Ultrasound-based image guided radiotherapy for prostate cancer: comparison of cross-modality and intramodality methods for daily localization during external beam radiotherapy.

PURPOSE: To compare two different ultrasound-based verification systems for prostate alignment during daily external beam radiation therapy (EBRT) for localized prostate cancer. METHODS AND MATERIALS: Prostate displacements were measured prospectively in 40 patients undergoing daily EBRT. Comparison was made between a system based on the cross-modality verification method (CMVM), which uses two different imaging modalities to assess organ motion, and a system based on the intramodality verification method (IMVM), which uses only one imaging modality for such assessment. A total of 217 CMVM and 217 IMVM displacements were collected within a minute of each other. In 10 patients, IMVM displacements were also compared with those measured by sequential CT scans. RESULTS: Analysis in the paired CMVM and IMVM displacements shows a significant mean difference of 0.9 +/- 3.3 mm in the lateral and 6.0 +/- 5.1 mm in the superoinferior directions (p < 0.0001), whereas no significant difference was detected in the anteroposterior direction between the two methods. Comparison of the computed tomography scan and IMVM measured displacements shows no significant difference between the two methods, with mean values of 0.2 +/- 1.7 mm in the lateral, -0.3 +/- 1.6 mm in the anteroposterior, and 0.1 +/- 1.4 mm in the superoinferior directions. CONCLUSIONS: A significant systematic difference exists between cross-modality and intramodality methods when assessing prostate alignment during daily EBRT. Because displacements assessed by IMVM are consistent with those assessed by computed tomography scan, a more accurate prostate alignment appears to be obtained when the IMVM method is used.

Humans↗

RadSim: a program to simulate individual particle interactions for educational purposes.

A program was developed, RadSim, which can be used to simulate certain individual interactions of photons, electrons, positrons and alpha particles with a single atom for educational purposes. The program can be run in two modes: manual and simulated. In the manual mode, an individual particle undergoing a specified interaction with a target atom can be simulated, which essentially comes down to a graphical evaluation of kinematic equations. In the simulated mode, a preset number of identical particles are allowed to undergo a specified interaction type with a target atom. The exit channel of the interaction is sampled from probability distributions using Monte Carlo methods. The incoming and outgoing particles are visualized and the frequency distribution of the kinematic variables of the exit channel is displayed graphically. It has to be emphasized that RadSim was mainly developed for educational purposes.

Computer Simulation↗

Radiation induced currents in parallel plate ionization chambers: measurement and Monte Carlo simulation for megavoltage photon and electron beams.

Polarity effects in ionization chambers are caused by a radiation induced current, also known as Compton current, which arises as a charge imbalance due to charge deposition in electrodes of ionization chambers. We used a phantom-embedded extrapolation chamber (PEEC) for measurements of Compton current in megavoltage photon and electron beams. Electron contamination of photon beams and photon contamination of electron beams have a negligible effect on the measured Compton current. To allow for a theoretical understanding of the Compton current produced in the PEEC effect we carried out Monte Carlo calculations with a modified user code, the COMPTON/ EGSnrc. The Monte Carlo calculated COMPTON currents agree well with measured data for both photon and electron beams; the calculated polarity correction factors, on the other hand, do not agree with measurement results. The conclusions reached for the PEEC can be extended to parallel-plate ionization chambers in general.

Artifacts↗

Characterization of scattered radiation in kV CBCT images using Monte Carlo simulations.

Kilovoltage (kV) cone beam computed tomography (CBCT) images suffer from a substantial scatter contribution. In this study, Monte Carlo (MC) simulations are used to evaluate the scattered radiation present in projection images. These predicted scatter distributions are also used as a scatter correction technique. Images were acquired using a kV CBCT bench top system. The EGSnrc MC code was used to model the flat panel imager, the phantoms, and the x-ray source. The x-ray source model was validated using first and second half-value layers (HVL) and profile measurements. The HVLs and the profile were found to agree within 3% and 6%, respectively. MC simulated and measured projection images for a cylindrical water phantom and for an anthropomorphic head phantom agreed within 8% and 10%. A modified version of the DOSXYZnrc MC code was used to score phase space files with identified scattered and primary particles behind the phantoms. The cone angle, the source-to-detector distance, the phantom geometry, and the energy were varied to determine their effect on the scattered radiation distribution. A scatter correction technique was developed in which the MC predicted scatter distribution is subtracted from the projections prior to reconstruction. Preliminary testing of the procedure was done with an anthropomorphic head phantom and a contrast phantom. Contrast and profile measurements were obtained for the scatter corrected and noncorrected images. An improvement of 3% for contrast between solid water and a liver insert and 11% between solid water and a Teflon insert were obtained and a significant reduction in cupping and streaking artifacts was observed.

