PubMed Health⌕ Search

Biomedical subjects

Frandics P Chan

Publications and source records attributed to Frandics P Chan.

13 recordsLinked to original sources

Effects of exercise and respiration on hemodynamic efficiency in CFD simulations of the total cavopulmonary connection.

Congenital heart defects with a single functional ventricle, such as hypoplastic left heart syndrome and tricuspid atresia, require a staged surgical approach to separate the systemic and pulmonary circulations. Ultimately, the venous or pulmonary side of the heart is bypassed by directly connecting the vena cava to the pulmonary arteries with a modified t-shaped junction. The Fontan procedure (total cavopulmonary connection, TCPC) completes this process of separation. To date, computational fluid dynamics (CFD) simulations in this low pressure, passive flow, intrathoracic system have neglected the presumed important effects of respiration on physiology and higher "stress" states such as with exercise have never been considered. We hypothesize that incorporating effects of respiration and exercise would provide more realistic estimates of TCPC performance. Time-dependent, 3D blood flow simulations are performed by a custom finite element solver for two patient-specific Fontan models with a novel respiration model, developed to generate physiologic time-varying flow conditions. Blood flow features, pressure, and energy efficiency are analyzed at rest and with increasing flow rates to simulate exercise conditions. The simulations produce realistic pressure and flow data, comparable to that measured by catheterization and echocardiography, and demonstrate substantial increases in energy dissipation (i.e. decreased performance) with exercise and respiration due to increasing intensity of small scale vortices in the flow. As would be expected, these changes are highly dependent on patient-specific anatomy and Fontan geometry. We propose that respiration and exercise should be incorporated into TCPC CFD simulations to provide increasingly realistic evaluations of TCPC performance.

Blood Flow Velocity↗

Primary interpretation of thoracic MDCT images using coronal reformations.

OBJECTIVE: The objective of this study was to evaluate the accuracy and efficiency of primary interpretation of thoracic MDCT using coronal reformations as compared with transverse images. SUBJECTS AND METHODS: Fifty patients (18 females, 32 males; age range, 15-93 years; mean age, 63.6 years) underwent 4-MDCT of the chest (detector width, 1 mm; beam pitch, 1.5). Contrast material was administered in 20 of the 50 patients. Coronal and transverse sections were reformatted into 5-mm-thick sections at 3.5-mm intervals. All available image and clinical data consensually reviewed by two thoracic radiologists served as the reference standard. Subsequently, three other thoracic radiologists independently evaluated reformatted coronal and transverse images at two separate review sessions. Each image set was assessed in 58 categories for abnormalities of the lungs, mediastinum, pleura, chest wall, diaphragm, abdomen, and skeleton. Interpretation times and number of images assessed were recorded. Sensitivity, specificity, and interobserver concordance were calculated. Differences in mean sensitivities and specificities were evaluated with Wilcoxon's signed rank test. RESULTS: The most common findings identified were pulmonary nodules (n = 73, transverse images; n = 72, coronal images) and emphysema (n = 45, transverse; n = 40, coronal). The mean detection sensitivity of all lesions was significantly (p = 0.001) lower on coronal (44% +/- 26% [SD]) than on transverse (51% +/- 22%) images, whereas the mean detection specificity was significantly (p = 0.005) higher (96% +/- 5% vs 95% +/- 6%, respectively). Reporting findings for significantly (p < 0.001) fewer coronal images (mean, 63.0 +/- 4.6 images) than transverse images (mean, 91.9 +/- 8.8 images) took significantly (p = 0.025) longer (mean, 263 +/- 56 sec vs 238 +/- 45 sec, respectively). CONCLUSION: Primary interpretation of thoracic MDCT is less sensitive and more time-consuming using 5-mm-thick coronal reformations as compared with transverse images.

Adolescent↗

MDCT angiography of pediatric vascular diseases of the abdomen, pelvis, and extremities.

Multi-detector-row computed tomography (MDCT) enables rapid, noninvasive, high-resolution, and three-dimensional imaging of pediatric vascular diseases. In this paper, we explore the adaptation of the MDCT angiographic principles to pediatric patients for vascular diseases of the abdomen, pelvis, and extremities. Special emphasis is placed on the practical aspects of how to perform these studies. Optimizations of scan parameters, contrast medium usage, radiation dose, and three-dimensional image processing are discussed in detail. We provide practical guidance on how to choose between MR angiography and CT angiography. Finally, we review important pediatric vascular diseases, categorized into traumatic injuries, inherited vascular diseases, congenital vascular diseases, vasculitides, and surgical planning and assessment. In each category, we discuss how CT angiography can be tailored to maximize its clinical benefits.

