PubMed Health⌕ Search

Biomedical subjects

Francisco Alvarez

Publications and source records attributed to Francisco Alvarez.

11 recordsLinked to original sources

Transition from Norplant to Jadelle in a clinic with extensive experience providing contraceptive implants.

OBJECTIVE: The purpose of this study was to understand the transition process from providing Norplant, the six-capsule first contraceptive implant system, to providing Jadelle, the two-rod second-generation system, in a clinical setting with extensive experience providing Norplant implants. MATERIALS AND METHODS: Two hundred forty-nine women requesting contraceptive implants from the PROFAMILIA clinic (Santo Domingo, Dominican Republic) were provided with information regarding the differences and similarities between the two implant systems being studied, including the easier insertion and removal procedures and the possible shorter use life associated with Jadelle. A questionnaire evaluating their preference and the reason why they chose either system was provided. The health care providers' opinions about the two systems were also studied. RESULTS: Fifty-three percent of the women preferred Jadelle over Norplant. The main reason behind their preference for Jadelle was its reduced number of implants with easier insertion and removal and less visibility in the arm, whereas that for Norplant was greater familiarity. Providers overwhelmingly preferred Jadelle. A 1-h presentation was sufficient training for providers experienced with Norplant. None had any problem with the management of Jadelle. CONCLUSION: The inclusion of Jadelle in a clinic with extensive experience with Norplant was easy and uneventful, but both methods should be available during a transition period of several months while confidence in the new method is being acquired by the community.

Attitude of Health Personnel↗

Evaluating the clinical safety of three vaginal applicators: a pilot study conducted in the Dominican Republic.

BACKGROUND: Targeted research on applicator safety has not been conducted as part of microbicide clinical trials and was considered necessary for ensuring safe and effective product use. Colposcopy, regarded as a standard method for assessing the safety of vaginal products, including microbicides, was used in this study to assess the external genitalia, vaginal epithelium and cervical epithelium after a single applicator use. OBJECTIVES: The objectives of this study were to assess and compare the effects of three vaginal applicators on symptoms and signs of irritation of the external genitalia, vagina and cervix as seen by colposcopy after applicator use. METHODS: Twenty women used three different vaginal applicators over three separate clinic visits 7-14 days apart and underwent a colposcopic examination before and after each applicator use. In total, the safety of each applicator was assessed over 20 product uses. RESULTS: No severe colposcopic finding was reported. Four minor colposcopic findings (petechiae) were considered possibly related to product use. No difference was found between applicators. CONCLUSIONS: This study provides reassuring data on the safety of the three applicator products from the perspective of causing vaginal trauma or irritation. Epithelial changes that could be more important for risk of disease transmission were not observed.

Administration, Intravaginal↗

Feasibility study of Nestorone-ethinylestradiol vaginal contraceptive ring for emergency contraception.

OBJECTIVE: The Nestorone/ethinylestradiol (NES/EE) vaginal ring is being developed as a regular contraceptive method by the Population Council. This ring is designed to release NES 150 microg/day and EE 15 microg/day during 1 year. Here, we report a Phase I clinical trial to determine the usefulness of this ring for emergency contraception. To that end, we tested the ability of this ring to interfere with ovulation when it is inserted during the follicular phase. METHOD: Forty-eight women protected from the risk of pregnancy by nonhormonal methods were divided into three groups, which differed by the size of the dominant follicle at the time of ring insertion: 12-14 mm (n = 16), 15-17 mm (n = 18) and >or=18 mm (n = 14) diameter. The NES/EE ring was left in the vagina for 7 consecutive days, after which it was removed. The growth of the leading follicle and plasma levels of estradiol, progesterone (P), luteinizing hormone (LH) and follicle stimulating hormone (FSH) in the ensuing 5 days after ring insertion were determined. Afterwards, steroid hormones were measured twice a week, until menses took place. All women had a control cycle before the ring cycle, and the range of maximum follicular diameter assigned to each volunteer was the same for the control and the ring cycle at the time when placebo was ingested or the ring inserted. RESULTS: During the 5-day period after ring insertion with follicles 12-17 mm, ovulation was absent in 25 of 34 cycles (p < .01 vs. control), and ovulatory dysfunction (absent, blunted or mistimed LH peak) occurred in 8 of the 9 remaining cycles (33/34 ovulatory processes altered; p < .005 vs. control). After ring insertion with follicles >or=18 mm in diameter, ovulation did not occur in 2 of 14 cycles or was dysfunctional in 7 of the 12 remaining cycles (9/14 ovulatory processes altered; p<.025 vs. control). Altogether, 87.5% of ring cycles (42/48) had either no ovulation or ovulatory dysfunction in the 5-day study period, in contrast to 39.6% (19/48 cycles) in control cycles (p < .001). Among follicles that failed to rupture within the 5-day study period, none ruptured later on in the ring-treated cycles, while 9 of 16 did so in control cycles. Sixty-two percent of ring-treated cycles were shorter than 24 days. Nausea, vaginal discharge and abdominal pain were the most frequently reported adverse events during ring use. CONCLUSION: Interference with 87.5% of ovulatory processes, without ovulation occurring later in the cycle and shortening of cycle length, suggests the NES/EE ring may be used as an emergency contraceptive method, with the potential advantage of providing continuing contraception after it has performed its emergency function.

