Publications and source records attributed to Franz Schmitt.

6 recordsLinked to original sources

Bright and black blood imaging of the carotid bifurcation at 3.0T.

PURPOSE: The aim of this study was to evaluate our preliminary experience at 3.0 T with imaging of the carotid bifurcation in healthy and atherosclerotic subjects. Application at 3.0 T is motivated by the signal-to-noise gain for improving spatial resolution and reducing signal averaging requirements. MATERIALS AND METHODS: We utilized a dual phased array coil and applied 2D, 3D time of flight (TOF) and turbo spin echo (TSE) sequences with comparison of two lumen signal suppression methods for black blood (BB) TSE imaging including double inversion preparation (DIR) and spatial presaturation pulses. The signal-to-noise ratios (SNR) of healthy carotid vessel walls were compared in 2D and 3D BB TSE acquisitions. The bright and black blood multi-contrast exam was demonstrated for a complex carotid plaque. RESULTS: Contrast-to-noise (CNR) greater than 150 was achieved between the lumen and suppressed background for 3D TOF. For BB, both methods provided sufficient lumen signal suppression but slight residual flow artifacts remained at the bifurcation level. As expected 3D TSE images had higher SNR compared to 2D, but increased motion sensitivity is a significant issue for 3D at high field. For multi-contrast imaging of atherosclerotic plaque, fibrous, calcified and lipid components were resolved. The CNR ratio of fibrous (bright on PDW, T2W) and calcified (dark in T1W, T2W, PDW) plaque components was maximal in the T2W images. The 3D TOF angiogram indicating a 40% stenosis was complemented by 3D multi-planar reformat of BB images that displayed plaque extent. Detection of intimal thickening, the earliest change associated with atherosclerotic progression was observed in BB PDW images at 3.0 T. CONCLUSIONS: High SNR and CNR images have been demonstrated for the healthy and diseased carotid. Improvements in RF coils along with pulse sequence optimization, and evaluation of endogenous and exogenous contrast mechanisms will further enhance carotid imaging at 3.0T.

Adult↗

Parallel RF transmission with eight channels at 3 Tesla.

Spatially selective RF waveforms were designed and demonstrated for parallel excitation with a dedicated eight-coil transmit array on a modified 3T human MRI scanner. Measured excitation profiles of individual coils in the array were used in a low-flip-angle pulse design to achieve desired spatial target profiles with two- (2D) and three-dimensional (3D) k-space excitation with simultaneous transmission of RF on eight channels. The 2D pulse excited a high-resolution spatial pattern in-plane, while the 3D trajectory produced high-quality slice selection with a uniform in-plane excitation despite the highly nonuniform individual spatial profiles of the coil array. The multichannel parallel RF excitation was used to accelerate the 2D excitation by factors of 2-8, and experimental results were in excellent agreement with simulations based on the measured coil maps. Parallel RF transmission may become critical for robust and routine human studies at very high field strengths where B(1) inhomogeneity is commonly severe.

Equipment Design↗

Reliability in multi-site structural MRI studies: effects of gradient non-linearity correction on phantom and human data.

Longitudinal and multi-site clinical studies create the imperative to characterize and correct technological sources of variance that limit image reproducibility in high-resolution structural MRI studies, thus facilitating precise, quantitative, platform-independent, multi-site evaluation. In this work, we investigated the effects that imaging gradient non-linearity have on reproducibility of multi-site human MRI. We applied an image distortion correction method based on spherical harmonics description of the gradients and verified the accuracy of the method using phantom data. The correction method was then applied to the brain image data from a group of subjects scanned twice at multiple sites having different 1.5 T platforms. Within-site and across-site variability of the image data was assessed by evaluating voxel-based image intensity reproducibility. The image intensity reproducibility of the human brain data was significantly improved with distortion correction, suggesting that this method may offer improved reproducibility in morphometry studies. We provide the source code for the gradient distortion algorithm together with the phantom data.

Calibration↗

On-line automatic slice positioning for brain MR imaging.

