PubMed Health⌕ Search

Biomedical subjects

Frank Dieterle

Publications and source records attributed to Frank Dieterle.

10 recordsLinked to original sources

Probabilistic quotient normalization as robust method to account for dilution of complex biological mixtures. Application in 1H NMR metabonomics.

For the analysis of the spectra of complex biofluids, preprocessing methods play a crucial role in rendering the subsequent data analyses more robust and accurate. Normalization is a preprocessing method, which accounts for different dilutions of samples by scaling the spectra to the same virtual overall concentration. In the field of 1H NMR metabonomics integral normalization, which scales spectra to the same total integral, is the de facto standard. In this work, it is shown that integral normalization is a suboptimal method for normalizing spectra from metabonomic studies. Especially strong metabonomic changes, evident as massive amounts of single metabolites in samples, significantly hamper the integral normalization resulting in incorrectly scaled spectra. The probabilistic quotient normalization is introduced in this work. This method is based on the calculation of a most probable dilution factor by looking at the distribution of the quotients of the amplitudes of a test spectrum by those of a reference spectrum. Simulated spectra, spectra of urine samples from a metabonomic study with cyclosporin-A as the active compound, and spectra of more than 4000 samples of control animals demonstrate that the probabilistic quotient normalization is by far more robust and more accurate than the widespread integral normalization and vector length normalization.

Nuclear Magnetic Resonance, Biomolecular↗

Metabolite projection analysis for fast identification of metabolites in metabonomics. Application in an amiodarone study.

The assignment of significantly changed NMR signals, which were identified with the help of multivariate models, to individual metabolites in biofluids is a manual and tedious task requiring knowledge in chemometrics and NMR spectroscopy. Metabolite projection analysis, introduced in this work, allows automatic linking of multivariate models with metabolites by skipping the level of manual NMR signal identification. The method depends on the projection of sets of metabolite NMR spectra from a database into PCA or PLS models of NMR spectra of biofluid samples. Metabolites that are significantly changed can be identified graphically in metabolite projection plots or numerically as projected virtual concentration. The method is demonstrated together with a newly introduced algorithm for refined nonequidistant binning using a metabonomics study with amiodarone as administered drug. Amiodarone can induce phospholipidosis in the lung and liver, which is accompanied by associated organ toxicity in these organs. It is shown how metabolite projection analysis allows easy and fast tentative assignment of all structures of metabolites whose concentrations in the urine samples significantly changed upon dosage. These metabolites had also been identified previously by manually interpreting the multivariate models and spectra. Among these metabolites, phenylacetylglycine was also identified as being significantly increased. This metabolite has recently been proposed as urinary biomarker for phospholipidosis.

Amiodarone↗

Application of metabonomics in a compound ranking study in early drug development revealing drug-induced excretion of choline into urine.

Selecting drug candidates based on toxicity is an important step in early drug development. In this case study, it is shown how metabonomics is applied to a ranking study, in which drug candidates with equal pharmacological activities are selected based on least toxic side effects. The metabonomic analyses were carried out on an animal study that followed an established protocol for pilot toxicology/ranking studies in rats, however, not specifically modified for a metabonomic assessment. It is shown how conditions not specificially adopted for metabonomics investigations can significantly influence the metabolic profiles recorded by NMR. Furthermore, it is shown how the multivariate analysis of the NMR spectra identified an extreme excretion of an endogenous metabolite into urine induced by two out of the five drug candidates. The subsequent structure elucidation by two-dimensional NMR experiments and a subsequent validation by spiking experiments identified the metabolite as choline. The discussion of the mechanistic background for the excretion of choline, which is usually well-conserved in the body, results in two hypotheses of either a massive degradation of cell membranes or an inhibition of the choline oxidation. Although the validation of these hypotheses needs a follow-up study, the finding of a increased excretion of the important metabolite choline warrants exclusion of these two compounds as viable drug candidates from a metabonomics point of view.

Animals↗

Metabolic profiling technologies for biomarker discovery in biomedicine and drug development.

The state-of-the-art of nuclear magnetic resonance spectroscopy, mass spectrometry and statistical tools for the acquisition and evaluation of complex multidimensional spectroscopic data in metabolic profiling is reviewed in this article. The continuous evolution of the sensitivity, precision and throughput has made these technologies powerful and extremely robust tools for application in systems biology, pharmaceutical and diagnostics research. Particular emphasis is also given to the collection and storage of biological samples that are subjected to metabolite profiling. Selected examples from preclinical and clinical applications are paradigmatically shown. These illustrate the power of the profiling technologies for characterizing the metabolic phenotype of healthy, diseased and treated subjects. The complexity of disease and drug treatment is asking for an adequate response by integrated and comprehensive metabolite profiling approaches that allow the discovery of new combinations of metabolic biomarkers.

Animals↗

Quantification of quaternary mixtures of low alcohols in water: temporal-resolved measurements with microporous and hyperbranched polymer sensors for reduction of sensor number.