Adolescent↗

Steady-state free precession MR imaging: improved myocardial tag persistence and signal-to-noise ratio for analysis of myocardial motion.

Tagging with balanced steady-state free-precession (SSFP) magnetic resonance (MR) imaging by using a steady-state storage scheme for myocardial motion analysis was evaluated. Signal-to-noise ratio (SNR), blood-tissue contrast, and tag persistence in volunteers and phantoms showed improved performance of SSFP imaging with tagging compared with that of radiofrequency spoiled gradient-echo (SPGR) MR imaging with tagging. Choice of flip angle with SSFP imaging involved a trade-off among SNR, blood-tissue contrast, and tag persistence. Increased SNR and tag persistence can be achieved simultaneously with SSFP imaging compared with SPGR tagging methods. As a result, the proposed technique may be useful for analysis of diastolic ventricular function.

Adult↗

Composite spirometric-computed tomography outcome measure in early cystic fibrosis lung disease.

With the advent of therapies aimed at young patients with cystic fibrosis, who have mildly reduced pulmonary function, the need for improved outcome measures that discriminate treatment effects has become important. Pulmonary function measurements or chest high-resolution computed tomography (HRCT) scores have been separately used to assess interventions. We evaluated these modalities separately and together during a treatment study to develop a more sensitive outcome measure. In a 1-year trial, 25 children randomized either to daily Pulmozyme or to normal saline aerosol were evaluated at randomization and at 3 and 12 months. Outcome variables were pulmonary function test (PFT) results, a global HRCT score, and a composite score incorporating PFTs and HRCT scoring. Regression analyses with generalized estimating equations permitted estimation of the difference in treatment effect between groups over time for each outcome. The largest difference in treatment effects observed at 12 months, measured by the percentage change from baseline, were with the composite total and maximal CT/PFT scores (35.4 and 30.4%), compared with mean forced expiratory flow during the middle half of the FVC (FEF25-75%) (13.0%) and total and maximal global HRCT scores (6.2%, 7.2%). The composite total and maximal CT/PFT scores were the most sensitive outcome measures for discriminating a treatment effect in children with cystic fibrosis with normal or mildly reduced pulmonary function during a 1-year trial of Pulmozyme.

Adolescent↗

Time-resolved three-dimensional phase-contrast MRI.

PURPOSE: To demonstrate the feasibility of a four-dimensional phase contrast (PC) technique that permits spatial and temporal coverage of an entire three-dimensional volume, to quantitatively validate its accuracy against an established time resolved two-dimensional PC technique to explore advantages of the approach with regard to the four-dimensional nature of the data. MATERIALS AND METHODS: Time-resolved, three-dimensional anatomical images were generated simultaneously with registered three-directional velocity vector fields. Improvements compared to prior methods include retrospectively gated and respiratory compensated image acquisition, interleaved flow encoding with freely selectable velocity encoding (venc) along each spatial direction, and flexible trade-off between temporal resolution and total acquisition time. RESULTS: The implementation was validated against established two-dimensional PC techniques using a well-defined phantom, and successfully applied in volunteer and patient examinations. Human studies were performed after contrast administration in order to compensate for loss of in-flow enhancement in the four-dimensional approach. CONCLUSION: Advantages of the four-dimensional approach include the complete spatial and temporal coverage of the cardiovascular region of interest and the ability to obtain high spatial resolution in all three dimensions with higher signal-to-noise ratio compared to two-dimensional methods at the same resolution. In addition, the four-dimensional nature of the data offers a variety of image processing options, such as magnitude and velocity multi-planar reformation, three-directional vector field plots, and velocity profiles mapped onto selected planes of interest.

Contrast Media↗

In vivo validation of numerical prediction of blood flow in arterial bypass grafts.

In planning operations for patients with cardiovascular disease, vascular surgeons rely on their training, past experiences with patients with similar conditions, and diagnostic imaging data. However, variability in patient anatomy and physiology makes it difficult to quantitatively predict the surgical outcome for a specific patient a priori. We have developed a simulation-based medical planning system that utilizes three-dimensional finite-element analysis methods and patient-specific anatomic and physiologic information to predict changes in blood flow resulting from surgical bypass procedures. In order to apply these computational methods, they must be validated against direct experimental measurements. In this study, we compared in vivo flow measurements obtained using magnetic resonance imaging techniques to calculated flow values predicted using our analysis methods in thoraco-thoraco aortic bypass procedures in eight pigs. Predicted average flow rates and flow rate waveforms were compared for two locations. The predicted and measured waveforms had similar shapes and amplitudes, while flow distribution predictions were within 10.6% of the experimental data. The average absolute difference in the bypass-to-inlet blood flow ratio was 5.4 +/- 2.8%. For the aorta-to-inlet blood flow ratio, the average absolute difference was 6.0 +/- 3.3%.

