Behavior of CAL72 osteoblast-like cells cultured on zirconia ceramics with different surface topographies.

OBJECTIVES: Because of its inherent strength, biocompatibility, and tooth-like color, zirconia ceramics have the potential to become an alternative to titanium as dental implant material. This study aimed at investigating the osteoblastic response to yttrium-stabilized tetragonal zirconia polycrystal (Y-TZP) with different surface topographies. METHODS: CAL72 osteoblast-like cells were cultured on machined (TZP-m), airborne particle abraded (TZP-s), and airborne particle abraded and acid-etched Y-TZP (TZP-sa) surfaces. Polystyrene and airborne particle abraded with large grit and acid-etched (SLA) titanium served as a reference control. The surface topography was examined by scanning electron microscopy (SEM) and profilometry. At culture days 3, 6, and 12, cell proliferation, at day 12 cell morphology, and cell-covered surface area were determined. RESULTS: The surface roughness of Y-TZP was increased by airborne particle abrasion and additionally by acid etching. No statistically significant differences were found between average roughness (R(a)) and maximum peak-to-valley height (R(p-v)) values of airborne particle abraded and acid-etched Y-TZP and SLA titanium. Whereas the cell proliferation assay revealed statistically significant greater values at day 3 for surface-treated Y-TZP and polystyrene cultures as compared with machined Y-TZP, no differences between the Y-TZP groups, SLA titanium, and polystyrene were observed at culture days 6 and 12. CONCLUSIONS: Cell morphology and cell-covered surface area were not affected by the type of substrate. The results suggest that roughened Y-TZP is an appropriate substrate for the proliferation and spreading of osteoblastic cells.

Acid Etching, Dental↗

Glycosaminoglycan degradation reduces mineralized tissue-titanium interfacial strength.

Although the localization of the proteoglycan/glycosaminoglycan (GAG) complex at the bone-titanium implant interface has been implied, the role of proteoglycans on the establishment of bone-titanium integration is unknown. The hypothesis to be tested was that proteoglycans play an important role in establishing bone-titanium interfacial adhesion. The objective of this study is to investigate the effect of proteoglycan knockdown by GAG enzymatic degradation on the interfacial strength between mineralized tissue and titanium having different surface topographies. Rat bone marrow-derived osteoblastic cells were cultured on either a machined titanium disk or an acid-etched titanium disk. At day 21 of culture, one of the three following GAG degradation enzymes was added into the culture; chondroitinase AC, chondroitinase B, or keratanase. After 3 days of incubation (at day 24 of culture), the laser spallation technique was applied to the samples in order to assess the tissue-titanium interfacial strength. In this technique, a laser-generated stress wave is used to separate the tissue-titanium interface, and the interfacial strength is determined interferometrically by recording the transient free surface velocity of the tissue. Mineralized tissue cultured on the acid-etched titanium showed 20-30% higher tissue interfacial strength than that cultured on the machined titanium (p < 0.0001). For both the machined and acid-etched surface cultures, administration of the enzyme reduced the interfacial strength by 25-30% compared with the untreated control cultures (p < 0.0001). There were no differences in the effect among the three different enzymes tested. A nanoindentation study revealed that the enzyme treatment did not affect the elastic modulus of the mineralized tissue. Scanning electron microscopic and energy dispersive spectroscopic analyses revealed less post-spallation tissue remnant on the titanium substrates when treated with the enzymes. The tissue remnant was greater in amount on the acid-etched surface than on the machined surface. The results suggest that there exists not only mechanical interlocking but also biological interfacial adhesion between the mineralized tissue and titanium, in which the proteoglycan/GAG complex is involved.

Animals↗

Enhanced mineralized tissue adhesion to titanium over polystyrene assessed by the nano-scratch test.