Administration, Intravaginal↗

Contraceptive vaginal rings releasing Nestorone and ethinylestradiol: a 1-year dose-finding trial.

In a multicenter 1-year trial of contraceptive vaginal rings (rings) involving 150 women, three dose combinations of the progestin Nestorone (NES) and ethinylestradiol (EE) were compared with respect to effectiveness, safety and acceptability. Mean in vitro drug release rates for the three doses were 150 and 15, 150 and 20 and 200 and 15 microg/day of NES and EE, respectively. Each ring remained in situ for 21 days, removed for 7 days and then reinserted for a total of 13 cycles of use. We studied ring performance with respect to pregnancy and other termination events, adverse events, the extent of ovulation inhibition, serum drug levels and bleeding control. We also assessed the rings' effects on the vagina using a standardized colposcopy procedure. Seventy-two percent of the women completed the 1-year (> or = 350 days) study. In studied cycles, luteal activity (progesterone > or = 10 nmol/L) was noted in 17%, 7% and 12% of subjects with monitored cycles at the 150/15, 150/20 and 200/15 doses, respectively (p = .34). Two pregnancies occurred, both in subjects using the 200/15 microg/day ring. Breakthrough bleeding during ring use averaged about 2 days/year and breakthrough bleeding and spotting averaged about 7 days/year. In the entire trial, only two women discontinued because of bleeding problems. Medical conditions, chiefly vaginal problems, personal reasons and device loss or repeated expulsion were the principal reasons given for study discontinuation. Vaginal and cervical colposcopy, conducted with standardized techniques and standardized interpretations, revealed no elevated event incidence attributable to ring use. Clinical performance and adverse event profiles indicate that each of these 1-year NES/EE rings, used on a 21-day-in and 7-day-out regimen, provided women effective, acceptable and safe long-acting contraception under their own control.

Adult↗

Clinical performance and menstrual bleeding patterns with three dosage combinations of a Nestorone progestogen/ethinyl estradiol contraceptive vaginal ring used on a bleeding-signaled regimen.

OBJECTIVE: We examined the clinical performance of contraceptive vaginal rings (rings) delivering Nestorone (NES) progestin and ethinyl estradiol (EE). Ring removal times were signaled by menstrual events. Bleeding patterns, adverse events, patterns of use and continuation rates were the principal parameters evaluated. METHODS: In a two-stage 6-month trial, subjects were randomized to use rings releasing 50 microg/day of NES and either 10 (50/10) or 20 (50/20) microg/day of EE. Subjects were to keep rings continuously in situ until menstrual bleeding or prolonged spotting-signaled removal. Reinsertion was to occur 96 h later. After the randomized stage, an open-label 6-month trial of rings releasing 150 microg/day of NES and 15 microg/day of EE (150/15) began with the same menstrually signaled regimen. RESULTS: Two-hundred forty-six subjects participated in the trial. Six-month pregnancy rates ranged by ring dose from 1.3 to 3.9 per 100. For each ring dose combination, 6-month continuation rates were above 80 per 100. Bleeding and spotting (B+S) days in women with the 50 microg/day NES rings were similar in number to those experienced by cycling women not using contraception. Nevertheless, in the initial 90 days, fewer B+S days were reported by subjects with the 50/20 ring than by subjects with the 50/10 ring (p < .05). Throughout the trial, subjects using the 150/15 ring reported significantly fewer B+S episodes than did subjects with either 50 microg/day NES ring. CONCLUSION: Combined contraceptive rings used with a bleeding-signaled regimen led to few terminations attributed to bleeding problems and to acceptable continuation rates. The 150/15 ring appeared to induce fewer bleeding problems than did the lower-dose NES combination rings, but no important difference in 6-month continuation rates among the three doses was noted.

Adult↗

Serum Nestorone and ethinyl estradiol levels, and ovulation inhibition in women using three different dosage combinations of a Nestorone progestogen-ethinyl estradiol contraceptive vaginal ring on a bleeding-signaled regimen.

OBJECTIVES: This trial tested the hypothesis that menstrually signaled use of contraceptive vaginal rings ("rings") releasing low-dose combinations of Nestorone (NES) and ethinyl estradiol (EE) would reliably suppress luteal activity and ovulation, and prevent unintended pregnancy, while controlling the incidence of menstrual bleeding episodes and bleeding days. METHODS: Nestorone/ethinyl estradiol rings releasing 50/10, 50/20 and 150/15 mug/day were studied through 6 months. A ring was to be used continuously, until its removal was signaled by menstrual bleeding. Reinsertion was required 96 h after removal. Serum for NES, EE and progesterone were collected and assayed, and vaginal ultrasound scans were performed in three 5-week periods to examine luteal activity, follicular growth, ovulation and their correlates. In 10 subjects using the 150/15 ring, six samples were drawn in the 24-h period after ring removal to examine serum levels of NES and EE. RESULTS: One hundred sixty subjects at three doses provided blood samples. Median serum concentrations of NES and EE demonstrated dose ratios slightly below the nominal dose ratios expected. Serum NES concentrations declined 19-22% from weeks 3 to 25. Changes in EE levels depended on dose. Nestorone levels fell 81% by 24 h after ring removal and EE levels fell by 50%. Luteal activity was completely suppressed in 94-95% of cycles and in 90% of subjects. Three pregnancies occurred in subjects participating in this serum sampling study. CONCLUSION: Satisfactory serum levels of NES and EE, and a high level of ovulation suppression were achieved. Irregular ring use, however, permitted pregnancies to occur.

