Frank Fischbach

Publications and source records attributed to Frank Fischbach.

8 recordsLinked to original sources

High-resolution MRI of the wrist and finger joints in patients with rheumatoid arthritis: comparison of 1.5 Tesla and 3.0 Tesla.

The goal of this study was to compare magnetic resonance (MR) image quality at different field strengths for evaluating lesions in wrist and finger joints of patients with rheumatoid arthritis (RA) in order to determine whether the higher field strength provides diagnostic gain. The hand mainly affected in 17 RA patients was examined at 1.5 Tesla (T) and 3.0 T with comparable MR imaging (MRI) protocols. MR images were reviewed twice by two experienced radiologists using the Rheumatoid Arthritis MRI Scoring System (RAMRIS) of the OMERACT (Outcome Measures in Rheumatoid Arthritis Clinical Trials) group. Image quality was rated on a five-point scale using Friedmann's test and Kendall's W-test for statistical analysis. Image comparison revealed better image quality at higher field strength. Image quality of T1-weighted images was rated 14-22% better at 3.0 T compared with 1.5 T by both readers. Moreover, the rating for the T2-weighted-images acquired at 3.0 T was one point better in the five-point scale used. Inter-reader correlation for image quality, bone erosions/defects, edema and synovitis ranged between 0.6 and 0.9 at 3.0 T and between 0.6 and 0.8 at 1.5 T. Intra-reader correlation for these parameters was high at 0.8-1.0. MRI image quality of RA hands is superior at 3.0 T, while an acceptable image quality is achieved at 1.5 T, which improves the evaluation of extent of bone edema, synovitis and identification of small bone erosions.

Adult↗

Value of axial and coronal maximum intensity projection (MIP) images in the detection of pulmonary nodules by multislice spiral CT: comparison with axial 1-mm and 5-mm slices.

The purpose of this study was to investigate the diagnostic accuracy of non-overlapping 10-mm axial and coronal maximum intensity projections (MIP) in comparison with standard axial 1-mm and 5-mm slices in the detection of pulmonary nodules. Sixty patients with suspected nodules who underwent multislice spiral CT of the chest were evaluated. Axial 1-mm and 5-mm slices as well as non-overlapping 10-mm axial/coronal MIPs were interpreted independently by three blinded radiologists. After initial review, a retrospective consensus session was performed for agreement on final nodule counts using the axial 1-mm slices as gold standard. Small nodules of less than 5 mm in size were most accurately detected by the axial MIPs. Receiver operating characteristic (ROC) analysis of these small nodules showed that 5-mm slices were not capable of a statistically significant differentiation of nodules from other focal lesions in two observers (p=0.034 and p=0.012, respectively) whereas 1-mm slices and coronal/axial MIPs did allow a statistically significant differentiation in all observers (p<0.001). Nodules larger than 5 mm were equally well depicted with all modalities. Non-overlapping 10-mm axial MIPs improve the accuracy in the detection of small pulmonary nodules.

Adolescent↗

Clinical results of CsI-detector-based dual-exposure dual energy in chest radiography.

The aim of this study was to compare the sensitivity and specificity of digital chest radiography alone with digital chest radiography combined with dual-energy chest radiography in the detection of small non-calcified pulmonary nodules. Standard and dual-energy radiographs were obtained with a flat-panel digital chest system. Four radiologists reviewed digital posteroanterior chest radiographs in random order either alone or in conjunction with dual-energy soft tissue and bone images. Twenty patients with a total of 59 pulmonary nodules (median 0.5 cm, range 0.3-2.5 cm) confirmed by computed tomography (HU < or =100) were included. A level of confidence for each diagnosis was documented using a rating scale of 1-5. Brunner and Langer's test was performed for statistical analysis. Subgroup analysis was performed for nodules greater than 1 cm, 1-0.5 cm, and <0.5 cm. For posteroanterior chest radiography, sensitivity was 33%, positive predictive value 83%, specificity 81%, and negative predictive value 30%. Review in conjunction with dual-energy images resulted in a sensitivity of 42%, positive predictive value 88%, specificity 85%, and negative predictive value 34%. The increase of nodule detection overall as well as for different size categories was significant (p<0.05). The increase of the confidence level rating was also significant (p<0.001). Dual energy added to standard posteroanterior chest radiography significantly improves the sensitivity, specificity, and confidence in detection of small non-calcified pulmonary nodules.

