Intraoperative navigated 3-dimensional ultrasound angiography in tumor surgery.

BACKGROUND: Avoiding damage to blood vessels is often the concern of the neurosurgeon during tumor surgery. Using angiographic image data in neuronavigation may be useful in cases where vascular anatomy is of special interest. Since 2003, we have routinely used 3D ultrasound angiography in tumor surgery, and between January 2003 and May 2005, 62 patients with different tumors have been operated using intraoperative 3D ultrasound angiography in neuronavigation. METHODS: An ultrasound-based neuronavigation system was used. In addition to 3D ultrasound tissue image data, 3D ultrasound angiography (power Doppler) image data were acquired at different stages of the operation. The value and role of navigated 3D ultrasound angiography as judged by the surgeon were recorded. RESULTS: We found that intraoperative ultrasound angiography was easy to acquire and interpret, and that image quality was sufficient for neuronavigation. In 26 of 62 cases, ultrasound angiography was found to be helpful by visualizing hidden vessels adjacent to and inside the tumor, facilitating tailored approaches and safe biopsy sampling. CONCLUSIONS: Intraoperative 3D ultrasound angiography is straightforward to use, image quality is sufficient for image guidance, and it adds valuable information about hidden vessels, increasing safety and facilitating tailored approaches. Furthermore, with updated 3D ultrasound angiography imaging, accuracy of neuronavigation may be maintained in cases of brain shift.

Biopsy↗

A review of calibration techniques for freehand 3-D ultrasound systems.

Three-dimensional (3-D) ultrasound (US) is an emerging new technology with numerous clinical applications. Ultrasound probe calibration is an obligatory step to build 3-D volumes from 2-D images acquired in a freehand US system. The role of calibration is to find the mathematical transformation that converts the 2-D coordinates of pixels in the US image into 3-D coordinates in the frame of reference of a position sensor attached to the US probe. This article is a comprehensive review of what has been published in the field of US probe calibration for 3-D US. The article covers the topics of tracking technologies, US image acquisition, phantom design, speed of sound issues, feature extraction, least-squares minimization, temporal calibration, calibration evaluation techniques and phantom comparisons. The calibration phantoms and methods have also been classified in tables to give a better overview of the existing methods.

Algorithms↗

A review of calibration techniques for freehand 3-D ultrasound systems.

Three-dimensional (3-D) ultrasound (US) is an emerging new technology with numerous clinical applications. Ultrasound probe calibration is an obligatory step to build 3-D volumes from 2-D images acquired in a freehand US system. The role of calibration is to find the mathematical transformation that converts the 2-D coordinates of pixels in the US image into 3-D coordinates in the frame of reference of a position sensor attached to the US probe. This article is a comprehensive review of what has been published in the field of US probe calibration for 3-D US. The article covers the topics of tracking technologies, US image acquisition, phantom design, speed of sound issues, feature extraction, least-squares minimization, temporal calibration, calibration evaluation techniques and phantom comparisons. The calibration phantoms and methods have also been classified in tables to give a better overview of the existing methods.

Algorithms↗

Operation of arteriovenous malformations assisted by stereoscopic navigation-controlled display of preoperative magnetic resonance angiography and intraoperative ultrasound angiography.

OBJECTIVE: To study the application of navigated stereoscopic display of preoperative three-dimensional (3-D) magnetic resonance angiography and intraoperative 3-D ultrasound angiography in a clinical setting. METHODS: Preoperative magnetic resonance angiography and intraoperative ultrasound angiography are presented as stereoscopic images on the monitor during the operation by a simple red/blue technique. Two projections are generated, one for each eye, according to a simple ray casting method. Because of integration with a navigation system, it is possible to identify vessels with a pointer. The system has been applied during operations on nine patients with arteriovenous malformations (AVMs). Seven of the patients had AVMs in an eloquent area. RESULTS: The technology makes it easier to understand the vascular architecture during the operation, and it offers a possibility to identify and clip AVM feeders both on the surface and deep in the tissue at the beginning of the operation. All 28 feeders identified on the preoperative angiograms were identified by intraoperative navigated stereoscopy. Twenty-five were clipped at the beginning of the operation. The other three were clipped at a later phase of the operation. 3-D ultrasound angiography was useful to map the size of the nidus, to detect the degree of brain shift, and to identify residual AVM. CONCLUSION: Stereoscopic visualization enhances the surgeon's perception of the vascular architecture, and integrated with navigation technology, this offers a reliable system for identification and clipping of AVM feeders in the initial phase of the operation.

Adult↗

A robust and automatic method for evaluating accuracy in 3-D ultrasound-based navigation.