Algorithms↗

Relative biologic effectiveness in terms of tumor response of 125I implants compared with 60Co gamma rays.

PURPOSE: To measure the relative biologic effectiveness (RBE) for 125I seeds compared with external beam radiotherapy using a clinically relevant in vivo system. METHODS AND MATERIALS: Photon emission from a detailed source model was simulated using the Monte Carlo code MCNP4C, sampling from a 125I spectrum. The mouse RIF-1 tumor was treated with either temporary implant of an 125I seed or with 60Co gamma rays. The tumors were always the same size at the initiation of treatment, and the endpoint was growth inhibition. RESULTS: The dose-response curve for both modalities was close to linear and was independent of the initial 125I activity (dose rate) for the range investigated. Calculation of the RBE for tumor response requires assigning a unique value for the tumor dose that is not homogenous but depends on the distance from the 125I source. Because tumor regrowth will depend on the subpopulation of cells that have the greatest probability of survival (i.e., those at the greatest distance from the 125I source), one approach is to use the dose to this population. On this basis, the RBE for 125I compared with 60Co gamma rays is 1.5. If the 125I dose is computed as the average dose to the tumor, corrected for the dose that is wasted as overkill in the cell population closest to the center of the 125I seed, the RBE is 1.4. CONCLUSION: The result, an RBE of 1.4-1.5 is similar to findings obtained by other methods, supporting the validity of this approach to derive an RBE with validity in a clinical context.

Animals↗

Dosimetric and microdosimetric study of contrast-enhanced radiotherapy with kilovolt x-rays.

Kilovolt x-rays are clearly suboptimal compared to MV photon beams for radiotherapy of deep-seated tumours because of the increased attenuation in tissue, causing a rapid dose fall-off. This picture could change drastically when tumours can be labelled with contrast medium, containing high atomic number elements. This causes a significant dose enhancement to the tumour by exploiting the high cross sections for the photo-electric effect for kV x-rays. In this work, we have investigated the dosimetric and microdosimetric characteristics of kV contrast-enhanced radiation therapy (CERT) for different photon energies, contrast-medium concentrations and types (I and Gd). Two idealized patient treatment plans (head and lung) for irradiation with CT-arc beams were calculated. It is shown that the dose enhancement in tumours can be highly significant (up to about sixfold for realistic 80-120 kVp x-ray spectra and an iodine concentration of 50 mg ml-1) but that dose homogeneity in the tumour depends on photon energy, contrast-medium concentration and type, and irradiation scheme. An attempt to optimize the irradiation scheme is discussed. The microdosimetric study of the dose mean lineal energy shows that radiation quality changes in the contrast-medium-labelled region compared to homogeneous tissue are fairly small and limited to 10%. It is concluded that kV-CERT is a promising radiotherapy technique, provided contrast medium can be delivered reliably to tumours.

Body Burden↗

Consistency test of the electron transport algorithm in the GEANT4 Monte Carlo code.

In this work, the condensed history algorithm in GEANT4 (version 4.6.2.p01) is examined. We performed simulations of an ionization chamber composed of water for 1.25 MeV incident photon beams under Fano conditions, and evaluated the consistency of the cavity response for several combinations of electron transport parameters. GEANT4 permits electrons to reach geometric boundaries in large steps, and underestimates lateral displacement near interfaces. Step size artefacts due to distortions in electron fluence and angular distributions reduce the cavity dose by up to 39%. Accurate cavity response can be achieved using severe user-imposed step size restrictions. We suggest that improvements in the electron transport algorithm in GEANT4 should address the handling of boundary crossing.

Algorithms↗

Experimental determination of electron source parameters for accurate Monte Carlo calculation of large field electron therapy.

