PubMed Health⌕ Search

Biomedical subjects

Franco Favretti

Publications and source records attributed to Franco Favretti.

12 recordsLinked to original sources

High ghrelin concentration is not a predictor of less weight loss in morbidly obese women treated with laparoscopic adjustable gastric banding.

BACKGROUND: We analyzed the role of high plasma ghrelin concentrations at surgery as a negative predictor of weight loss in morbidly obese patients treated with laparoscopic gastric banding (LAGB). METHODS: Fasting plasma ghrelin concentrations were measured in 113 women before LAGB, and 16 of them were identified as having ghrelin concentrations clearly higher than expected according to the BMI levels. The 2-year postoperative outcome of these 16 patients was compared to the outcome of the remaining subjects. RESULTS: Mean fasting plasma ghrelin concentration in the group with hyperghrelinemia was 82.3+/-23.1 pg/ml and in women with normal ghrelin was 27.1+/-11.3 pg/ml (P<0.001). No differences in age, age at onset of obesity or degree of obesity were observed between the two groups. Women with hyperghrelinemia had a weight gain during the waiting time similar to women with normal ghrelin. The prevalence of comorbidities and eating behavior disturbances was similar in the two groups, but depression was 2.5 fold more prevalent in the hyperghrelinemic women than in the women with normal ghrelin. The %EWL after LAGB surgery was similar in women with high and normal ghrelin concentrations, with no differences in levels of postoperative band filling. No differences in band-related complications or revisional surgery rate were observed between the two groups. CONCLUSION: A high fasting ghrelin concentration at baseline did not significantly affect the outcome after LAGB in morbidly obese women, in terms of weight loss and complications rate.

Adult↗

Weight loss and postoperative complications in morbidly obese patients with binge eating disorder treated by laparoscopic adjustable gastric banding.

BACKGROUND: The authors investigated the outcome of morbidly obese patients with binge eating disorder (BED) treated surgically with laparoscopic adjustable gastric banding. METHODS: The 5-year outcomes of 130 patients with BED and 249 patients without BED are described. The diagnosis of BED was made preoperatively and all patients with BED were supported with psychological therapy. RESULTS: Patients with and without BED had similar BMI levels before surgery. More patients with than without BED had depressive symptoms and associated minor disturbances of eating behavior (night eating and grazing). Percent excess weight loss (%EWL) in the first 5 years after surgery was similar in patients with and without BED. The percentage of BED patients showing %EWL >50% at the 5-year evaluation was 23.1, and 25.7% in non-BED patients. The percentage of patients showing weight regain in the last 4 years of follow-up was similar in binge eaters (20.8%) and in non-binge eaters (22.5%). The 5-year frequency of gastric pouch and esophageal dilatation was significantly higher in binge eaters than in non-binge eaters (25.4 vs 17.7 %, P<0.05 and 10.0 vs 4.8%, P<0.05, respectively). Binge eaters underwent a higher number of postoperative band adjustments than non-binge eaters (3.0+/-2.1 vs 2.6+/-1.9, P<0.05) and the maximum band fill after surgery was higher in the BED patients than in non-BED patients (3.2+/-1.2 vs 2.8+/-1.3 ml, P<0.01). CONCLUSION: Morbidly obese patients with BED supported by adequate psychological treatment can have good outcomes after gastric banding.

Adaptation, Psychological↗

Progress in implantable gastric stimulation: summary of results of the European multi-center study.

BACKGROUND: The Implantable Gastric Stimulator (IGS(R)), a pacemaker-like device, has been found to be safe and effective to induce and maintain weight loss. The LOSS (Laparoscopic Obesity Stimulation Survey) is a prospective non-randomized trial which enrolled 69 patients involving 11 investigator centers in 5 European Countries. In 19 patients, ghrelin was analyzed. METHODS: Between January 2002 and December 2003, 69 patients (F/M 49/20), mean age 41 years (18-65) underwent IGS implantation. Mean BMI was 41 (35-57), mean weight 115.0 kg (65-160) and mean excess weight (EW) 52 kg (13-89). The IGS was actived 30 days after implantation. In a subset of 19 patients studied further, 0, 6, and 12 months appetite and satiety score were evaluated and 0 and 6 months ghrelin profile was analyzed. RESULTS: The mean +/- standard error %EWL was: 8.6+/-1.8 at 1 month, 15.8+/-2.3 at 3 months, 17.8+/-2.6 at 6 months, 21.0+/-3.5 at 10 months, and 21.0+/-5.0 at 15 months. There were no intraoperative surgical or long-term complications. 7 intra-operative gastric penetrations occurred, observed by gastroscopy, without sequelae. 1 patient required a reoperation to remove a retained lead needle. In the subset of 19 patients, appetite was reduced and post-prandial and inter-prandial satiety was increased after IGS implantation. In the 19 patients, despite weight reduction, ghrelin did not increase. CONCLUSION: IGS can be implanted laparoscopically with minimal perioperative complications. Appetite is reduced and satiety is increased after the implantation. Ghrelin levels could be one of the mechanisms explaining weight loss and weight maintenance in IGS patients. If weight loss is maintained, IGS could be considered a good option for selected patients.

