PubMed Health⌕ Search

Biomedical subjects

Frank Engelke

Publications and source records attributed to Frank Engelke.

4 recordsLinked to original sources

Development of a dual cell, flow-injection sample holder, and NMR probe for comparative ligand-binding studies.

NMR based ligand screening is becoming increasingly important for the very early stages of drug discovery. We have proposed a method that makes highly efficient use of a single sample of a scarce target, or one with poor or limited solubility, to screen an entire compound library. This comparative method is based on immobilizing the target for the screening procedure. In order to support the method, a dual cell, flow injection probe with a single receiver coil has been constructed. The flow injection probe has been mated to a single high performance pump and sample handling system to enable the automated analysis of large numbers of compound mixes for binding to the target. The probe, having an 8 mm 1H/2H dual tuned coil and triple axis gradients, is easily shimmed and yields NMR spectra of comparable quality to a standard 5 mm high-resolution probe. The lineshape in the presence of a solid support is identical to that in glass NMR tubes in a 5 mm probe. Control spectra of each cell are identical and well separated, while ligand binding in a complex mixture can be readily detected in 20-30 min, thus paving the way for use of the probe for actual drug discovery efforts.

Binding Sites↗

Field modulation effects induced by sample spinning: application to high-resolution magic angle spinning NMR.

High-resolution magic angle spinning (HRMAS) has become an extremely versatile tool to study heterogeneous systems. HRMAS relies on magic angle spinning of the sample and on pulse sequences originally developed for liquid state NMR. In most cases the outcome of the experiment is conform to what is expected from high-resolution liquid state NMR spectroscopy. However in some instances, experiments run under MAS can produce some very puzzling results. After reviewing the basic hardware which is at the heart of HRMAS spectroscopy, we show that the origin of this behavior lies in the natural time-dependence of some physical quantities imparted by the rotation. We focus in particular on the effects of B1 inhomogeneities on the nutation, the (90 degrees)+x-t-(90 degrees )-x and the MLEV16 experiments. Different models of radiofrequency distribution of B1 fields in a solenoidal coil are derived from simple geometrical considerations. These models are shown by NMR spin dynamics calculations to reproduce the experimental NMR results. They are also consistent with electromagnetic simulations of the B1 field distribution inside a solenoidal coil.

Electromagnetic Phenomena↗

Studying lateral diffusion in lipid bilayers by combining a magic angle spinning NMR probe with a microimaging gradient system.

An alternative technique for studying the lateral diffusion in lipid membranes using pulsed field gradients in combination with magic angle spinning is presented. It is shown that MAS probes inserted in a microimaging device that produce high field gradients can be used to monitor also slow diffusion processes. As an example, measurements of the lateral diffusion of lipids embedded in the bilayer of a cubic phase are presented.

Diffusion↗

1H detection in MAS solid-state NMR spectroscopy of biomacromolecules employing pulsed field gradients for residual solvent suppression.

In this communication, we demonstrate the feasibility of 1H detection in MAS solid-state NMR for a microcrystalline, uniformly 2H,15N-labeled sample of a SH3 domain of chicken alpha-spectrin, using pulsed field gradients for suppression of water magnetization. Today, B0 gradients are employed routinely in solution-state NMR for coherence order selection and solvent suppression. We suggest to use gradients to purge water magnetization which cannot be suppressed using conventional water suppression schemes. The achievable gain in sensitivity for 1H detection is in the order of 5 compared to the 15N detected version of the experiment (at a MAS rotation frequency of 13.5 kHz). We expect that this labeling concept which achieves high sensitivity due to 1H detection, in combination with the possibility to measure long range 1H-1H distances as we have shown previously, to be a useful tool for the determination of protein structures in the solid state.

Animals↗