Establishment of detailed reference values for luteinizing hormone, follicle stimulating hormone, estradiol, and progesterone during different phases of the menstrual cycle on the Abbott ARCHITECT analyzer.

During a normal menstrual cycle, serum levels of luteinizing hormone (LH), follicle-stimulating hormone (FSH), estradiol, and progesterone can vary widely between cycles for the same woman, as well as between different woman. Reliable reference values based on the local population are important for correct interpretation of laboratory results. The purpose of our study was to determine detailed reference values for these hormones throughout the menstrual cycle using the Abbott ARCHITECT system. From 20 volunteers (age 20-36 years) with normal cycles and no use of oral contraceptives, samples were taken every day during their cycle. Volunteers received three vaginal ultrasound examinations (days 10 and 13, and 1 or 2 days after ovulation) to measure follicular and corpus luteum development. Hormone levels were measured using the corresponding ARCHITECT assay and were synchronized to the LH peak. Median, and 5th and 95th percentile values were determined for each day of the cycle, as well as for early follicular (days -15 to -6), late follicular (days -5 to -1), LH peak (day 0), early luteal (+1 to +4), mid-luteal (days +5 to +9), and late luteal (days +10 to +14) phases of the cycle. Based on our data, we were able to establish detailed reference values for LH, FSH, estradiol, and progesterone, which should aid in the interpretation of results for these reproductive hormones in a variety of circumstances.

Adult↗

Prevalence of abnormal thyroid stimulating hormone and thyroid peroxidase antibody-positive results in a population of pregnant women in the Samara region of the Russian Federation.

Undiagnosed thyroid disease is a common problem with significant public health implications. This is especially true during pregnancy, when the health of both the mother and the developing child can be adversely affected by abnormal maternal thyroid function. Measurement of serum thyroid stimulating hormone (TSH) and thyroid peroxidase antibodies (TPO-Ab) are two common ways to assess maternal thyroid status. The objective of our study was to determine the prevalence of abnormal TSH and TPO-Ab tests in a population of pregnant women in the Samara region of the Russian Federation. Serum samples were obtained from 1588 pregnant women as part of their routine antenatal care. TSH and TPO-Ab were measured, and trimester-specific reference values for TSH (2.5-97.5 percentiles) were calculated using TPO-Ab-negative women. TSH results outside these ranges were considered abnormal; TPO-Ab levels outside the manufacturer's reference range (>12 IU/mL) were considered abnormal. Overall, the prevalence of abnormal results was 6.3% for TSH and 10.7% for TPO-Ab. High TSH (>97.5 trimester-specific percentile) and TPO-Ab-positive results were most common in the first trimester (5.7% and 13.8%, respectively). TSH levels were associated with gestational age and TPO-Ab status, and with maternal age in TPO-Ab-negative women. TPO-Ab status was associated with both maternal and gestational age. Women with TSH >2.5 mIU/L had a significantly increased risk of being TPO-Ab-positive, and this risk increased with age. Based on our data, we conclude that abnormal TSH and TPO-Ab are common in pregnant women of the Samara region. Given the association of thyroid dysfunction to adverse pregnancy outcomes, screening of this population for abnormal thyroid function should be considered.

Adolescent↗

A comparison of different sample matrices for evaluating functional sensitivity, imprecision and dilution linearity of the Abbott ARCHITECT i2000 TSH assay.

Important performance characteristics for any thyroid-stimulating hormone (TSH) assay include low-end sensitivity, precision across a wide dynamic range, and linear specimen dilution. Laboratories often characterize the performance of their TSH assay using many different sample matrices (e.g. native human serum, synthetic buffer, processed human serum, etc.). However, this can lead to possible confusion as the relationships between sample matrix and assay performance are often poorly understood. The purpose of our study was to evaluate the performance of the ARCHITECT i2000 TSH assay using a variety of different sample matrices. Functional sensitivity was found to be essentially equivalent in both hyperthyroid patient sera (0.0035 microIU/ml) and TSH affinity-stripped (0.0038 microIU/ml) sample matrices. Assay imprecision was also independent of sample matrix, with total imprecision < or = 5.3% for both synthetic buffer and serum matrices. Similarly, specimens were found to dilute linearly over a wide range in both serum and synthetic buffer matrices. We conclude that the i2000 TSH assay measures TSH similarly in a variety of sample matrices. This is an important design feature for this immunoassay which provides assurance that analytical performance assessed with matrices other than unprocessed human serum are representative of assay performance seen with patient specimens.

Calibration↗