PubMed Health⌕ Search

Biomedical subjects

Franck Verschuren

Publications and source records attributed to Franck Verschuren.

13 recordsLinked to original sources

Emergency orthopaedic surgery under noninvasive ventilation after refusal for general anaesthesia.

In this observation, we report a novel use of noninvasive positive pressure ventilation in the operating room to support ventilation in an acidotic hypercapnic patient with severe acute chronic respiratory failure refuted for general anaesthesia, operated under spinal anaesthesia for a femoral fracture. The feasibility of noninvasive ventilatory assistance during surgery performed under regional anaesthesia is reported here. In selected cases, noninvasive ventilation can be used in the management of patients with acute or chronic respiratory failure requiring an urgent surgical intervention but in whom the respiratory status excluded a general anaesthesia.

Aged↗

Appropriateness of diagnostic management and outcomes of suspected pulmonary embolism.

BACKGROUND: International guidelines include several strategies for diagnosing pulmonary embolism with confidence, but little is known about how these guidelines are implemented in routine practice. OBJECTIVE: To evaluate the appropriateness of diagnostic management of suspected pulmonary embolism and the relationship between diagnostic criteria and outcome. DESIGN: Prospective cohort study with a 3-month follow-up. SETTING: 116 emergency departments in France and 1 in Belgium. PATIENTS: 1529 consecutive outpatients with suspected pulmonary embolism. MEASUREMENTS: Appropriateness of diagnostic criteria according to international guidelines; incidence of thromboembolic events during follow-up. RESULTS: Diagnostic management was inappropriate in 662 (43%) patients: 36 of 429 (8%) patients with confirmed pulmonary embolism and 626 of 1100 (57%) patients in whom pulmonary embolism was ruled out. Independent risk factors for inappropriate management were age older than 75 years (adjusted odds ratio, 2.27 [95% CI, 1.48 to 3.47]), known heart failure (odds ratio, 1.53 [CI, 1.11 to 2.12]), chronic lung disease (odds ratio, 1.39 [CI, 1.00 to 1.94]), current or recent pregnancy (odds ratio, 5.92 [CI, 1.81 to 19.30]), currently receiving anticoagulant treatment (odds ratio, 4.57 [CI, 2.51 to 8.31]), and the lack of a written diagnostic algorithm and clinical probability scoring in the emergency department (odds ratio, 2.54 [CI, 1.51 to 4.28]). Among patients who did not receive anticoagulant treatment, 44 had a thromboembolic event during follow-up: 5 of 418 (1.2%) patients who received appropriate management and 39 of 506 (7.7%) patients who received inappropriate management (absolute risk difference, 6.5 percentage points [CI, 4.0 to 9.1 percentage points]; P < 0.001). Inappropriateness was independently associated with thromboembolism occurrence (adjusted odds ratio, 4.29 [CI, 1.45 to 12.70]). LIMITATIONS: This was an observational study without evaluation of the risk for overdiagnosis. CONCLUSIONS: Diagnostic management that does not adhere to guidelines is frequent and harmful in patients with suspected pulmonary embolism. Several risk factors for inappropriateness constitute useful findings for subsequent interventions.

Belgium↗

Validation of a model to predict adverse outcomes in patients with pulmonary embolism.

AIMS: To validate a model for quantifying the prognosis of patients with pulmonary embolism (PE). The model was previously derived from 10 534 US patients. METHODS AND RESULTS: We validated the model in 367 patients prospectively diagnosed with PE at 117 European emergency departments. We used baseline data for the model's 11 prognostic variables to stratify patients into five risk classes (I-V). We compared 90-day mortality within each risk class and the area under the receiver operating characteristic curve between the validation and the original derivation samples. We also assessed the rate of recurrent venous thrombo-embolism and major bleeding within each risk class. Mortality was 0% in Risk Class I, 1.0% in Class II, 3.1% in Class III, 10.4% in Class IV, and 24.4% in Class V and did not differ between the validation and the original derivation samples. The area under the curve was larger in the validation sample (0.87 vs. 0.78, P=0.01). No patients in Classes I and II developed recurrent thrombo-embolism or major bleeding. CONCLUSION: The model accurately stratifies patients with PE into categories of increasing risk of mortality and other relevant complications. Patients in Risk Classes I and II are at low risk of adverse outcomes and are potential candidates for outpatient treatment.

Aged↗

Evaluation of biventricular ejection fraction with ECG-gated 16-slice CT: preliminary findings in acute pulmonary embolism in comparison with radionuclide ventriculography.