Humans↗

Detection of pulmonary nodules by multislice computed tomography: improved detection rate with reduced slice thickness.

The purpose of this study was to find out if the use of 1.25-mm collimated thin-slice technique helps to detect more small pulmonary lung nodules than the use of 5 mm. A total of 100 patient examinations that allowed a reconstruction of 1.25-mm slice thickness in addition to the standard of 5-mm slices were included in a prospective study. Acquisition technique included four rows of 1-mm slices. Two sets of contiguous images were reconstructed and compared with 1.25- and 5-mm slice thickness, respectively. Two radiologists performed a film-based analysis of the images. The size and the confidence of the seen nodules were reported. We did not perform a histological verification, according to the normal clinical procedure, although it would be optimal regarding research. Statistical analysis was performed by using longitudinal analysis described by Brunner and Langer. In addition, sensitivity, specificity, negative predictive value and positive predictive value were calculated for each reader using the 1.25-mm sections as the gold standard. As an index for concordance the kappa value was used. A value of p<0.05 was regarded as significant. In 37 patients pulmonary nodules were detected. Twenty-four patients showed more than one nodule; among these, 7 patients had disseminated disease and were excluded from the study. Pulmonary nodules larger than 10 mm in size were equally well depicted with both modalities, whereas lesions smaller than 5 mm in size were significantly better depicted with 1.25 mm (p<0.05). Using 1.25 mm as the gold standard, sensitivity for 5-mm reconstruction interval was 88 and 86% for observers A and B, respectively. No false-positive results were reported for 5-mm sections. Interobserver agreement for nodule detection determined for 1.25-mm reconstruction intervals showed a k value of 0.753, indicating a good agreement, and 0.562 for 5-mm reconstruction intervals, indicating a moderate agreement. Brunner and Langer analysis showed significant differences for slice thickness and no significant difference between the observers. Reduced slice thickness demonstrated an improvement of small nodule detection, confidence levels, and interobserver agreement. Application of thin-slice multidetector-row CT may raise the sensitivity for lung nodule detection, although the higher detection rate of smaller nodules has to be evaluated from a clinical perspective and remains problematic about how the detection of small nodules will effect patient outcome.

Adult↗

Dual-energy chest radiography with a flat-panel digital detector: revealing calcified chest abnormalities.

OBJECTIVE: The aim of this study was to assess the value of dual-energy chest radiography obtained using a cesium iodide flat-panel detector in addition to standard posteroanterior chest radiography for the detection of calcified chest abnormalities. MATERIALS AND METHODS: The study included 20 patients with a total of 37 calcified chest lesions (16 pulmonary nodules, 17 mediastinal calcifications, and four pleural calcifications) as confirmed on CT. Twenty-eight locations in the chests of the same patients who were free of lesions were used as negative controls. Four radiologists reviewed posteroanterior chest radiographs in a blinded manner alone and in conjunction with dual-energy soft-tissue and bone images. We calculated sensitivity, specificity, the negative predictive value (NPV), and the positive predictive value (PPV) for lesion prediction. The Wilcoxon's and the Brunner and Langer's tests were performed for statistical analysis. RESULTS: For posteroanterior chest radiography, sensitivity was 36%, the PPV was 64%, and the NPV was 47%. When dual-energy images were added, sensitivity increased significantly to 66% (p < 0.05), the PPV to 76%, and the NPV to 62%. The specificity remained constant at 73%. Brunner and Langer's test revealed a highly significant difference between posteroanterior chest radiography and dual-energy imaging in the detection of calcified chest abnormalities (p < 0.01). CONCLUSION: Dual-energy images added to standard posteroanterior chest radiographs significantly improve the detection of calcified chest lesions.

