Publications and source records attributed to Francis A Duck.

8 recordsLinked to original sources

Medical and non-medical protection standards for ultrasound and infrasound.

Protection from inappropriate or hazardous exposure to ultrasound is controlled through international standards and national regulations. IEC standard 60601 part 1 establishes requirements for the mechanical, electrical, chemical and thermal safety for all electro-medical equipment. The associated part 2 standard for diagnostic medical ultrasonic equipment sets no upper limits on ultrasonic exposure. Instead, safety indices are defined that are intended to advise users on the degree of thermal and mechanical hazard. At present the display of these safety indices satisfies regulatory requirements in both the USA and Europe. Nevertheless there are reservations about the effectiveness of this approach to protection management. In the USA, there are national regulatory limits on diagnostic exposure, based on acoustic output from clinical equipment in use over 20 years ago. The IEC 60601 part 2 standard for therapeutic equipment sets 3 W cm(-2) as the limit on acoustic intensity. Transducer surface temperature is controlled for both diagnostic and therapy devices. For airborne ultrasound, interim guidelines on limits of human exposure published by the IRPA are now 2 decades old. A limit on sound pressure level of 100 dB for the general population is recommended. The absence of protection standards for infrasound relates to difficulties in measurement at these low frequencies.

Environmental Exposure↗

Elastography for breast cancer diagnosis using radiation force: system development and performance evaluation.

The use of impulsive acoustic radiation force for strain imaging was investigated. A focused ultrasound transducer was used to apply localized radiation force to a small volume of tissue mimic (100 mm3) for durations of 8 ms. A conventional real-time ultrasound imaging probe was used to obtain echo signals. The resulting strains were mapped using ultrasound correlation-based methods. The instantaneous strain immediately following cessation of the radiation force was observed at depth within homogeneous gels and within stiff inclusions, and was seen to vary approximately linearly with Young's modulus of the material. The highly localized and transient strain that is produced may permit the sensing of variations in tissue elastic properties that are difficult to detect with conventional elastography because of greater independence from boundary conditions. For example, the characteristic, bi-directional, high strain artefacts attributable to stress concentration, often seen with static elastography at tissue-inclusion interfaces, do not appear using the transient radiation force strain imaging technique.

Breast Neoplasms↗

Broadband measurements of the frequency dependence of attenuation coefficient and velocity in amniotic fluid, urine and human serum albumin solutions.

The frequency dependence of attenuation coefficient in amniotic fluid, urine and 4.5% and 20% human serum albumin solutions over the frequency range 5 MHz to 25 MHz was measured at both room temperature and physiological temperature using a variable path length technique. A 15 MHz (13 mm diameter) transducer was used to produce a broadband single-cycle pulse and a 4 mm diameter bilaminar polyvinylidene difluoride membrane hydrophone was used to detect the attenuated pulse. Standard time-of-flight measurement techniques were used to measure the acoustic velocity in the same fluid samples. At physiological temperature, the attenuation coefficients in amniotic fluid, urine and 4.5% and 20% human albumin solution were found to be 0.0053 f(1.65), 0.0047 f(1.67), 0.019 f(1.57) and 0.167 f(1.27) dB cm(-1), respectively, where f is in MHz. The velocities in amniotic fluid, urine and 4.5% human albumin solution at physiological temperature were found to be 1541.1 m s(-1) +/- 1.3 m s(-1), 1551.3 m s(-1) +/- 1.3 ms(-1) and 1547.3 m s(-1) +/- 1.0 m s(-1), respectively. The results provide unique data over the diagnostic and therapeutic ultrasonic frequency range that can be used as input data for theoretical models that attempt to simulate nonlinear pressure fields and temperature rises from medical ultrasonic transducers.

Amniotic Fluid↗

Broadband attenuation and nonlinear propagation in biological fluids: an experimental facility and measurements.