In clinical brain MR imaging protocols, the technician collects a quick localizer and manually positions the subsequent scans using the localizer as a guide. We present a method for automatic slice positioning using a rapidly acquired 3D localizer. The localizer is automatically aligned to a statistical atlas representing 40 healthy subjects. The atlas contains the probability of a given tissue type occurring at a given location in atlas space and the conditional probability distribution of the multi-spectral MRI intensity values for a given tissue class. Accurate rigid alignment of each subject to an atlas ensures that all patients' scans are acquired in a consistent manner. A further benefit is that slices are positioned consistently over time, so that scans of patients returning for follow-up imaging can be compared side-by-side to accurately monitor the progression of illness. The procedure also helps ensure that left/right asymmetries reflect true anatomy rather than being the result of oblique slice positioning relative to the underlying anatomy. The use of an atlas-based procedure eliminates the need to refer to a database of previously scanned images of the same patient and ensures corresponding alignment across scanners and sites, without requiring fiducial markers. Since the registration method is probabilistic, the registration error tends to increase smoothly in the presence of increasing noise and unusual anatomy or pathology rather than failing catastrophically. Translations and rotations relative to the atlas can be set so that planning can be done in anatomical space, rather than scanner coordinates, and stored as part of the protocol allowing standardization of slice orientations.

Algorithms↗

Comparison of cardiac MRI on 1.5 and 3.0 Tesla clinical whole body systems.

RATIONALE AND OBJECTIVES: A cardiac imaging pilot study was performed on 1.5 and 3.0 Tesla (T) whole body magnetic resonance units equipped with identical gradient sets and geometrically equivalent body coils. The goals were to compare the signal-to-noise (SNR) and contrast-to-noise (CNR) ratios on matched studies conducted at both field strengths and demonstrate the potential for functional and morphologic cardiac evaluation at 3.0 T. METHODS: Short axis cine true fast imaging with steady precession (True FISP) was compared at 1.5 and 3.0 T using the body coil in transmit-receive mode and transmit-only with single loop and phased array receiver coils. SNR of the myocardium and CNR of the ventricular blood and myocardium were calculated from a quantitative region of interest analysis of these data. Additionally at 3.0 T, long axis and 4-chamber cine as well as "dark blood" imaging are demonstrated with sequence and parameter settings comparable to current state of the art for cardiac evaluation at 1.5 T. RESULTS: The 3.0 T data consistently demonstrates increases in SNR when all imaging conditions are closely matched but the increase has a large variability ranging from 20 to 85% depending on the radiofrequency coil configuration. Ventricular blood-myocardium CNR greater than 30 is obtained at 3.0 T, which is comparable to an optimized 1.5 T acquisition despite the specific absorption rate limitation of flip angle to nearly one half the value. The increased SNR at 3.0 T improves detection of fine anatomic detail, such as the chordae tendineae and mitral valve structure. CONCLUSIONS: Increased specific absorption rate can be a limiting fact; however, we have demonstrated that 3.0 T cardiac imaging shows gains in SNR while maintaining the CNR. The SNR gain is advantageous, and phased array coil technology is key for improving cardiac magnetic resonance imaging at 3.0 T.

Aged↗

Gradient system providing continuously variable field characteristics.

Peripheral nerve stimulation limits the use of whole-body gradient systems capable of slew rates > 80 T/m/s and gradient strengths > 25 mT/m. The stimulation threshold depends mainly on the amplitude of the induced electric field in the patient's body, and thus can be influenced by changing the total magnetic flux of the gradient coil. A gradient system was built which allows continuous variation of the field characteristics in order to permit the use of full gradient performance without stimulation (slew rate 190-210 T/m/s, G(max) 32-40 mT/m). The system consists of a modular six-channel gradient coil designed with a modified target field method, two three-channel amplifiers, and a six-channel gradient controller. It is demonstrated that two coils on one gradient axis can be driven by two amplifiers in parallel, without significant changes in image quality. Scaling of the field properties and stimulation threshold according to the current polarity and ratio of both coil sets was verified in both phantom and volunteer studies.

Equipment Design↗