced magnetic resonance mammography appearance.

The purpose of this study was to evaluate the appearance of contrast-enhanced magnetic resonance mammography (CE-MRM) in patients with suspected radial scar on mammography. Thirty women with radial opacities or black star findings at mammography, preoperatively underwent CE-MRM. Examinations were performed with a 1.5 T magnet with a bilateral surface coil using a FS T2-weighted turbo spin echo (TSE) and three-dimensional (3D) dynamic T1-weighted fast low-angle shot (FLASH) sequences. Criteria for lesion evaluation included morphologic patterns and signal intensity curves. Mammography and CE-MRM findings were compared with pathologic findings. CE-MRM suggested the presence of radial scar in 18 of 30 cases and the presence of malignancy in 11 of 30 cases; 1 lesion was classified as borderline. At surgery 22 radial scars (including 4 with associated ductal carcinoma in situ) and 8 carcinomas were detected. CE-MRM provided a specificity of 89%, sensitivity of 83%, and accuracy of 87%. Differently from breast cancer, radial scars are nonenhancing at CE-MRM. Nevertheless, the possibility of nonenhancing carcinomatous foci existing within radial scars implies that surgical excision should be performed in all cases.

Aged↗

Multislice computed tomography in the preoperative assessment of adult-to-adult living donor liver transplantation: personal results.

PURPOSE: To evaluate the possible role of multislice spiral computed tomography (MSCT) as the sole imaging examination in the preoperative assessment of potential donors undergoing adult-to-adult living donor liver transplantation (LDLT). MATERIALS AND METHODS: Fifteen patients underwent MSCT with 0.5-second gantry rotation time. Pre- (4 X 2.5 mm collimation) and post-contrast (4 X 1 mm collimation) acquisitions during arterial and portal venous phases were performed after intravenous administration of 140 ml of non ionic contrast agent at 4-5 ml/s, with a delay time of 25 and 60 seconds, respectively. Pre-contrast scans with 80 and 140 kVp were acquired at the same level used to assess liver density. Real-time interaction with the post-contrast 3D data set was performed on a dedicated workstation to determine total and lobar liver volume, and to assess arterial and venous vascular anatomy. RESULTS: Steatosis was found in three patients, who as a consequence were excluded as possible candidates. MSCT correctly identified five cases of arterial anatomical variations: two cases of the right hepatic artery arising from the superior mesenteric artery, two cases of the common hepatic artery arising from the superior mesenteric artery and one case of the left hepatic artery arising from left gastric artery. In two cases portal trifurcation was considered a criterion for exclusion. A 4% error in the liver volume calculation was found at surgery, in no case considered significant. Two patients underwent surgery and three have been short-listed. CONCLUSIONS: MSCT enables complete preoperative evaluation of potential donors undergoing LDLT. Total and lobar volume determination provided accurate and reproducible information. MSCT enabled correct surgical planning without intra-operative complications. One of the limits of the technique was the poor visualization of the biliary anatomy with the need to perform an intraoperative cholangiography in all the patients.

Adult↗

Gadobenate dimeglumine (Gd-DTPA) vs gadopentetate dimeglumine (Gd-BOPTA) for contrast-enhanced magnetic resonance angiography (MRA): improvement in intravascular signal intensity and contrast to noise ratio.

PURPOSE: The purpose of this study was to compare contrast enhanced MR angiography (MRA) with gadopentetate dimeglumine (Gd-DTPA) to MRA with gadobenate dimeglumine (Gd-BOPTA), a high relaxivity paramagnetic contrast agent. MATERIALS AND METHODS: Twelve patients referred for carotid artery stenosis were examined with MR angiography using a fast spoiled gradient echo sequence. Gd-DTPA and Gd-BOPTA enhanced MR angiography were performed within 48-72 hours using a dose of 0.1 mmol/kg for Gd-BOPTA and 0.2 mmol/kg for Gd-DTPA, at a flow rate of 2 ml/s. Images were evaluated by two blinded radiologists. Qualitative and quantitative evaluations were performed comparing the sets of images from the two examinations. RESULTS: Qualitative evaluation demonstrated superior arterial contrast enhancement and vessel conspicuity with Gd-BOPTA compared with Gd-DTPA. Quantita-tive evaluation showed an improvement in both signal intensity and contrast to noise ratio with Gd-BOPTA. CONCLUSION: The greater relaxivity of Gd-BOPTA, at lower doses, compared with Gd-DTPA, provides higher intravascular signal and signal to noise ratio. Gd-BOPTA appears to be an optimal contrast agent for contrast enhanced MRA.

Carotid Stenosis↗