Aged↗

Flat panel digital radiography compared with storage phosphor computed radiography: assessment of dose versus image quality in phantom studies.

RATIONALE AND OBJECTIVE: To assess and quantify the dose reduction by use of a CsI-flat panel digital radiography (DR)-system compared with digital computed radiography (CR). MATERIALS AND METHODS: A TCDD-test using the CDRAD-phantom was performed at mAs-values of 5, 4, 2.5, 2, 1, and 0.5 mAs for both digital systems. Entrance surface doses were recorded for all images. Images were presented to four independent observers. For quantitative comparison the image quality figure (IQF) was calculated. Statistical analysis was performed using the Pearson correlation and the Wilcoxon test. A ROC analysis was performed using the TRG-phantom. Settings of 4, 2.5, 2 mAs for both systems were used. In addition, 1 and 0.5 mAs were used for the DR system only. Statistical significance was evaluated using Student test. RESULTS: The DR system provided equivalent results compared with CR with respect to high frequency information and superior results with respect to low contrast details. Compared with computed radiography, the flat panel detector demonstrated significantly lower IQFs, ensuring a better image quality with respect to contrast and detail detectability. IQFs for DR and CR were equal at a surface dose reduction of 87% for DR. ROC analysis revealed significantly higher values under the curve for DR up to a surface dose reduction of 70%. CONCLUSIONS: Image quality of DR proved to be far superior to CR in particular for low contrast details. The image quality of CR is similar to that of DR only at high dose levels.

Phantoms, Imaging↗

CT colonography using different reconstruction modi.

OBJECTIVE: Performing computed tomography (CT) colonography, we compared different reconstruction modi for the detection of colorectal polyps. METHODS: The CT data of 48 patients using 16-slice helical CT were analysed in axial slices, virtual-endoscopy and colon-dissection modus. RESULTS: The sensitivity (specificity) for the detection of colonic polyps was 94% (80%) if using "colonic-dissection" tool and 89% (80%) if using "virtual-endoscopy" tool. The difference between the virtual endoscopy and colon dissection, considering polyps up to 4.9 mm, was significant. CONCLUSIONS: Reconstruction software colon dissection improves the sensitivity of CT colonography.

Colonic Polyps↗

Efficacy of contrast medium use for neuroimaging at 3.0 T: utility of IR-FSE compared to other T1-weighted pulse sequences.

As inversion-recovery (IR) technique improves T1 contrast at high field strength, signal enhancement by T1-shortening contrast media may be affected. To clarify the different enhancement properties at 3.0 T, the authors compared T1-weighted sequences. Twelve contrast-enhancing lesions were investigated by spin-echo (SE), inversion recovery fast spin-echo (IR-FSE), two-dimensional gradient-echo (2D GE), and magnetization-prepared three-dimensional gradient-echo (3D GE) sequences and evaluated by comparing signal-intensity enhancements within the lesions. In addition, signal-to-noise-ratios (SNR) and contrast-to-noise-ratios (CNR) were measured. On average, signal enhancement of the lesions amounted to 60% for SE, 57% for IR-FSE, 32% for 2D GE, and 35% for 3D GE images. CNR of gray matter versus white matter was significantly higher for IR SE and GE imaging than for genuine SE and 2D GE acquisitions (Wilcoxon test), while 2D GE imaging alone had an excellent SNR. As IR-FSE images provide an excellent CNR for gray and white matter in the brain and contrast enhancement performs almost similarly well compared with SE imaging, this technique appears to be well suited for T1-weighted neuroimaging without and with contrast enhancement at 3.0 T. However, the inherent blurring of the IR-FSE can lead to poor performance for very small lesions.

Adult↗