Artifacts and pitfalls in diffusion MRI.

Although over the last 20 years diffusion MRI has become an established technique with a great impact on health care and neurosciences, like any other MRI technique it remains subject to artifacts and pitfalls. In addition to common MRI artifacts, there are specific problems that one may encounter when using MRI scanner gradient hardware for diffusion MRI, especially in terms of eddy currents and sensitivity to motion. In this article we review those artifacts and pitfalls on a qualitative basis, and introduce possible strategies that have been developed to mitigate or overcome them.

Artifacts↗

Frequency-shift based detection of BMS contrast agents using SSFP: potential for MRA.

A novel mechanism of MRI contrast enhancement, based on the detection by a balanced steady-state free precession (SSFP) sequence of the proton resonance frequency shift induced by bulk magnetic susceptibility (BMS) contrast agents, was investigated. The potential for this contrast mechanism to image blood vessels was explored. The relaxation time and the frequency shift effects of gadolinium- and dysprosium-DOTA on SSFP signal was first simulated and evaluated on a water phantom at 1.5 T. In vitro, a 5-mM concentration in contrast agent induced a 20-Hz frequency shift, leading to a signal increase of 92% for Dy-DOTA, and a 10-Hz frequency shift, leading to a signal increase of 58% for Gd-DOTA at the reference frequency, taking into account the nonlinear SSFP signal response on frequency offset. The concept was then evaluated in vivo on anesthetized rabbits. Low doses of dysprosium-DOTA were injected in their vascular system, and imaging was performed at the level of neck vessels. Following a bolus injection, mean signal changes of 31%, 20% and 14% were observed in the carotid arteries, the vertebral veins and the jugular veins, respectively. The bolus peak times in arteries and veins were consistent with the rabbit vascular circulation. This frequency-shift based contrast mechanism presents interesting potential for contrast-enhanced MR angiography (CE-MRA) compared to usual relaxation-based contrast, but further investigations on reproducibility will be necessary.

Animals↗

Evaluation of a dedicated dual phased-array surface coil using a black-blood FSE sequence for high resolution MRI of the carotid vessel wall.

PURPOSE: To investigate the ability of magnetic resonance imaging (MRI) to visualize the carotid vessel wall using a phased-array coil and a black-blood (BB) fast spin-echo (FSE) sequence. MATERIALS AND METHODS: The phased-array coil was compared with a three-inch coil. Images from volunteers were evaluated for artifacts, wall layers, and wall signal intensity. Signal intensity and homogeneity of atherosclerosis were assessed. Lumen diameter and vessel area were measured. RESULTS: Comparison between the phased-array coil and the three-inch coil showed a 100% increase in signal-to-noise ratio. BB-FSE imaging resulted in good delineation between blood and vessel wall. Most volunteers had a two-layered vessel wall with a hyperintense inner layer. MRI showed both homogeneous hyperintense and heterogeneous plaques, which consisted of a main hyperintense part with hypointense spots and/or intermediate regions. MRI lumen and area measurements were performed easily. CONCLUSION: High resolution MRI of carotid atherosclerosis is feasible with a phased-array coil and a BB-FSE sequence.

Adult↗

Interventional MR imaging at 1.5 T: quantification of sound exposure.

Sound pressure levels (SPLs) during interventional magnetic resonance (MR) imaging may create an occupational hazard for the interventional radiologist (ie, the potential risk of hearing impairment). Therefore, A-weighted and linear continuous-equivalent SPLs were measured at the entrance of a 1.5-T MR imager during cardiovascular and real-time pulse sequences. The SPLs ranged from 81.5 to 99.3 dB (A-weighted scale), and frequencies were from 1 to 3 kHz. SPLs for the interventional radiologist exceeded a safe SPL of 80 dB (A-weighted scale) for all sequences; therefore, hearing protection is recommended.

Ear Protective Devices↗