The focus of this study is the quantification of multianalyte mixtures in water by the use of sensor arrays based on polymer layers. Reflectometric interference spectroscopy is used as a optical sensor system for temporal-resolved measurements of the interaction kinetics of analytes in water with the polymer layers. The principles and widespread possibilities of this approach are demonstrated using the quantification of quaternary aqueous mixtures of low alcohols from methanol up to 1-butanol. The sensitive layers consist of two hyperbranched polyesters and one microporous polyimide. Different time-dependent sensor signals are evaluated by artificial neural networks. Because the kinetics of sorption and desorption of the analytes differ significantly, the number of sensors needed for a quantification of analytes in mixtures can be reduced. A feature extraction allows identification of the most important differences of kinetic patterns of the analytes and allows improvement of the multivariate calibration. It is shown that a quantification of quaternary mixtures of methanol, ethanol, 1-propanol, and 1-butanol is possible on the basis of only two polymer sensors.

Journal Article↗

Different approaches to multivariate calibration of nonlinear sensor data.

In this study, different approaches to the multivariate calibration of the vapors of two refrigerants are reported. As the relationships between the time-resolved sensor signals and the concentrations of the analytes are nonlinear, the widely used partial least-squares regression (PLS) fails. Therefore, different methods are used, which are known to be able to deal with nonlinearities present in data. First, the Box-Cox transformation, which transforms the dependent variables nonlinearly, was applied. The second approach, the implicit nonlinear PLS regression, tries to account for nonlinearities by introducing squared terms of the independent variables to the original independent variables. The third approach, quadratic PLS (QPLS), uses a nonlinear quadratic inner relationship for the model instead of a linear relationship such as PLS. Tree algorithms are also used, which split a nonlinear problem into smaller subproblems, which are modeled using linear methods or discrete values. Finally, neural networks are applied, which are able to model any relationship. Different special implementations, like genetic algorithms with neural networks and growing neural networks, are also used to prevent an overfitting. Among the fast and simpler algorithms, QPLS shows good results. Different implementations of neural networks show excellent results. Among the different implementations, the most sophisticated and computing-intensive algorithms (growing neural networks) show the best results. Thus, the optimal method for the data set presented is a compromise between quality of calibration and complexity of the algorithm.

Journal Article↗

Multi-analyte assay for triazines using cross-reactive antibodies and neural networks.

A biosensor system based on total internal reflectance fluorescence (TIRF) was used to discriminate a mixture of the triazines atrazine and simazine. Only cross-reactive antibodies were available for these two analytes. The biosensor is fully automated and can be regenerated allowing several hundreds of measurements without any user input. Even a remote control for online monitoring in the field is possible. The multivariate calibration of the sensor signal was performed using artificial neural networks, as the relationship between the sensor signals and the concentration of the analytes is highly non-linear. For the development of a multi-analyte immunoassay consisting of two polyclonal antibodies with cross-reactivity to atrazine and simazine and different derivatives immobilised on the transducer surface, the binding characteristics between these substances like binding capacity and cross-reactivity were characterised. The examination of three different measurement procedures showed that a two-step measurement using only one antibody per step allows a quantification of both analytes in a mixture with limits of detection of 0.2 microg/l for atrazine and 0.3 microg/l for simazine. The biosensor is suitable for online monitoring in the field and remote control is possible.

Algorithms↗

Urinary nucleosides as potential tumor markers evaluated by learning vector quantization.

Modified nucleosides were recently presented as potential tumor markers for breast cancer. The patterns of the levels of urinary nucleosides are different for tumor bearing individuals and for healthy individuals. Thus, a powerful pattern recognition method is needed. Although backpropagation (BP) neural networks are becoming increasingly common in medical literature for pattern recognition, it has been shown that often-superior methods exist like learning vector quantization (LVQ) and support vector machines (SVM). The aim of this feasibility study is to get an indication of the performance of urinary nucleoside levels evaluated by LVQ in contrast to the evaluation the popular BP and SVM networks. Urine samples were collected from female breast cancer patients and from healthy females. Twelve different ribonucleosides were isolated and quantified by a high performance liquid chromatography (HPLC) procedure. LVQ, SVM and BP networks were trained and the performance was evaluated by the classification of the test sets into the categories "cancer" and "healthy". All methods showed a good classification with a sensitivity ranging from 58.8 to 70.6% at a specificity of 88.4-94.2% for the test patterns. Although the classification performance of all methods is comparable, the LVQ implementations are superior in terms of more qualitative features: the results of LVQ networks are more reproducible, as the initialization is deterministic. The LVQ networks can be trained by unbalanced sizes of the different classes. LVQ networks are fast during training, need only few parameters adjusted for training and can be retrained by patterns of "local individuals". As at least some of these features play an important role in an implementation into a medical decision support system, it is recommended to use LVQ for an extended study.

Adult↗

Discrimination of methanol and ethanol vapors by the use of a single optical sensor with a microporous sensitive layer.

The sorption of methanol and ethanol vapors by a microporous glassy polycarbonate is studied. The increase of the refractive index of the polymer during analyte sorption is measured by surface plasmon resonance. Both analytes are sorbed into the micropores of the polymer showing different diffusion kinetics. The sensor response during analyte exposure is subdivided into different time channels. By evaluating this additional data dimension by neural networks, a simultaneous multicomponent analysis of binary mixtures of ethanol and methanol vapors is possible using the sensor response of only one single sensor. A feature extraction results in an interpretable model and an improved prediction with errors of 2.0% for methanol and 2.4% for ethanol.

Journal Article↗