Contraceptive Agents, Female↗

Two-year performance of a Nestorone-releasing contraceptive implant: a three-center study of 300 women.

A 2-year trial of a single Nestorone (NES) rod implant was conducted at three Latin American centers, each enrolling 100 women. We studied the safety, effectiveness and acceptability of this progestin-releasing contraceptive implant. Three pregnancies occurred, the last at 18 months of use. Because no pregnancies were expected in the first 18 months, the trial was halted. At that time, 224 women had completed at least 18 months of use, and 99 women had used the implant for more than 24 months. Few participants used adjunctive contraception between the time the study was halted and the time they had their implant removed. No additional pregnancies occurred before the removal of the last implant. The 2-year cumulative pregnancy rate was 1.7 per 100 with a Pearl index of 0.6 per 100 for the 2-year period. The 1-year and 2-year continuation rates were 80.5 and 66.7 per 100, respectively. Menstrual and medical disturbances were the principal reasons for discontinuation, followed by planned pregnancy. Headache and weight gain frequently led to discontinuation. The NES implant had little important effect on most clinical chemistry and lipid parameters. Over the study course, the mean change in hemoglobin was <1%. Slight modification of the design of this single 2-year implant, restoring features previously examined in clinical trials, is likely to improve its effectiveness. A single NES implant appears to provide acceptable contraception for women.

Adolescent↗

A clinical trial of 7 alpha-methyl-19-nortestosterone implants for possible use as a long-acting contraceptive for men.

Several preparations of testosterone and its esters are being investigated alone or in combination with other gonadotropin-suppressing agents as possible antifertility agents for men. We studied the effectiveness of 7 alpha-methyl-19-nortestosterone (MENT) as an antispermatogenic agent in men. MENT has been shown to be more potent than testosterone and to be resistant to 5 alpha-reduction. For sustained delivery of MENT, we used a system consisting of ethylene vinyl acetate implants containing MENT acetate (Ac), administered subdermally. Thirty-five normal volunteers were recruited in 3 clinics and were randomly assigned to 1 of 3 doses: 1 (12 men), 2 (11 men), or 4 (12 men) MENT Ac implants. The initial average in vitro release rate of MENT Ac from each implant was approximately 400 micro g/day. Implants were inserted subdermally in the medial aspect of the upper arm under local anesthesia. The duration of treatment was initially designed to be 6 months. However, in 2 clinics the duration of treatment was extended to 9 months for the 2-implant group and to 12 months for the 4-implant group. Dose-related increases in serum MENT levels and decreases in testosterone, LH, and FSH levels were observed. Effects on sperm counts were also dose related. None of the subjects in the 1-implant group exhibited oligozoospermia (sperm count, <3 million/ml). Four subjects in the 2-implant group became oligozoospermic, 2 of whom reached azoospermia. Eight subjects in the 4-implant group reached azoospermia, with 1 exhibiting oligozoospermia, whereas 2 were nonresponders. Side effects generally seen with androgen administration, such as increases in erythrocyte count, hematocrit, and hemoglobin and a decrease in SHBG, were also seen in this study and were reversible. Changes in lipid parameters were moderate and transient. Liver enzymes showed small changes. This study demonstrates that MENT Ac, when administered in a sustained release fashion via subdermal implants, can inhibit spermatogenesis over a prolonged period after a single administration and has the potential to be used as a male contraceptive.

Adult↗

Cardiopulmonary exercise testing with pulmonary artery catheterization detects early pulmonary vasculature changes in patients with connective tissue diseases.

Pulmonary hypertension is a well-recognized complication of connective tissue diseases (CTD), with clinical symptoms typically limited to those with relatively advanced disease. The objective of this study was to identify patients with early pulmonary vasculature changes using cardiopulmonary exercise testing with pulmonary artery catheterization. Four patients with CTD and normal Doppler echocardiogram results identified as high risk for pulmonary hypertension on the basis of disease process underwent cardiopulmonary exercise testing with pulmonary artery catheterization. All patients had normal mean pulmonary artery pressures at rest (<25 mmHg), but exhibited an abnormal rise in mean pulmonary artery pressure with exercise. Cardiopulmonary exercise testing should be considered in patients at high risk for pulmonary hypertension to identify those individuals who may benefit from early therapeutic intervention.

Journal Article↗