Adolescent↗

Short-term effects of weight loss on the cardiovascular risk factors in morbidly obese patients.

OBJECTIVE: To analyze the short-term effects of weight loss on the cardiovascular risk factors in morbidly obese patients. RESEARCH METHODS AND PROCEDURES: Five metabolic cardiovascular risk factors (blood glucose, blood pressure, total cholesterol, high-density lipoprotein (HDL)-cholesterol, and triglycerides) were determined before and 15.3 +/- 2.1 months after laparoscopic gastric banding in 650 morbidly obese patients. Global cardiovascular risk was calculated according to the Prospective Cardiovascular Münster (PROCAM) scoring system. RESULTS: Mean weight loss was 22.7 +/- 20.4 kg. Normalization of the metabolic alteration was observed in 67.3% of patients with diabetes, 38.3% of patients with hypercholesterolemia, 72.5% of patients with low HDL-cholesterol, 72.3% of patients with hypertriglyceridemia, and 46.7% of patients with hypertension. PROCAM score fell from 31.4 +/- 11.6 to 28.0 +/- 12.0 points (p < 0.001). The modifications of total cholesterol and blood pressure were unrelated to percentage weight loss. Percentage weight loss was significantly related to the reductions of fasting blood glucose, triglyceride level, and the PROCAM score and to the increase of HDL-cholesterol concentrations observed after surgery. However, the strength of these four relationships was generally low. The variations of HDL-cholesterol concentrations and blood pressure levels were more influenced by actual energy balance than by the extent of weight loss. DISCUSSION: Weight loss observed in the first 12 to 18 months after gastric banding was associated with a significant improvement of single cardiovascular risk factors and global risk. On the other hand, the extent of weight loss was poorly related to the magnitude of improvement in cardiovascular risk.

Adult↗

Treatment of morbid obesity with the Transcend Implantable Gastric Stimulator (IGS): a prospective survey.

BACKGROUND: The implantable gastric stimulator (IGS), a pacemaker-like device, has been found to be safe and effective to induce and maintain weight loss. We present our experience with 20 morbidly obese patients. METHODS: Between September 20 and November 22, 2002, 20 patients (F/M 12/8), mean age 40.3 years (23-62) underwent IGS implantation. Mean BMI was 40.9 (33.9-48.2), mean weight 115.0 kg (87.0-137.0) and mean excess weight (EW) 51.3 kg (35.6-70.1).Co-morbitidies were: 3 cases of hypertension, 1 diabetes, 1 dislipidemia and 1 depression. Mean operative time was 58.5 min (37-85). The IGS was actived 30 days after implantation. Patients were advised to follow a low calorie diet and behavior modification (to avoid fat and to ingest more liquids during meals, to chew slowly, to eat vegetables before main meals, and to perform exercise daily). RESULTS: Mean +/- standard error percent excess weight loss (%EWL) was: 10.6+/-1.8 at 1 month; 15.0+/-2.3 at 2 months; 16.6+/-2.6 at 3 months; 18.1+/-3.5 at 4 months; 15.5+/-3.5 at 6 months; 18.9+/-3.5 at 8 months; and 23.8+/-5.0 at 10 months. There were no intra-operative surgical or long-term complications. There were 3 intra-operative gastric penetrations, observed by gastroscopy, without sequelae. One patient with hypertension ceased his medical therapy at the 4th month. CONCLUSION: IGS can be implanted laparoscopically with minimal perioperative complications. The observed weight loss is comparable to other noninvasive procedures. If weight loss is maintained, IGS could be considered as a first choice therapy in the treatment of morbid obesity in selected patients.

Adult↗

Preoperative weight loss by intragastric balloon in super-obese patients treated with laparoscopic gastric banding: a case-control study.

