Rapid online-SPE-MS/MS method for ketoprofen determination in dermal interstitial fluid samples from rats obtained by microdialysis or open-flow microperfusion.

Pharmacokinetic studies of topical ketoprofen formulations using continuous sampling techniques such as microdialysis (MD) or open-flow microperfusion (OFM) require sensitive assays due to small sample volumes. A simple and easy online-SPE-MS/MS method for ketoprofen analysis was developed for both MD and OFM samples obtained from rat dermal tissue. The quantification range is 25-5000 ng/ml with a limit of detection of 3 ng/ml using only 10 microl sample volume. The method is characterized by a simple setup using a short polymeric SPE column (OASIS HLB) for desalting with 1.5 min run times in combination with a sensitive MS detection in negative ESI MRM mode. An easy sample workup procedure was used which enables high throughput analysis of a large number of samples for pharmacokinetic studies. In addition, a commercial available (fenoprofen) as well as an isotopically labelled (deuterated ketoprofen) standard were investigated as potential internal standards. The method was validated according to FDA guidelines for bioanalytical validation in terms of accuracy, intra-batch and inter-batch precision, linearity, matrix effect, recovery and stability for both internal standards. Accuracies were 98-113% (fenoprofen) and 95-108% (deuterated ketoprofen), intra-batch precision was 2-3% R.S.D. (fenoprofen) and 2-6% R.S.D. (deuterated ketoprofen), and inter-batch precision was 2-6% R.S.D. (fenoprofen) and 3-6% R.S.D. (deuterated ketoprofen) over the entire quantification range. The presented method was applied to dermal interstitial fluid samples obtained in a topical administration study of ketoprofen in rats.

Animals↗

Poly(cyclooctene)-based monolithic columns for capillary high performance liquid chromatography prepared via ring-opening metathesis polymerization.

Monolithic columns for capillary HPLC were prepared via ring-opening metathesis polymerization (ROMP) from cis-cyclooctene (COE), tris(cyclooct-4-enyl-1-oxy)methylsilane (CL) as monomers, 2-propanol and toluene as porogens and RuCl(2)(Py)(2)(IMesH(2))(CHC(6)H(5)) (Py=pyridine, IMesH(2)=1,3-dimesityl-4,5-dihydroimidazolin-2-ylidene) as initiator within the confines of 200 microm i.d. fused silica columns. For evaluation of the novel monolithic capillary HPLC columns, a protein standard consisting of six proteins in the molecular weight range of 5800-66000 g/mol, i.e. ribonuclease A, insulin, albumin, lysozyme, myoglobin and beta-lactoglobulin, was used. Reproducibility of synthesis was checked by determining the relative standard deviation (RSD) in retention times (t(R)), which was found to be in the range of 2.9-3.9% for all analytes. Variations in polymer kinetics were realized by adding different amounts of free pyridine and had a significant influence on the monolith's morphology, the backpressure and retention times. On the contrary, variations in monomer content and COE to CL ratio showed only minor changes on these parameters. Long-term stability of 1000 runs at 50 degrees C showed excellent stability of the columns and no significant alteration in separation performance was observed in combination with slightly decreased retention times (approx. 1.6-7.2% for all analytes).

Chromatography, High Pressure Liquid↗

Enantioseparation of glycyl-dipeptides by CEC using particle-loaded monoliths prepared by ring-opening metathesis polymerization (ROMP).

Novel particle-loaded monolithic capillary electrochromatography (CEC) phases for chiral separations were prepared via ring-opening metathesis polymerization (ROMP) within the confines of fused silica columns with 200 microm i.d. using norborn-2-ene (NBE), 1,4,4a,5,8,8a-hexahydro-1,4,5,8,exo,endo-dimethanonaphthalene (DMN-H6) as monomers, 2-propanol and toluene as porogens, RuCl2(PCy3)2(CHPh) as initiator and silica-based particles containing the chiral selector. By suspending silica particles bearing the chiral selector in the polymerization mixture, particle-based monoliths are easily prepared. This approach has several advantages compared to particle-based separation media: (i) the concept of particle-based monoliths is broadly applicable, as any silica-based chiral phase can be used; (ii) they are inexpensive to prepare; and (iii) the manufacturing process is very simple, no sophisticated packing procedures or the preparation of end frits are required. To show the usefulness of this concept for chiral CEC, the chiral separation performance of particle-loaded CEC monoliths bearing teicoplanin aglycone, chemically bonded to 3 microm silica gel, was investigated for a set of glycyl-dipeptides. Particle-loaded ROMP CEC monoliths showed good separation performance for glycyl-dipeptides.

Capillary Electrochromatography↗

Evaluation of ring-opening metathesis polymerization (ROMP)-derived monolithic capillary high performance liquid chromatography columns.

Novel monolithic capillary HPLC columns were prepared via ring opening metathesis polymerization (ROMP) within the confines of fused silica columns with 200 microm i.d. using norborn-2-ene (NBE), 1,4,4a,5,8,8a-hexahydro-1,4,5,8, exo, endo-dimethanonaphthalene (DMN-H6) as monomers, 2-propanol and toluene as porogens and RuCl2(PCy3)2(CHPh) as initiator. Using the monolithic capillary HPLC columns, different sets of analytes (i.e. standard systems) were used for the evaluation of the monolithic columns: (i) a protein standard consisting of six proteins in the range of 5000-66 000 g/mol, (ii) an insulin-albumin standard, and (iii) a peptide standard obtained from a tryptic digest of cytochrome C. With these three different standard systems the reproducibility of synthesis in terms of separation performance proved to be 1-2% relative standard deviation in tR. Variation of polymerization parameters had a significant influence on the monolithic morphology and therefore separation efficiency and back pressure. The maximum analytical loading capacity of ROMP-derived monolithic capillary columns for albumin was found to be 30-125 ng, depending on the monomer content. Long-term stability studies showed no alteration in separation performance.

Bridged Bicyclo Compounds↗

LC/MS/MS method for quantitative determination of long-chain fatty acyl-CoAs.

Long-chain acyl-CoA esters (LCACoAs) are activated lipid species that represent key substrates in lipid metabolism. The relationship between lipid metabolism disorders and type 2 diabetes has attracted much attention to this class of metabolites. This paper presents a highly sensitive and robust on-line LC/MS(2) procedure for quantitative determination of LCACoAs from rat liver. A fast SPE method has been developed without the need for time-consuming evaporation steps for sample preparation. LCACoAs were separated with high resolution using a C18 reversed-phase column at high pH (10.5) with an ammonium hydroxide and acetonitrile gradient. Five LCACoAs (C16:0, C16:1, C18:0 C18:1, C18:2) were quantified by selective multireaction monitoring using a triple quadrupole mass spectrometer in positive electrospray ionization mode. It is possible to perform a neutral loss scan of 507 for lipid profiling of complex LCACoA mixtures in tissue extracts. The method presented was validated according to ICH guidelines for quantitative determination of five LCACoAs for physiological concentrations in 100-200 mg of tissue with accuracies ranging from 94.8 to 110.8%, interrun precisions between 2.6 and 12.2%, and intrarun precisions between 1.2 and 4.4%. Due to the high sensitivity of the developed method, the amount of tissue biopsied for reliable quantification can be reduced. This may be advantageous in the quantification of LCACoAs in humans.