Extensive work has been performed to validate Monte Carlo models for both photon and electron beams under standard conditions. However, for large field electron beam therapy, Monte Carlo simulations have not been able to provide good agreement when compared to the measured dose distributions. Since the accuracy of the calculation relies heavily on the geometry parameters of the linear accelerator and the characteristics of the incident electron beam, it is crucial to have a complete comprehension of these independent factors. In this work, the electron focal spot size for a CL21EX linac with various energies (6, 9, 12 and 16 MeV) was measured with a slit camera composed of alternating lead and paper sheets. For all the energies investigated, the electron focal spot is found to be elliptical and has a full width at half maximum (FWHM) ranging from 1.69 mm to 2.24 mm. A shift with respect to the crosshair was associated with each measured focal spot. In addition, we present an improved result for the large field in-air profile by utilizing a proposed divergent beam model in conjunction with the experimental focal spot dimension. This model can potentially provide a solution to the Monte Carlo validation of large field electron beam therapy.

Electrons↗

Development of a Monte Carlo model for the Brainlab microMLC.

Stereotactic radiosurgery with several static conformal beams shaped by a micro multileaf collimator (microMLC) is used to treat small irregularly shaped brain lesions. Our goal is to perform Monte Carlo calculations of dose distributions for certain treatment plans as a verification tool. A dedicated microMLC component module for the BEAMnrc code was developed as part of this project and was incorporated in a model of the Varian CL2300 linear accelerator 6 MV photon beam. As an initial validation of the code, the leaf geometry was visualized by tracing particles through the component module and recording their position each time a leaf boundary was crossed. The leaf dimensions were measured and the leaf material density and interleaf air gap were chosen to match the simulated leaf leakage profiles with film measurements in a solid water phantom. A comparison between Monte Carlo calculations and measurements (diode, radiographic film) was performed for square and irregularly shaped fields incident on flat and homogeneous water phantoms. Results show that Monte Carlo calculations agree with measured dose distributions to within 2% and/or 1 mm except for field size smaller than 1.2 cm diameter where agreement is within 5% due to uncertainties in measured output factors.

Algorithms↗

Monte Carlo based modulated electron beam treatment planning using a few-leaf electron collimator--feasibility study.

Energy modulated electron beam therapy with conventional clinical accelerators has lagged behind photon IMRT despite its potential to achieve highly conformal dose distributions in superficial targets. One of the reasons for this is the absence of an automated collimating device that allows for the flexible delivery of a series of variable field openings. Electron-specific multileaf collimators attached to the bottom of the applicator require the use of a large number of motors and suffer from being relatively bulky and impractical for head and neck sites. In this work, we investigate the treatment planning aspects of a proposed 'few-leaf' electron collimator (FLEC) that consists of four motor-driven trimmer bars at the end of the applicator. The device is designed to serve as an accessory to standard equipment and allows for the shaping of any irregular field by combination of rectangular fieldlets. Using a Monte Carlo model of the FLEC, dose distributions are optimized using a simulated annealing (SA) inverse planning algorithm based on a limited number of Monte Carlo pre-generated, realistic phantom-specific dose kernels and user-specified dose-volume constraints. Using a phantom setup with an artificial target enclosed by organs at risk (OAR) as well as using a realistic patient case, we demonstrate that highly conformal distributions can be generated. Estimates of delivery times are made and show that a full treatment fraction can be kept to 15 min or less.

Algorithms↗

Sensitivity study for CT image use in Monte Carlo treatment planning.

An important step in Monte Carlo treatment planning (MCTP), which is commonly performed uncritically, is segmentation of the patient CT data into a voxel phantom for dose calculation. In addition to assigning mass densities to voxels, as is done in conventional TP, this entails assigning media. Mis-assignment of media can potentially lead to significant dose errors in MCTP. In this work, a test phantom with exact-known composition was used to study CT segmentation errors and to quantify subsequent MCTP inaccuracies. For our test cases, we observed dose errors in some regions of up to 10% for 6 and 15 MV photons, more than 30% for an 18 MeV electron beam and more than 40% for 250 kVp photons. It is concluded that a careful CT calibration with a suitable phantom is essential. Generic calibrations and the use of commercial CT phantoms have to be critically assessed.

Calibration↗

Assigning nonelastic nuclear interaction cross sections to Hounsfield units for Monte Carlo treatment planning of proton beams.

In high energy clinical proton beams nonelastic nuclear interactions contribute substantially to the total dose. It is therefore of importance to know these contributions quantitatively and to be able to scale them correctly as a function of Hounsfield units obtained from CT data. In this work, the second of these issues has been addressed. The importance of taking material-dependent nonelastic nuclear interactions into account has been investigated for Monte Carlo calculations. A scaling curve for nonelastic nuclear interactions as a function of Hounsfield unit has been established and compared with similar data for the stopping powers. Monte Carlo simulations using McPTRAN.MEDIA and MCNPX have been performed in homogeneous media and in inhomogeneous slab geometries. The results show that for skeletal tissues and for adipose tissue, the tissue to water nonelastic cross section ratios differ up to 10% compared to the tissue to water stopping power ratios. This results in errors of the order of 2-3% when both contributions to the total dose are scaled in the same way (with stopping power ratios). Monte Carlo simulations in slab geometries with tissue materials for 200 MeV protons show similar effects, but when both contributions are scaled correctly the errors are not larger than 0.5% in the situations investigated here.