This study aimed to assess the feasibility of cardiac global function evaluation during a whole-chest multi-slice CT (MSCT) acquisition in patients referred for suspicion of pulmonary embolism (PE), and to compare the results with planar equilibrium radionuclide ventriculography (ERNA). Ten consecutive haemodynamically stable patients (six female, four male; mean age 69.7 years; heart rate 65-99 bpm) with suspicion of PE underwent an MSCT and ERNA within a 6 h period. CT acquisition was performed after contrast medium injection by using 16x1.5 mm collimation and retrospective ECG gating. Left ventricular (LVEF) and right ventricular (RVEF) ejection fractions were calculated using dedicated three-dimensional software. Relationships between measurements obtained with MSCT and ERNA were assessed using linear regression analysis and reliability of MSCT was assessed with intra-class correlation coefficient. Bland-Altman analysis was performed to calculate limits of agreement between MSCT and ERNA. MSCT was performed successfully in ten patients with a mean acquisition time of 16.5+/-2.8 s. Functional cardiac evaluation was possible on CT for all patients except for one due to poor opacification of right ventricle. Linear regression analysis showed a good correlation between MSCT and ERNA for the LVEF (R=0.91) and the RVEF (R=0.89) measurements. Intra-class correlation was superior for LVEF (0.92) than for the RVEF (0.68). Bland-Altman plots demonstrated that MSCT substantially overestimated the ERNA RVEF. Morphological CT data demonstrated PE in four of ten of patients and alternative diagnoses in five of ten patients. Our study reveals that MSCT with retrospective ECG gating may provide in one modality a morphological and a functional cardiopulmonary evaluation. Comparison with ERNA demonstrated a good correlation for both ventricular ejection fractions.

Aged↗

Volumetric capnography: reliability and reproducibility in spontaneously breathing patients.

Volumetric capnography provides a breath-by-breath analysis of ventilation-perfusion imbalances and deadspace volumes. The technique has been best described in intubated and ventilated patients, but promising clinical applications also concern spontaneously breathing patients. The objective of the study was to verify the reliability and reproducibility of a new capnographic program in various types of clinical conditions. In a first step, 56 patients, either healthy or with acute respiratory disorders, were connected to a sidestream gas sampler and flow sensor through a mouthpiece. An acquisition software synchronized expired CO2 and flow data to create volumetric capnographic curves. Mixed expired CO2 partial pressure, corresponding to the exhaled CO2 of the effective tidal volume, was simultaneously collected in a neoprene bag for comparison. In a second step, changes in airway deadspace before and after the adjunction of known spacer volumes were compared in six healthy volunteers. The mean difference between both methods in measuring mixed expired CO2 partial pressure was -0.9 mmHg (SE 0.2 mmHg, P<0.001). The limits of agreement extended from -4.4 to 2.5 mmHg. The interobserver correlation coefficient for reproducibility was 0.98. Airway deadspace volume, after correction for extra volumes, was not statistically different than the basic value (P=0.89). In conclusion, volumetric capnography can be compared with references when used in spontaneously breathing patients. Future developments and clinical applications should clarify its role as a non-invasive method for deadspace and ventilation-perfusion imbalances analysis.

Adult↗

Volumetric capnography as a bedside monitoring of thrombolysis in major pulmonary embolism.

OBJECTIVE: To describe the use of volumetric capnography, a plot of expired CO(2) concentration against expired volume, in monitoring fibrinolytic treatment of major pulmonary embolism. DESIGN AND SETTING: Two case reports in the emergency department of a teaching hospital. PATIENTS: Two conscious and spontaneously breathing patients (69- and 31-year-old women) with major pulmonary embolism requiring thrombolysis. Decision for thrombolysis was based on the association of right ventricular afterload on echocardiography, with respiratory failure and hypotension in the first patient, and dyspnea and hemodynamically stable parameters in the second one. INTERVENTIONS: Successive capnographic measurements were performed before, during, and after thrombolysis. Curves of volumetric capnography were obtained from a sidestream gas monitor with flow sensor and an arterial blood gas analysis for CO(2) partial pressure. MEASUREMENTS AND RESULTS: We calculated late deadspace fraction, previously suggested as the most effective capnographic parameter in the diagnosis of pulmonary embolism. Late deadspace fraction decreased in the two patients, respectively, from 64.4% to 1.1% and from 25.6% to 5.7% after thrombolysis, with a concomitant disappearance of right heart dysfunction signs on echocardiography. CONCLUSIONS: Volumetric capnography can monitor thrombolysis in major pulmonary embolism. Differences between volumetric capnography technology and the more traditional arterial to end-tidal CO(2) gradient are important to take into account for clinical application.

Adult↗

Pulmonary embolism findings on chest radiographs and multislice spiral CT.

Multislice spiral CT is becoming an increasingly important tool for diagnosing pulmonary embolism. However, in many instances, a chest radiograph is usually performed as a first-line examination. Many parenchymal, vascular, and other ancillary findings may be observed on both imaging modalities with a highly detailed depiction of abnormalities on multislice CT. A comprehensive review of chest radiograph findings is presented with side-by-side correlations of CT images reformatted mainly in the frontal plane.

Acute Disease↗

Volumetric capnography as a screening test for pulmonary embolism in the emergency department.