BACKGROUND: The authors investigated the usefulness of preoperative treatment with the BIB intragastric balloon in super-obese patients before undergoing laparoscopic adjustable gastric banding (LAGB). METHODS: The case-control study involved 43 case patients treated with the intragastric balloon followed by LAGB ("Case" group) and 43 sex-, age- and BMI-matched historical controls treated with LAGB alone. RESULTS: Mean length of the intragastric balloon treatment was 164.4+/-39.7 days, with a fill volume of 609+/-95 ml. Total complication rate with balloon was 7.0% and percent excess weight loss (%EWL) was 26.1 +/- SD 9.3 %. At the time of gastric band placement, both operative time and hospital stay were shorter in patients treated previously with the balloon (Case group) than in the Control group patients. No Case patients required conversion to open surgery or had intraoperative complications. In the Control group, the rate of conversion was 16.3% (P<0.05) and the rate of intraoperative complications was 7.0%. Postoperative follow-up length was 1.1+/-1.0 years in Case patients and 4.4+/-1.8 years in Control patients (P<0.001). The %EWL produced by the intragastric balloon in the Case patients was identical to the %EWL observed in the first 6 months after LAGB in the Control group (26.1+/-9.3 vs 25.3+/-12.4%). %EWL 6 months after banding was higher in the Case patients than in Controls (33.6+/-12.5 vs 25.3+/-12.4%, P<0.01). However, no significant difference in %EWL between the two groups was observed at the subsequent postoperative evaluations. CONCLUSION: Preoperative treatment with the intragastric balloon reduced the risk of conversion to open surgery and the risk of intraoperative complications in super-obese patients treated with LAGB. Preoperative treatment with the intragastric balloon did not change the total weight loss after LAGB.

Adult↗

Postoperative management of laparoscopic gastric banding.

BACKGROUND: The authors investigated the postoperative management of morbidly obese patients treated by laparoscopic adjustable gastric banding (LAGB) with the Lap-Band System. METHODS: The 3-year postoperative band management is presented in 379 morbidly obese patients, divided according to intra-operative band filling and quartiles of maximum postoperative band filling. RESULTS: LAGB resulted in a 40.8 +/- 24.5 percent excess weight loss (%EWL). Stoma stenosis occurred in 87 patients (23.0%), pouch dilatation in 52 (13.7%) and esophageal dilatation in 22 (5.8%). Most band-related complications were controlled by simple band deflation. The mean number of postoperative band adjustments was 2.3 +/- 1.7, and mean maximum band filling after surgery was 2.8 +/- 1.2 ml. Weight loss at 3 years was identical in 205 patients who had the band completely unfilled at surgery and in 174 patients who had the band filled with 1 to 3 ml of sterile saline. The rate of band-related complications was significantly lower in the first group. No differences in %EWL were observed between quartiles of maximum band filling after surgery. The rate of band-related complications increased with increasing levels of postoperative maximum band filling. In patients with the band filled with < 3.0 ml of sterile saline at 6 months, the inflation of further saline produced a dose-related increase in the rate of weight loss. In patients with the band filled with > 3.0 ml of sterile saline at 6 months, the inflation of further saline was associated with a reduced %EWL. CONCLUSION: Postoperative adjustability of the Lap-Band was useful in the treatment of band-related complications and was able to significantly influence the rate of weight loss. On the other hand, aggressive postoperative band filling was associated with an increased rate of complications.

Adult↗

Avoiding postoperative complications with the LAP-BAND system.

The most frequently occurring complications associated with the LAP-BAND (INAMED Health, Santa Barbara, CA) include gastric prolapse, stoma obstruction, esophageal and gastric pouch dilatation, erosion, and access port problems. This article describes the causes of these complications and details some points for their prevention and treatment. As techniques for placement of the LAP-BAND have evolved, complication rates have declined. For example, occurrence of gastric prolapse was reduced from the initially reported rates of 22% to less than 5%. The emergence of many problems, such as gastric pouch dilatation or prolapse, can be minimized with proper operative technique and close postoperative management and follow-up. As with other major surgical procedures, particularly those performed in the bariatric population, complications associated with the LAP-BAND system are unavoidable but are rarely life-threatening if managed appropriately. Surgeons and patients should adopt strategies that will help avoid complications and be sensitive to any indication of their emergence.

Dilatation↗

Patient management after LAP-BAND placement.

Severe obesity is a chronic disease requiring continuing care. Optimal outcomes of laparoscopic adjustable gastric banding using the LAP-BAND (INAMED Health, Santa Barbara, CA) depend on accurate placement of the band and excellent postplacement care, which requires a long-term commitment from both the patient and the bariatric surgical team. Adjustability is a key feature of the LAP-BAND system, and knowing when and how much to adjust requires careful judgment. Two methods of approaching the art of adjustment are described: the office adjustment and the radiologic adjustment. A properly placed and adjusted band produces prolonged satiety after a small meal, facilitating a major reduction in dietary intake leading to weight loss. Healthy food choices, increased activity and exercise, and the behavioral changes necessary to achieve these are essential elements of all weight loss programs. The LAP-BAND program is no exception. Follow-up requires monitoring of the comorbidities of obesity and metabolic and nutritional status. Communication and collaboration with the patient's primary care provider are important. All of the elements above are necessary to provide the comprehensive care that contributes to optimal patient outcomes.