The critical load determined by the scratch test is regarded to be a representative measure of coating adhesion in the field of engineering. This study aimed to evaluate the method for its usefulness for assessing the mineralized tissue-titanium interface strength. Osteoblastic cells derived from rat bone marrow were cultured on polystyrene, titanium-coated polystyrene, and titanium disks with either a machined or dual-acid etched surface. Nano-scratch testing was performed on mineralized tissue specimens at culture day 28. The scratch path was monitored by light microscopy until complete delamination of mineralized tissue from the substrate occurred, and the required force was recorded as the critical load. Energy-dispersive spectroscopic analysis was used to verify the delamination. The mean critical load values (+/- standard deviations) were as follows: polystyrene 31 mN (+/-1), titanium-coated polystyrene 67 mN (+/-4), machined titanium 76 mN (+/-4), DAE titanium 107 mN (+/-3), with statistical differences (P < 0.05; ANOVA). No elemental calcium and phosphorous were observed in the delaminated areas. The nano-scratch test applied to cultured mineralized tissue differentiated the critical load from various culture conditions: polystyrene vs. titanium; titanium with different surface topographies. Culturing mineralized tissue on titanium, especially on roughened surfaces, increased the tissue critical load. The nano-scratch test may be useful to evaluate mineralized tissue adhesion properties in titanium cultures.

Animals↗

Osteoblasts generate harder, stiffer, and more delamination-resistant mineralized tissue on titanium than on polystyrene, associated with distinct tissue micro- and ultrastructure.

UNLABELLED: This study revealed that osteoblasts generate harder, stiffer, and more delamination-resistant mineralized tissue on titanium than on the tissue culture polystyrene, associated with modulated gene expression, uniform mineralization, well-crystallized interfacial calcium-phosphate layer, and intensive collagen deposition. Knowledge of this titanium-induced alteration of osteogenic potential leading to enhanced intrinsic biomechanical properties of mineralized tissue provides novel opportunities and implications for understanding and improving bone-titanium integration and engineering physiomechanically tolerant bone. INTRODUCTION: Bone-titanium integration is a biological phenomenon characterized by continuous generation and preservation of peri-implant bone and serves as endosseous anchors against endogenous and exogenous loading, of which mechanisms are poorly understood. This study determines the intrinsic biomechanical properties and interfacial strength of cultured mineralized tissue on titanium and characterizes the tissue structure as possible contributing factors in biomechanical modulation. MATERIALS AND METHODS: Rat bone marrow-derived osteoblastic cells were cultured either on a tissue culture-grade polystyrene dish or titanium-coated polystyrene dish having comparable surface topography. Nano-indentation and nano-scratch tests were undertaken on mineralized tissues cultured for 28 days to evaluate its hardness, elastic modulus, and critical load (force required to delaminate tissue). Gene expression was analyzed using RT-PCR. The tissue structural properties were examined by scanning electron microscopy (SEM), collagen colorimetry and localization with Sirius red stain, mineral quantification, and localization with von Kossa stain and transmission electron microscopy (TEM). RESULTS: Hardness and elastic modulus of mineralized tissue on titanium were three and two times greater, respectively, than those on the polystyrene. Three times greater force was required to delaminate the tissue on titanium than that on the polystyrene. SEM of the polystyrene culture displayed a porous structure consisting of fibrous and globular components, whereas the titanium tissue culture appeared to be uniformly solid. Cell proliferation was remarkably reduced on titanium. Microscopic observations revealed that the mineralized tissue on titanium was composed of uniform collagen-supported mineralization from the titanium interface to the outer surface, with intensive collagen deposition at tissue-titanium interface. In contrast, tissue on the polystyrene was characterized by collagen-deficient mineralization at the polystyrene interface and calcium-free collagenous matrix formation in the outer tissue area. Such characteristic microstructure of titanium-associated tissue was corresponded with upregulated gene expression of collagen I and III, osteopontin, and osteocalcin mRNA. Cross-sectional TEM revealed the apposition of a high-contrast and well-crystallized calcium phosphate layer at the titanium interface but not at the polystyrene interface. CONCLUSIONS: Culturing osteoblasts on titanium, compared with polystyrene, enhances the hardness, elastic modulus, and interfacial strength of mineralized tissue to a higher degree. Titanium per se possesses an ability to alter cellular phenotypes and tissue micro- and ultrastructure that result in enhanced intrinsic biomechanical properties of mineralized tissue.

