PubMed Health⌕ Search

Biomedical subjects

Frank Weichert

Publications and source records attributed to Frank Weichert.

5 recordsLinked to original sources

Evaluation of two 3D virtual computer reconstructions for comparison of cleft lip and palate to normal fetal microanatomy.

Cleft lip and palate reconstructive surgery requires thorough knowledge of normal and pathological labial, palatal, and velopharyngeal anatomy. This study compared two software algorithms and their 3D virtual anatomical reconstruction because exact 3D micromorphological reconstruction may improve learning, reveal spatial relationships, and provide data for mathematical modeling. Transverse and frontal serial sections of the midface of 18 fetal specimens (11th to 32nd gestational week) were used for two manual segmentation approaches. The first manual segmentation approach used bitmap images and either Windows-based or Mac-based SURFdriver commercial software that allowed manual contour matching, surface generation with average slice thickness, 3D triangulation, and real-time interactive virtual 3D reconstruction viewing. The second manual segmentation approach used tagged image format and platform-independent prototypical SeViSe software developed by one of the authors (F.W.). Distended or compressed structures were dynamically transformed. Registration was automatic but allowed manual correction, such as individual section thickness, surface generation, and interactive virtual 3D real-time viewing. SURFdriver permitted intuitive segmentation, easy manual offset correction, and the reconstruction showed complex spatial relationships in real time. However, frequent software crashes and erroneous landmarks appearing "out of the blue," requiring manual correction, were tedious. Individual section thickness, defined smoothing, and unlimited structure number could not be integrated. The reconstruction remained underdimensioned and not sufficiently accurate for this study's reconstruction problem. SeViSe permitted unlimited structure number, late addition of extra sections, and quantified smoothing and individual slice thickness; however, SeViSe required more elaborate work-up compared to SURFdriver, yet detailed and exact 3D reconstructions were created.

Cleft Lip↗

Tissue-plastinated vs. celloidin-embedded large serial sections in video, analog and digital photographic on-screen reproduction: a preliminary step to exact virtual 3D modelling, exemplified in the normal midface and cleft-lip and palate.

This study analyses tissue-plastinated vs. celloidin-embedded large serial sections, their inherent artefacts and aptitude with common video, analog or digital photographic on-screen reproduction. Subsequent virtual 3D microanatomical reconstruction will increase our knowledge of normal and pathological microanatomy for cleft-lip-palate (clp) reconstructive surgery. Of 18 fetal (six clp, 12 control) specimens, six randomized specimens (two clp) were BiodurE12-plastinated, sawn, burnished 90 microm thick transversely (five) or frontally (one), stained with azureII/methylene blue, and counterstained with basic-fuchsin (TP-AMF). Twelve remaining specimens (four clp) were celloidin-embedded, microtome-sectioned 75 microm thick transversely (ten) or frontally (two), and stained with haematoxylin-eosin (CE-HE). Computed-planimetry gauged artefacts, structure differentiation was compared with light microscopy on video, analog and digital photography. Total artefact was 0.9% (TP-AMF) and 2.1% (CE-HE); TP-AMF showed higher colour contrast, gamut and luminance, and CE-HE more red contrast, saturation and hue (P < 0.4). All (100%) structures of interest were light microscopically discerned, 83% on video, 76% on analog photography and 98% in digital photography. Computed image analysis assessed the greatest colour contrast, gamut, luminance and saturation on video; the most detailed, colour-balanced and sharpest images were obtained with digital photography (P < 0.02). TP-AMF retained spatial oversight, covered the entire area of interest and should be combined in different specimens with CE-HE which enables more refined muscle fibre reproduction. Digital photography is preferred for on-screen analysis.

Artifacts↗

A 3D computer graphics approach to brachytherapy planning.

Intravascular brachytherapy (IVB) can significantly reduce the risk of restenosis after interventional treatment of stenotic arteries, if planned and applied correctly. In order to facilitate computer-based IVB planning, a three-dimensional reconstruction of the stenotic artery based on intravascular ultrasound (IVUS) sequences is desirable. For this purpose, the frames of the IVUS sequence are properly aligned in space, possible gaps inbetween the IVUS frames are filled by interpolation with radial basis functions known from scattered data interpolation. The alignment procedure uses additional information which is obtained from biplane X-ray angiography performed simultaneously during the capturing of the IVUS sequence. After IVUS images and biplane angiography data are acquired from the patient, the vessel-wall borders and the IVUS catheter are detected by an active contour algorithm. Next, the twist (relative orientation) between adjacent IVUS frames is determined by a sequential triangulation method. The absolute orientation of each frame is established by a stochastic analysis based on anatomical landmarks. Finally, the reconstructed 3D vessel model is visualized by methods of combined volume and polygon rendering. The reconstruction is then used for the computation of the radiation-distribution within the tissue, emitted from a beta-radiation source. All these steps are performed during the percutaneous intervention.

Algorithms↗

Virtual 3D IVUS vessel model for intravascular brachytherapy planning. I. 3D segmentation, reconstruction, and visualization of coronary artery architecture and orientation.

Intravascular brachytherapy (IVB) can significantly reduce the risk of restenosis after interventional treatment of stenotic arteries, if planned and applied correctly. To facilitate computer-based IVB planning, a three-dimensional vessel model has been derived from information on coronary artery segments acquired by intravascular ultrasound (IVUS) and biplane angiography. Part I describes the approach of model construction and presents possibilities of visualization. The vessel model is represented by a voxel volume. Polygonal information about the vessel wall structure is derived by segmentation from a sequence of IVUS images automatically acquired ECG gated during pull back of the IVUS transducer. To detect horizontal, vertical, and radial contours, modified Canny-Edge and Shen-Castan filters are applied on Cartesian and polar coordinate representations of the IVUS tomograms as edge detectors. The spatial course of the vessel wall layers is traced in reconstructed longitudinal IVUS scans. By resampling the sequence of IVUS frames the voxel volume is obtained. For this purpose the frames are properly located in space and augmented with additional intermediate frames generated by interpolation. Their spatial location and orientation is derived from biplane X-ray angiography which is performed simultaneously. For resampling, two approaches are proposed: insertion of the vertices of the rectangular goal grid into the cells of a deformed hexahedral mesh derived from the IVUS sequence, and insertion of the vertices of the hexahedral mesh into the cells of the rectangular grid. Finally, the vessel model is visualized by methods of combined volume and polygon rendering. The segmentation process is verified as being in good agreement with results obtained by manual contour tracing with a commercial system. Our approach of construction of the vessel model has been implemented into an interactive software system, 3D IVUS-View, serving as the basis of a future system for intracoronary brachytherapy treatment planning being currently under development (Part II).

Algorithms↗

Simulating soft data to make soft data applicable to simulation.

BACKGROUND: Biomedical processes are often influenced by measures considered "non-crisp", "soft" or "subjective". Despite the growing awareness of the importance of such measures, they are rarely considered in biomedical simulation. This study introduces an input generator for soft data (input generator SD) that makes soft data applicable to simulation. MATERIALS AND METHODS: Machine learning approaches and standard regression techniques were applied to simulate odour intensity ratings. RESULTS: The performance of all the applied methods was satisfactory and the results can be used to modify systems biological mathematical models. CONCLUSION: Soft data should no longer be discounted in systems biological simulations. Exemplarily, it can be demonstrated that the input generator SD produces results that are similar to those that the simulated system can generate. Machine learning and/or appropriate conventional mathematical approaches may be applied to simulate noncrisp processes that can be used to modify mathematical models of any granularity.

Adult↗