Diet↗

Liver volume and visceral obesity in women with hepatic steatosis undergoing gastric banding.

OBJECTIVE: To investigate the relationships between visceral obesity and hepatic steatosis in obese patients undergoing adjustable silicone gastric banding with the LAP-BAND. RESEARCH METHODS AND PROCEDURES: Six premenopausal, morbidly obese women with an ultrasonographic diagnosis of liver steatosis were evaluated before surgery and 8 and 24 weeks after surgery. Liver volume and body fat distribution were simultaneously analyzed by total-body multislices magnetic resonance imaging. RESULTS: Before surgery, the only variable found to be correlated with liver volume was visceral adipose tissue volume (r = 0.91; p < 0.01). Weight loss was 9.9 +/- 3.8 kg in the period from 0 to 8 weeks (p < 0.01) and 7.1 +/- 4.9 kg in the the period from 8 to 24 weeks (p < 0.05). Total fat showed a statistically significant reduction of 6.2 +/- 4.0 liters in the 0- to 8-week period and a further significant reduction of 7.7 +/- 3.9 liters in the 8- to 24-week period. Visceral adipose tissue showed a statistically significant reduction of 1.0 +/- 0.9 liters in the 0- to 8-week period (p < 0.05) but only a further, not significant reduction of 0.6 +/- 0.7 liters in the 8- to 24-week period. The relative reduction of visceral fat in the 0-to 8-week period was higher than the relative reduction of total fat. Liver volume also showed a statistically significant reduction of 0.24 +/- 0.26 liters in the first phase of weight loss (p < 0.05), corresponding to a relative reduction of 12.3 +/- 10.6%. During the 8- to 24-week period, liver volume was substantially stable. DISCUSSION: Hepatomegaly was associated with visceral obesity in morbidly obese women with liver steatosis. In the phase of rapid weight loss after gastric surgery, a preferential mobilization of visceral fat, compared with total adipose tissue, occurred. This preferential visceral fat loss was associated with a significant reduction in liver volume.

Alanine Transaminase↗

Outcome predictors in morbidly obese recipients of an adjustable gastric band.

BACKGROUND: The authors investigated the outcome predictors in obese patients who underwent laparoscopic adjustable banding with the Lap-Band. METHODS: The 3-year excess weight loss (EWL) and rate of band-related complications (pouch dilatation and port leakage) were analyzed in 260 morbidly obese patients, according to several possible predictive characteristics. Success rate (EWL > 50%), failure rate (EWL < 20%) and weight regain rate (regain of > 10% EWL between 1 and 3 yrs) were considered. RESULTS: The Lap-Band produced a 43.0 +/- 22.3% EWL, corresponding to a BMI reduction from 46.6 +/- 7.0 to 36.8 +/- 6.6 kg/m2. Success rate was 35.7%, failure rate was 14.1% and weight regain rate was 20.7%. Pouch dilatation occurred in 32 patients (12.3%), band erosion in 2 (0.8%), port leakage in 74 (28.5%), and port twisting in 2 (0.8%). Major band-related surgery was requested in 11 patients (4.2%) and minor port-related surgery in 62 patients (23.9%). Significant success predictors were found to be age < 40 years and BMI < 50 kg/m2. Significant failure predictors were found to be male sex and non-sweet eating behavior. Significant weight regain predictors were found to be BMI < 50 kg/m2 and the occurrence of a port leakage. Port leakage was significantly more frequent in women and in patients with BMI < 50 kg/m2. The prevalence of pouch dilatation was threefold higher in women than in men. CONCLUSIONS: Lap-Band was associated with a good outcome and with a low rate of severe complications. The outcome was more influenced by physiological and technical reasons than by psychological or behavioural factors.

Adult↗

An adjustable silicone gastric band for laparoscopic treatment of morbid obesity--technique and results.

The laparoscopic application of an adjustable silicone gastric band (Lap-Band System, Bioenterics, Carpinteria, CA) (Fig. 1), based on a similar device introduced by Kuzmak in 1986, is gaining widespread acceptance as a gastric restrictive procedure in treatment of morbid obesity. The advantage of an operation that does not open the gastrointestinal tract and can be performed laparoscopically is obvious. This procedure, using the laparoscopic approach , has been performed in our institutions since 1992. The goals of this article are to describe both our standardized surgical technique that minimized the morbidity rate and its results.

Adolescent↗