Implantation strategy of the atrial dipole impacts atrial sensing performance of single lead VDD pacemakers.

Intermittent atrial undersensing is observed in a considerable percentage of patients with single lead VDD pacemakers. Analyzing the 2-year data of the Saphir Multicenter Follow-Up Study, the authors investigated predictors for the occurrence of undersensing. The study included 194 patients with high degree AV block who received a VDD pacemaker system with an identical sensing amplifier. Placement strategy of the atrial dipole was left to the discretion of the implanting physician. At the final position, atrial potential amplitudes were measured during deep and shallow respiration. Atrial dipole position was determined by intraoperativefluoroscopy subdividing the right atrium in a high, mid, and low portion. Undersensing was defined by evidence of at least one not sensed P wave during Holter monitoring or exercise testing and by the presence of 0.1-0.2 mV amplitudes in the P wave amplitude histogram of the pacemaker. Incidence of undersensing was 25.8%; 9.3% of patients showed frequent (> 5%) or symptomatic undersensing. Patients with undersensing were older (76.6 +/- 10.6 vs 64.2 +/- 14.8 years), showed a lower minimum of intraoperative atrial potential amplitude (P(min) 0.86 +/- 0.64 vs 1.43 +/- 0.77 mV), a wider range of potential amplitude (deltaP 1.71 +/- 1.44 vs 0.94 +/- 0.84 mV), and a higher incidence of dipole placement in the low right atrium (50.0% vs 11.1 %, P < 0.001 for all comparisons). In a multivariate regression analysis, patient age > 66 years, Pmin < 0.6 mV, > 1.3 mV and atrial dipol placement in the lowright atrium were independently predictive for undersensing. Minimal atrialpotential amplitude, range of potential amplitude, and atrial dipole position influence atrial sensing performance in single lead VDD pacing. Thus, implantation guidelines should reflect these rules to improve the outcome of VDD pacemaker recipients.

Adult↗

Continuous Holter telemetry of atrial electrograms and marker annotations using a common Holter recording system: impact on Holter electrocardiogram interpretation in patients with dual chamber pacemakers.

The impact of continuous telemetry of atrial electrogram and marker annotations on Holter ECG interpretation was assessed in 98 patients with bipolar dual chamber pacemakers (VDD pacemakers n = 29, DDD(R) systems n = 69). Atrial electrogram and marker annotations were continuously sampled by a telemetry coil that was externally positioned on the pacemaker pocket, amplified, and transduced to a three-channel Holter ECG recorder in addition to an ECG recording. Holter tapes were analyzed by two experienced investigators for quality of P wave recognition and episodes suspicious of pacemaker dysfunction. Initially, only the ECG channel was analyzed. Thereafter, results were compared to those achieved on the basis of the complete recording including atrial electrogram and marker annotations. Recognition of atrial rhythm was markedly improved by Holter telemetry. During 99.3% of recording time telemetry showed a satisfying quality, whereas ECG alone allowed a reliable P wave recognition only during 84.4% of recording time (P < 0.001). One hundred twenty-nine episodes suspicious of pacemaker malfunction occurred in 17 of 98 patients. By analysis of ECG, only 78.3% of episodes were concordantly classified by the investigators. However, 98.4% of all episodes were properly identified when atrial electrogram and marker annotations were added to the analysis (P < 0.001). In particular, discrimination between atrial undersensing, sinus bradycardia, and atrial sensed events within the refractory periods was facilitated. Holter telemetry of atrial electrogram and marker annotations facilitates the analysis of Holter ECGs in pacemaker recipients and improves the detection of pacemaker dysfunctions.

Aged↗

Mechano-electrical feedback underlying arrhythmias: the atrial fibrillation case.

Mechanoelectrical feedback (MEF) has become firmly established as a mechanism in which mechanical forces experienced by myocardial tissue or cell membranes convey alterations in electrophysiologic characteristics of such tissue. Observations to date mainly concern mechanically induced changes in action potential duration, resting and active potential amplitude, enhanced pacemaker frequency, or afterdepolarizations. While some of these changes (i.e. after depolarizations) may give rise to premature beats, a role of MEF in explaining sustained ventricular tachyarrhythmias has so far been elusive. Here, we review recent findings showing that acute atrial dilatation facilitates atrial fibrillation (AF) and that two stretch-activated channel (SAC) blockers (gadolinium and GsMTx-4) are able to suppress stretch-facilitated AF. These findings strongly support a role of MEF and SACs in promoting sustained arrhythmias and point to a new class of antiarrhythmic drugs.

Animals↗