Anastomosis, Surgical↗

Can a multiphasic contrast-enhanced three-dimensional fast spoiled gradient-recalled echo sequence be sufficient for liver MR imaging?

OBJECTIVE: The purpose of this study was to determine the accuracy of a multiphasic gadolinium-enhanced three-dimensional (3D) fast spoiled gradient-recalled echo sequence alone in the detection and characterization of focal liver lesions compared with a comprehensive liver evaluation using multiphasic gadolinium-enhanced 3D fast spoiled gradient-recalled echo, T1-weighted, and fat-suppressed fast spin-echo T2-weighted sequences. MATERIALS AND METHODS: A retrospective review of abdominal MR imaging examinations in 61 patients was performed. All MR examinations included unenhanced spin-echo T1-weighted, unenhanced fat-suppressed fast spin-echo T2-weighted, and multiphasic gadolinium-enhanced 3D fast spoiled gradient-recalled echo sequences obtained during successive breath-holds. The liver was evaluated for focal lesions first with the 3D spoiled gradient-recalled echo sequences and then, during a separate sitting, with the T1- and T2-weighted sequences. The usefulness of each sequence in the detection and characterization of lesions was recorded. The gold standard for lesion detection and characterization was all three imaging sequences reviewed together. RESULTS: A total of 114 focal liver lesions were identified, 54 of which were simple cysts. The 3D spoiled gradient-recalled echo sequence alone detected 92 (81%) of the 114 lesions, and the T1- and T2-weighted sequences detected 95 (83%) of the 114 lesions. Of the 60 lesions that were not simple cysts, the 3D spoiled gradient-recalled echo sequence alone detected 58 (97%), and T1- and T2-weighted sequences detected 51 (85%). In 24% of the patients with lesions, the T1- and T2-weighted sequences were found to be helpful for the characterization of lesions. CONCLUSION: A multiphasic contrast-enhanced 3D fast spoiled gradient-recalled echo sequence alone detects most of the clinically relevant focal liver lesions. Additional liver examination using both unenhanced T1- and T2-weighted sequences is helpful for lesion characterization but increases the detection rate only minimally.

Aged↗

Time-resolved 3-dimensional velocity mapping in the thoracic aorta: visualization of 3-directional blood flow patterns in healthy volunteers and patients.

OBJECTIVE: An analysis of thoracic aortic blood flow in normal subjects and patients with aortic pathologic findings is presented. Various visualization tools were used to analyze blood flow patterns within a single 3-component velocity volumetric acquisition of the entire thoracic aorta METHODS: Time-resolved, 3-dimensional phase-contrast magnetic resonance imaging (3D CINE PC MRI) was employed to obtain complete spatial and temporal coverage of the entire thoracic aorta combined with spatially registered 3-directional pulsatile blood flow velocities. Three-dimensional visualization tools, including time-resolved velocity vector fields reformatted to arbitrary 2-dimensional cut planes, 3D streamlines, and time-resolved 3D particle traces, were applied in a study with 10 normal volunteers. Results from 4 patient examinations with similar scan prescriptions to those of the volunteer scans are presented to illustrate flow features associated with common pathologic findings in the thoracic aorta. RESULTS: Previously reported blood flow patterns in the thoracic aorta, including right-handed helical outflow, late systolic retrograde flow, and accelerated passage through the aortic valve plane, were visualized in all volunteers. The effects of thoracic aortic disease on spatial and temporal blood flow patterns are illustrated in clinical cases, including ascending aortic aneurysms, aortic regurgitation, and aortic dissection. CONCLUSION: Time-resolved 3D velocity mapping was successfully applied in a study of 10 healthy volunteers and 4 patients with documented aortic pathologic findings and has proven to be a reliable tool for analysis and visualization of normal characteristic as well as pathologic flow features within the entire thoracic aorta.

Adult↗

Computed tomography angiography: state-of-the-art imaging using multidetector-row technology.

Multidetector-row computed tomography (MDCT) is an essential diagnostic modality for many clinical algorithms. This is particularly true with regard to the evaluation of cardiovascular disease. As a result of increased image acquisition speed, improved spatial resolution, and greater scan volume, MDCT angiography (computed tomography angiography [CTA]) has become an excellent noninvasive imaging technique, replacing intra-arterial digital subtraction angiography for most vascular territories. The clinical success of CTA depends on precise synchronization of image acquisition with optimal vascular enhancement. As technology continuously evolves, however, this task can be challenging. It remains important to have a fundamental knowledge of the principles behind technical parameters and contrast medium administration. This article reviews these essential principles, followed by an overview of current clinical applications.

Angiography↗