PubMed Health⌕ Search

Biomedical subjects

Francisco Montero de Espinosa

Publications and source records attributed to Francisco Montero de Espinosa.

5 recordsLinked to original sources

Ultrasonic density measurement cell design and simulation of non-ideal effects.

This paper presents a theoretical analysis of a density measurement cell using an unidimensional model composed by acoustic and electroacoustic transmission lines in order to simulate non-ideal effects. The model is implemented using matrix operations, and is used to design the cell considering its geometry, materials used in sensor assembly, range of liquid sample properties and signal analysis techniques. The sensor performance in non-ideal conditions is studied, considering the thicknesses of adhesive and metallization layers, and the effect of residue of liquid sample which can impregnate on the sample chamber surfaces. These layers are taken into account in the model, and their effects are compensated to reduce the error on density measurement. The results show the contribution of residue layer thickness to density error and its behavior when two signal analysis methods are used.

Journal Article↗

Electro-acoustical characterization procedure for cMUTs.

A procedure for the electro-acoustical characterization in air of cMUTs is reported. First, the measured input electrical impedance of the transducer is used to calculate the transducer parameters at different bias voltages by fitting it with the Mason model. Then, the single membrane equivalent circuit can be calculated. Second, the cMUT impulse response is obtained through a send-and-receive experiment to be compared with the one predicted by the Mason model. In order to minimize the influence of the emitter in the obtained impulse response an ad hoc broadband piezoelectric transducer centered at the resonant frequency of the cMUT was fabricated. Using this transducer, no deconvolution of the impulse response of the emitter in the cMUT reception pulse is necessary. The procedure is tested for two cMUTs with silicon-rich nitride as structural layer and different membrane diameters (60 and 70 microm).

Electric Capacitance↗

Double frequency piezoelectric transducer design for harmonic imaging purposes in NDT.

Harmonic imaging (HI) has emerged as a very promising tool for medical imaging, although there has been little published work using this technique in ultrasonic nondestructive testing (NDT). The core of the technique, which uses nonlinear propagation effects arising in the medium due to the microstructure or the existence of defects, is the ability to design transducers capable of emitting at one frequency and receiving at twice this frequency. The transducers that have been used so far are usually double crystal configurations with coaxial geometry, and commonly using a disc surrounded by a ring. Such a geometry permits the design of broadband transducers if each transducer element is adapted to the medium with its corresponding matching layers. Nevertheless, the different geometry of the emission and reception apertures creates difficulties when resolving the images. In this work, a new transducer design with different emission and reception apertures is resented. It makes use of the traditional construction procedures used to make piezocomposite transducers and the well-known theory of the mode coupling in piezoelectric resonators when the lateral dimensions are comparable with the thickness of the piezoceramic. In this work the design, construction, and characterization of a prototype to be used in NDT of metallic materials is presented. The acoustic field is calculated using water as a propagation medium, and these theoretical predictions then are compared with the experimental measurements. The predicted acoustic performances for the case of propagation in stainless steel are shown.

Journal Article↗

3D computational method to study the focal laws of transducer arrays for NDE applications.

Based on the impulse response and the discrete representation methods, a 3D computational method has been developed to calculate the optimal focal laws to focus the ultrasonic beams through interfaces of complex geometry, and the respective transmitted ultrasonic field generated by NDE transducer arrays. 1- and 2D array transducers are considered. Two different focusing techniques are used to obtain the time delays: the first travel time on each center of the array element, and the cross correlation between the simulated signals from neighboring array elements. Applying the time delays to the array, the transmitted field can be simulated using the same computational method. Several simulations were performed to present the ability of the computational method to focus through, for instance, curved and plane surfaces between two media (acrylic-steel). A comparison between the two focusing techniques is presented.

Journal Article↗

A computational method to calculate the longitudinal wave evolution caused by interfaces between isotropic media.

This paper presents a computational method to calculate the reflected and transmitted ultrasonic fields at interfaces of complex geometry. The method is performed in two steps. As first step, the velocity potential impulse response from an arbitrary aperture is determined at the interface using the Rayleigh integral and considering the reflection and transmission coefficients. In a second step, the simulated fields are calculated by applying the Rayleigh-Sommerfeld integral to the whole, extended interface. In order to validate the method, some experimental cases as, for instance, plane and cylindrical concave surfaces between two media (water-acrylic) were tested. The experimental ultrasonic fields are in good agreement with those provided by the model. Furthermore, in the work, the compromise between the accuracy of the method and the computation time is studied.

Journal Article↗