Biomedical subjects
Frank Dorman
Publications and source records attributed to Frank Dorman.
Gas chromatography.
Explore the source record for details and available documents.
Design, fabrication, and evaluation of microfabricated columns for gas chromatography.
The design, fabrication, and performance of gas chromatography columns etched in silicon substrates are described. Deep reactive-ion etching formed the 3-m-long, 150-microm-wide, 240-microm-deep rectangular cross section channels. A glass cover plate was anodically bonded to the remaining surface of the substrate forming the gastight channel. For some of the columns, the silicon channels were oxidized before the channels were sealed with the glass plates. Fused-silica capillary connecting tubes were sealed into ports on the edge of the 3.2-cm x 3.2-cm substrate chips. Dynamic coating was used to deposit a film of nonpolar dimethyl polysiloxane or moderately polar trifluoropropylmethyl polysiloxane stationary phase. The columns were evaluated in a conventional benchtop GC instrument with split injection and flame ionization detection. Column efficiency was evaluated by the use of plots of height equivalent to a theoretical plate versus average carrier gas velocity using both hydrogen and air as carrier gases. The number of theoretical plates measured at the average carrier gas velocity giving the minimum plate height ranged from 4600 to 8200 plates for the dimethyl polysiloxane columns and from 3500 to 5500 plates for the trifluoropropylmethyl polysiloxane columns. Minimum plate height was significantly smaller with air as carrier gas. For the nonpolar phase, the nonoxidized surface gave approximately 1500 plates more than the oxidized surface for both carrier gases. For the polar phase, the oxidized surface gave approximately 200 plates more than the nonoxidized surface. Isothermal chromatograms of a 20-component multifunctional mixture and temperature-programmed chromatograms of a normal alkane mixture are presented.
Sampling and monitoring of biogenic emissions by eucalyptus leaves using membrane extraction with sorbent interface (MESI).
Membrane extraction with sorbent interface (MESI) has been applied to monitor plant fragrance volatiles emitted into indoor air. The main components of the MESI system are a membrane module and a trap, which can be connected directly to a GC or GC-MS for simultaneous multicomponent extraction and monitoring. A polydimethylsiloxane (PDMS) membrane and two different traps, PDMS and Tenax, as well as a DC current supply for trap desorption have been applied in this research. After the membrane module is placed in contact with the plant, the MESI/GC-MS provides semicontinuous characterization of volatile compounds emitted. The MESI device has been applied to monitor the biogenic volatile organic compounds released during the first 8 h after a branch was cut from a Eucalyptus dunnii tree. The study demonstrates that the MESI system is a simple and useful tool for monitoring changes in emission processes as a function of time.
Gas chromatography.
Explore the source record for details and available documents.