The design and construction of a versatile experimental facility for making measurements of the frequency-dependence of attenuation coefficient (over the range 1 MHz to 25 MHz) and nonlinear propagation in samples of biological fluids is described. The main feature of the facility is the ability to perform all of the measurements on the same sample of fluid within a short period of time and under temperature control. In particular, the facility allows the axial development of nonlinear waveform distortion to be measured with a wideband bilaminar polyvinylidene difluoride membrane hydrophone to study nonlinear propagation in biological fluids. The system uses a variable length bellows to contain the fluid, with transparent Mylar end-windows to couple the acoustic field into the fluid. Example results for the frequency-dependence of attenuation of Dow Corning 200/350 silicone fluid, used as a standard fluid, are presented and shown to be in good agreement with alternative measurements. Measurements of finite amplitude propagation in amniotic fluid, urine and 4.5% human albumin solutions at physiological temperature (37 degrees C) are presented and compared with theoretical predictions using existing models. The measurements were made using a 2.25-MHz single-element transducer coupled to a polymethyl methacrylate lens with a focal amplitude gain of 12 in water. The transducer was driven with an eight-cycle tone burst at source pressures up to 0.137 MPa. In general, given an accurate knowledge of the medium parameters and source conditions, the agreement with theoretical prediction is good for the first five harmonics.

Animals↗

Ultrasound-induced heating in a foetal skull bone phantom and its dependence on beam width and perfusion.

The cooling effect of single and multiple perfusing channels has been measured in a model of human foetal skull bone heated by wide and narrow beams of simulated pulsed spectral Doppler ultrasound (US). A focussed transducer operating with a centre frequency of 3.5 MHz, that emitted pulses of 5.7 micros duration with a repetition frequency of 8 kHz, was used. This produced a beam of power 100 +/- 2 mW with -6 dB diameters of 3.1 mm and 7.8 mm at 9 cm and 6 cm, respectively, from the transducer face. Arterial perfusion was simulated by allowing distilled water to flow in a large single channel or a grid of fine channels near the heated bone target. This study has established that: 1. perfusion-induced cooling is significantly enhanced when the bone phantom is heated by a wide rather than a narrow beam; 2. irrespective of the US beam width, a grid of small channels is more effective in cooling a heated bone target than a single larger diameter channel with the same volume flow rate; 3. the measured temperature rise and rate of temperature rise support the prediction of inverse proportionality to the US beam width; and 4. the perfusion time constants determined in our phantom model are 2 to 30 times larger than that assumed for the thermal index (TIB) algorithm.

Algorithms↗

The cooling effect of liquid flow on the focussed ultrasound-induced heating in a simulated foetal brain.

There is a need to investigate the thermal effects of diagnostic ultrasound (US) to assist the development of appropriate safety guidelines for obstetric use. The cooling effect of a single liquid flow channel was measured in a model of human foetal brain and skull bone heated by a focussed beam of simulated pulsed spectral Doppler US. Insonation conditions were 5.7 micros pulses, repeated at 8 kHz from a focussed transducer operating with a centre frequency of 3.5 MHz, producing a beam of -6 dB diameter of 3.1 mm at the focus and power outputs of up to 255 +/- 5 mW. Brain perfusion was simulated by allowing distilled water to flow at various rates in a 2 mm diameter wall-less channel in the brain soft tissue phantom material. This study established that the cooling effect of the flowing water; 1. was independent of the acoustic source power, 2. was more effective close to the flow channel, for example, there was a marked cooling at a distance of 1 mm and negligible cooling at a distance of 3 mm from the channel; and 3. initially increased at low flow rates, but further increase above normal perfusion had very little effect.

Brain↗

Nonlinear acoustics in diagnostic ultrasound.

The propagation of ultrasonic waves is nonlinear. Phenomena associated with the propagation of diagnostic ultrasound pulses cannot be predicted using linear assumptions alone. These include a progressive distortion in waveform, the generation of frequency harmonics and acoustic shocks, excess deposition of energy and acoustic saturation. These effects occur most strongly when ultrasound propagates within liquids with comparatively low acoustic attenuation, such as water, amniotic fluid or urine. Within soft tissues, similar effects occur, although they are limited by absorption and scattering. Nonlinear effects are of considerable importance during acoustic measurements, especially when these are used to predict in situ exposure. Harmonic generation may be used to create images. These offer improvements over conventional B-mode images in spatial resolution and, more significantly, in the suppression of acoustic clutter and side-lobe artifacts. B/A has promise as a parameter for tissue characterisation, but methods for imaging B/A have shown limited success.

Acoustics↗