Animals↗

Fracture strength after dynamic loading of endodontically treated teeth restored with different post-and-core systems.

STATEMENT OF PROBLEM: Prefabricated metal and ceramic posts can be used with direct or indirect cores as an alternative to the conventional cast post and core. It is unclear how the fracture strength of zirconia posts with composite or ceramic cores and titanium posts with composite cores compares to the fracture strength of gold posts and cores after dynamic loading. PURPOSE: This study compared the fracture strength of endodontically treated, crowned maxillary incisors with limited ferrule length and different post-and-core systems after fatigue loading. MATERIAL AND METHODS: Sixty-four caries-free, human maxillary central incisors were divided into 4 groups. After root canal treatment, Group 1 was restored with titanium posts and composite cores, Group 2 with zirconia posts and composite cores, and Group 3 with zirconia posts and heat-pressed ceramic cores. Teeth restored with cast-on gold posts and cores served as the controls (Group 4). Teeth were prepared with a circumferential shoulder including a 1 to 2 mm ferrule; all posts were cemented with an adhesive resin cement, restored with complete-coverage crowns, and exposed to 1.2 million load cycles (30 N) in a computer-controlled chewing simulator. Simultaneous thermocycling between 5 degrees C and 55 degrees C was applied for 60 seconds with an intermediate pause of 12 seconds. All specimens that did not fracture during dynamic loading were loaded until fracture in a universal testing machine at a crosshead speed of 1.5 mm/min; loads were applied at an angle of 130 degrees at the incisal edge. Fracture loads (N) and modes (repairable or catastrophic) were recorded. The Kruskal-Wallis test was used to compare fracture loads among the 4 test groups. Analyses were conducted both with and without the specimens that failed during the chewing simulation. A Fisher exact test was performed to detect group differences in fracture modes. A significance level of P<.05 was used for all comparisons. RESULTS: The following survival rates were recorded after the chewing simulation: 93.8% (Group 1), 93.8% (Group 2), 100% (Group 3), and 87.5% (Group 4). The median fracture strengths for Groups 1 to 4 were 450 N, 503 N, 521 N, and 408 N, respectively. No significant differences were detected among the groups. The use of zirconia posts resulted in a nonsignificant lower number of catastrophic root fractures. CONCLUSION: Within the limitations of this study, the results suggest that zirconia posts with ceramic cores can be recommended as an alternative to cast posts and cores. If a chairside procedure is preferred, zirconia or titanium posts with composite cores can be used. Clinical trials are required to verify these in vitro results.

Ceramics↗

Three-dimensional bone-implant integration profiling using micro-computed tomography.

PURPOSE: The capability of micro-computed tomography (microCT) for quantitative analysis of peri-implant bone has not been previously addressed. This study aimed to establish and validate a method to use this technique for 3-dimensional bone-implant integration profiling. MATERIALS AND METHODS: Unthreaded cylindric implants with a dual acid-etched surface were placed into the right femurs of 7 Sprague-Dawley rats. Two weeks postimplantation, the femurs were harvested and measured with a desktop micro-tomographic scanner with an isotropic resolution of 8 microm. To validate the microCT outcome, ground histologic sections and corresponding CT slices were compared with respect to bone morphometry. RESULTS: Bone-implant integration profiles assessed by microCT revealed that the percentage of cancellous bone gradually increased with proximity to the implant surface, while the percentage of cortical bone was not affected by proximity to the implant. Using the optimized segmentation threshold, the bone configuration in the microCT images corresponded to that observed in the histologic sections. The correlation between microCT and histology was significant for cortical (r = 0.65; P < .05) and cancellous bone (r = 0.92; P < .05) at distances of 24 to 240 microm from the implant surface, but no significant correlation was found for the area from 0 to 24 microm from the surface. DISCUSSION AND CONCLUSION: The results support the usefulness of microCT assessment as a rapid, nondestructive method for 3-dimensional bone ratio measurements around implants, which may provide new perspectives for osseointegration research. Further study is necessary, however, to address the inherent metallic halation artifact, which potentially confounds peri-implant bone assessment.

Animals↗