We present a robust and automatic method for evaluating the 3-D navigation accuracy in ultrasound (US) based image-guided systems. The method is based on a precisely built and accurately measured phantom with several wire crosses and an automatic 3-D template matching by correlation algorithm. We investigated the accuracy and robustness of the algorithm and also addressed optimization of algorithm parameters. Finally, we applied the method to an extensive data set from an in-house US-based navigation system. To evaluate the algorithm, eight skilled observers identified the same wire crosses manually and the average over all observers constitutes our reference data set. We found no significant differences between the automatic and the manual procedures; the average distance between the point sets for one particular volume (27 point pairs) was 0.27 +/- 0.17 mm. Furthermore, the spread of the automatically determined points compared with the reference set was lower than the spread for any individual operator. This indicates that the automatic algorithm is more accurate than manual determination of the wire-cross locations, in addition to being faster and nonsubjective. In the application example, we used a set of 35 3-D US scans of the phantom under various acquisition configurations. The US frequency was 6.7 MHz and the average target depth was 6 cm. The accuracy, represented by the mean distance between automatically-determined wire-cross locations and physically measured locations, was found to be 1.34 +/- 0.62 mm.

Algorithms↗

Probe calibration for freehand 3-D ultrasound.

Ultrasound (US) probe calibration establishes the rigid body transformation between the US image and a tracking device attached to the probe. This is an important requirement for correct 3-D reconstruction of freehand US images and, thus, for accurate surgical navigation based on US. In this study, we evaluated three methods for probe calibration, based on a single-point phantom, a wire-cross phantom requiring 2-D alignment and a wire phantom for freehand scanning. The processing of acquired data is fairly common to these methods and, to a great extent, based on automated procedures. The evaluation is based on quality measures in 2-D and 3-D reconstructed data. With each of the three methods, we calibrated a linear-array probe, a phased-array sector probe and an intraoperative probe. The freehand method performed best, with a 3-D navigation accuracy of 0.6 mm for one of the probes. This indicates that clinical accuracy in the order of 1 mm may be achieved in US-based surgical navigation.

Calibration↗

Multimodal image fusion in ultrasound-based neuronavigation: improving overview and interpretation by integrating preoperative MRI with intraoperative 3D ultrasound.

OBJECTIVE: We have investigated alternative ways to integrate intraoperative 3D ultrasound images and preoperative MR images in the same 3D scene for visualizing brain shift and improving overview and interpretation in ultrasound-based neuronavigation. MATERIALS AND METHODS: A Multi-Modal Volume Visualizer (MMVV) was developed that can read data exported from the SonoWand neuronavigation system and reconstruct the spatial relationship between the volumes available at any given time during an operation, thus enabling the exploration of new ways to fuse pre- and intraoperative data for planning, guidance and therapy control. In addition, the mismatch between MRI volumes registered to the patient and intraoperative ultrasound acquired from the dura was qualified. RESULTS: The results show that image fusion of intraoperative ultrasound images in combination with preoperative MRI will make perception of available information easier by providing updated (real-time) image information and an extended overview of the operating field during surgery. This approach will assess the degree of anatomical changes during surgery and give the surgeon an understanding of how identical structures are imaged using the different imaging modalities. The present study showed that in 50% of the cases there were indications of brain shift even before the surgical procedure had started. CONCLUSIONS: We believe that image fusion between intraoperative 3D ultrasound and preoperative MRI might improve the quality of the surgical procedure and hence also improve the patient outcome.

Brain↗

Accuracy evaluation of a 3D ultrasound-based neuronavigation system.

We have investigated the 3D navigation accuracy of a frameless ultrasound-based neuronavigation system (SonoWand) for surgical planning and intraoperative image guidance. In addition, we present a detailed description and review of the error sources associated with surgical neuronavigation based on preoperative MRI data and intraoperative ultrasound. A phantom with 27 precisely defined points was scanned with ultrasound by various translation and tilt movements of the ultrasound probe (180 3D scans in total), and the 27 image points in each volume were located using an automatic detection algorithm. These locations were compared to the physically measured locations of the same 27 points. The accuracy of the neuronavigation system and the effect of varying acquisition conditions were found through a thorough statistical analysis of the differences between the two point sets. The accuracy was found to be 1.40 +/- 0.45 mm (arithmetic mean) for the ultrasound-based neuronavigation system in our laboratory setting. Improper probe calibration was the major contributor to this figure. Based on our extensive data set and thorough evaluation, the accuracy found in the laboratory setting is expected to be close to the overall clinical accuracy for ultrasound-based neuronavigation. Our analysis indicates that the overall clinical accuracy may be as low as 2 mm when using intraoperative imaging to compensate for brain shift.

Humans↗