Adipose Tissue↗

Initial patient imaging with an optimised radiotherapy beam for portal imaging.

BACKGROUND AND PURPOSE: To investigate the feasibility and the advantages of a portal-imaging mode on a medical accelerator, consisting of a thin low-Z bremsstrahlung target and a thin Gd2O2S/film detector, for patient imaging. PATIENTS AND METHODS: The international code of practice for high-energy photon dosimetry was used to calibrate dosimetry instruments for the imaging beam produced by 4.75 MeV electrons hitting a 6mm thick aluminium target. Images of the head and neck of a humanoid phantom were taken with a mammography film system and the dose in the phantom was measured with TLDs calibrated for this beam. The first head and neck patient images are compared with conventional images (taken with the treatment beam on a film radiotherapy verification detector). Visibility of structures for six patients was evaluated. RESULTS: Images of the head and neck of a humanoid phantom, taken with both imaging systems showed that the contrast increased dramatically for the new system while the dose required to form an image was less than 10(-2)Gy. The patient images taken with the new and the conventional systems showed that air-tissue interfaces were better defined in the new system image. Anatomical structures, visible on both films, are clearer with the new system. Additionally, bony structures, such as vertebrae, were clearly visible only with the new system. The system under evaluation was significantly better for all features in lateral images and most features in anterior images. CONCLUSIONS: This pilot study of the new portal imaging system showed the image quality is significantly improved.

Head and Neck Neoplasms↗

Validation of Monte Carlo calculated surface doses for megavoltage photon beams.

Recent work has shown that there is significant uncertainty in measuring build-up doses in mega-voltage photon beams especially at high energies. In this present investigation we used a phantom-embedded extrapolation chamber (PEEC) made of Solid Water to validate Monte Carlo (MC)-calculated doses in the dose build-up region for 6 and 18 MV x-ray beams. The study showed that the percentage depth ionizations (PDIs) obtained from measurements are higher than the percentage depth doses (PDDs) obtained with Monte Carlo techniques. To validate the MC-calculated PDDs, the design of the PEEC was incorporated into the simulations. While the MC-calculated and measured PDIs in the dose build-up region agree with one another for the 6 MV beam, a non-negligible difference is observed for the 18 MV x-ray beam. A number of experiments and theoretical studies of various possible effects that could be the source of this discrepancy were performed. The contribution of contaminating neutrons and protons to the build-up dose region in the 18 MV x-ray beam is negligible. Moreover, the MC calculations using the XCOM photon cross-section database and the NIST bremsstrahlung differential cross section do not explain the discrepancy between the MC calculations and measurement in the dose build-up region for the 18 MV. A simple incorporation of triplet production events into the MC dose calculation increases the calculated doses in the build-up region but does not fully account for the discrepancy between measurement and calculations for the 18 MV x-ray beam.

Electrons↗

Accuracy of the photon and electron physics in GEANT4 for radiotherapy applications.

This work involves a validation of the photon and electron transport of the GEANT4 particle simulation toolkit for radiotherapy physics applications. We examine the cross sections and sampling algorithms of the three electromagnetic physics models in version 4.6.1 of the toolkit: Standard, Low-energy, and Penelope. The depth dose distributions in water for incident monoenergetic and clinical beams are compared to the EGSNRC results. In photon beam simulations, all three models agree with EGSNRC to within 2%, except for the buildup region. Larger deviations are found for incident electron beams, and the differences are affected by user-imposed electron step limitations. Particle distributions through thin layers of clinical target materials, and perturbation effects near high-Z and low-Z interfaces are also investigated. The electron step size artifacts observed in our studies indicate potential problems with the condensed history algorithm. A careful selection of physics processes and transport parameters is needed for optimum efficiency and accuracy.

Air↗

Energy modulated electron therapy using a few leaf electron collimator in combination with IMRT and 3D-CRT: Monte Carlo-based planning and dosimetric evaluation.