STUDY OBJECTIVE: To compare the diagnostic performance of volumetric capnography (VCap), which is the plot of the expired CO(2) partial pressure against the expired volume during a single breath, with the PaCO(2) to end-tidal CO(2) (EtCO(2)) gradient, in the case of suspected pulmonary embolism (PE). DESIGN: Single-center, prospective study. SETTING: Emergency department of a teaching hospital. PATIENTS: A total of 45 outpatients with positive enzyme-linked immunosorbent assay d-dimer levels of > 500 ng/mL. The diagnosis of PE was confirmed in 18 outpatients according to a validated procedure based on the ventilation-perfusion lung scan and/or spiral CT scanning. INTERVENTIONS: Curves of VCap were obtained from a compact monitor connected to a computer. A sequence of four to six stable breaths allowed the calculation of the following several variables: alveolar dead space fraction; the ratio of alveolar dead space (VDalv) to airway dead space (VDaw); the VDalv to physiologic dead space (VDphys) fraction; the slope of phase 3; and the late dead space fraction (Fdlate) corresponding to the extrapolation of the capnographic curve to a volume of 15% of the predicted total lung capacity. RESULTS: The mean (+/- SD) PaCO(2)-EtCO(2) gradient was 5.3 +/- 0.7 mm Hg in the PE-positive group and 2.8 +/- 0.7 mm Hg in the PE-negative group (p = 0.019). Four variables of the VCap exhibited a statistical difference between both groups, as follows: the VDalv/VDaw fraction(;) the slope of phase 3; the VDalv/VDphys fraction; and the Fdlate, which was 8.2 +/- 3.3% vs -7.7 +/- 2.8%, respectively (p = 0.000011). The diagnostic performance expressed as the mean area under a receiver operating characteristic curve comparison was 75.9 +/- 7.4% for the PaCO(2)-EtCO(2) gradient and 87.6 +/- 4.9% for the Fdlate (p = 0.02). CONCLUSION: Fdlate, a variable of VCap, had a statistically better diagnostic performance in suspected PE than the PaCO(2)-EtCO(2) gradient. VCap is a promising computer-assisted bedside application of pulmonary pathophysiology. Future research should define the place of this technique in the diagnostic workup of PE, especially in the presence of positive d-dimers.

Breath Tests↗

Diagnosis of acute pulmonary embolism in outpatients: comparison of thin-collimation multi-detector row spiral CT and planar ventilation-perfusion scintigraphy.

PURPOSE: To compare multi-detector row computed tomography (CT) and ventilation-perfusion (V-P) scintigraphy in the diagnosis of acute pulmonary embolism (PE) in outpatients who were cared for in the emergency department. MATERIALS AND METHODS: Ninety-four nonconsecutive patients, in whom acute PE was suspected, underwent thin-collimation multi-detector row CT (collimation, 4 x 1 mm; pitch, 1.25; scanning time, 0.5 second) and V-P scintigraphy. Concordance between CT and scintigraphic images was used in the diagnosis of PE. Pulmonary angiography was performed within 24 hours if interpretations of V-P and spiral CT images were inconclusive or discordant. Sensitivity and specificity values were calculated for V-P scintigrams and CT scans of the lungs. The rates of conclusive results for scintigraphy and CT were compared. RESULTS: The sensitivity of thin-collimation multi-detector row CT and V-P scintigraphy for the detection of PE was 96% (27 of 28; CI: 82%, 99%) and 98% (65 of 66; CI: 92%, 99%), respectively. The specificity of CT and V-P scintigraphy was 86% (24 of 28; CI: 67%, 96%) and 88% (58 of 66; CI: 77%, 94%), respectively. Seven V-P scintigrams were of intermediate probability, and one spiral CT study was indeterminate. Examinations with spiral CT yielded conclusive results more often than examinations with planar V-P scintigraphy (P <.05). Five V-P scintigrams and spiral CT scans were discordant. Twelve pulmonary angiographic examinations were performed. Angiographic findings were concordant in 10 (91%) of 11 patients with conclusive CT scans in whom pulmonary angiography was attempted. CT was used to establish an alternative diagnosis in 19 (29%) of 66 patients in whom PE was excluded. CONCLUSION: Thin-collimation multi-detector row CT is more accurate than V-P scintigraphy in the diagnosis of acute PE in outpatients. Furthermore, CT provides alternative diagnoses for patients without PE on high-quality transverse or near-isotropic reformatted images.

Acute Disease↗

Effervescent paracetamol poisoning: a case report.

Severe poisoning with effervescent paracetamol tablets has never been described in the literature. Indeed, the effervescent formulation contains high amounts of sodium and bicarbonate, both responsible for important emetic properties in the case of massive ingestion. Moreover, dissolving more than 6-8 tablets in the same glass appears to be difficult. We report a well-documented case of a patient with potentially hepatotoxic serum levels after the ingestion of 16 g effervescent paracetamol, apparently without vomiting. We show that the difficulties of a massive oral intake may be overcome by a slow intake. Nevertheless, this case report does not modify the important assertion that effervescent paracetamol use could limit the risk of life-threatening intoxication by a single massive acute overdose.

Acetaminophen↗