Energy modulated electron therapy (EMET) based on Monte Carlo dose calculation is a promising technique that enhances the treatment planning and delivery of superficially located tumors. This study investigated the application of EMET using a novel few-leaf electron collimator (FLEC) in head and neck and breast sites in comparison with three-dimensional conventional radiation therapy (3D-CRT) and intensity modulated radiation therapy (IMRT) techniques. Treatment planning was performed for two parotid cases and one breast case. Four plans were compared for each case: 3D-CRT, IMRT, 3D-CRT in conjunction with EMET (EMET-CRT), and IMRT in conjunction with EMET (EMET-IMRT), all of which were performed and calculated with Monte Carlo techniques. For all patients, dose volume histograms (DVHs) were obtained for all organs of interest and the DVHs were used as a means of comparing the plans. Homogeneity and conformity of dose distributions were calculated, as well as a sparing index that compares the effect of the low isodose lines. In addition, the whole-body dose equivalent (WBDE) was estimated for each plan. Adding EMET delivered with the FLEC to 3D-CRT improves sparing of normal tissues. For the two head and neck cases, the mean dose to the contralateral parotid and brain stem was reduced relative to IMRT by 43% and 84%, and by 57% and 71%, respectively. Improved normal tissue sparing was quantified as an increase in sparing index of 47% and 30% for the head and neck and the breast cases, respectively. Adding EMET to either 3D-CRT or IMRT results in preservation of target conformity and dose homogeneity. When adding EMET to the treatment plan, the WBDE was reduced by between 6% and 19% for 3D-CRT and by between 21% and 33% for IMRT, while WBDE for EMET-CRT was reduced by up to 72% when compared with IMRT. FLEC offers a practical means of delivering modulated electron therapy. Although adding EMET delivered using the FLEC results in perturbation of target conformity when compared to IMRT, it significantly improves normal tissue sparing while offering enhanced target conformity to the 3D-CRT planning. The addition of EMET systematically leads to a reduction in WBDE especially when compared with IMRT.

Breast Neoplasms↗

A small-body portable graphite calorimeter for dosimetry in low-energy clinical proton beams.

Calorimetry has been recommended and performed in proton beams for some time, but never has graphite calorimetry been used as a reference dosimeter in clinical proton beams. Furthermore, only a few calorimetry measurements have been reported in ocular proton beams. In this paper we describe the construction and performance of a small-body portable graphite calorimeter for clinical low-energy proton beams. Perturbation correction factors for the gap effect, volume averaging effect, heat transfer phenomena and impurity effect are calculated and applied in a comparison with ionization chamber dosimetry following IAEA TRS-398. The ratio of absorbed dose to water obtained from the calorimeter measurements and from the ionization measurements varied between 0.983 and 1.019, depending on the beam type and the ionization chamber calibration modality. Standard uncertainties on these values varied between 1.9% and 2.5% including a substantial contribution from the kQ values in IAEA TRS-398. The (Wair/e)p values inferred from these measurements varied between 33.6 J C(-1) and 34.9 J C(-1) with similar standard uncertainties. A number of improvements for the small-body portable graphite calorimeter and the experimental set-up are suggested for potential reduction of the uncertainties.

Calibration↗

Backscatter and dose perturbations for low- to medium-energy electron point sources at the interface between materials with different atomic numbers.

Electron backscatter at interfaces between dissimilar media can affect dosimetry and should be taken into consideration in radiotherapy and in radiobiology experiments. Backscatter dose perturbations depend upon factors such as electron energy, medium atomic number (Z), and distance from the interface. This study quantifies the backscatter dose factor (BSDF) for electron point sources of energy between 0.1 to 3 MeV in water at the interface with scattering materials ranging in Z from (13)Al to (79)Au. A Monte Carlo code that performs dose calculations for monoenergetic and continuous-spectrum electron sources was developed using EGSnrc transport routines. The BSDF was quantified in a parallel layers geometry (BSDF(1D)) and three-dimensional voxel geometry (BSDF(3D)). The BSDF(1D) near the interface increased up to 52% with decreasing energy from 3 to 0.1 MeV and increasing Z from 13 to 79. The analysis of the BSDF(3D) showed a significant dependence of the scattered electron angular distribution on Z and energy, with a decrease in isotropy going from high to low Z. This effect proves the importance of considering the correct geometry when quantifying the BSDF for electron sources, especially when the dimensions of the relevant dose-collecting volume are comparable with the CSDA range of the source.

Electrons↗