Visual and automatic grading of coronary artery stenoses with 64-slice CT angiography in reference to invasive angiography.

The aim of this study was to assess the performance of a software tool for quantitative coronary artery analysis of computed tomography coronary angiography (CT-QCA) in comparison with invasive coronary angiography with quantitative analysis (CAG-QCA) as standard of reference. Two radiologists reviewed the CT angiography data sets (Siemens Sensation 64) of 25 patients, grading coronary artery stenoses visually and with a software tool (Circulation, Siemens). Twenty-three data sets with sufficient image quality were included in the final analysis. CAG revealed a total of 30 wall irregularities and 28 stenoses, of which 17 were graded as moderate and nine as hemodynamically significant. CT-QCA showed a better agreement to CAG-QCA, with a systematic overestimation of the degree of stenosis of 6.1% and limits of agreement of +36.1% and -23.9; the correlation coefficient was 0.82 (p < 0.0001). Using CT-QCA, sensitivity, specificity, and positive and negative predictive value were 89%, 100%, 89%, and 100%, respectively, for significant area stenoses greater than 75%. The positive predictive value for the visual assessment amounted to 53%. Interobserver variability between CT-QCA and visual assessment showed a kappa value of 0.72. In conclusion, software-supported CT-QCA makes it possible to quantify significant coronary artery stenoses automatically, with good agreement to CAG-QCA.

Contrast Media↗

Sixty-four slice spiral CT angiography does not predict the functional relevance of coronary artery stenoses in patients with stable angina.

PURPOSE: The aim of this study was to evaluate spiral multidetector computed tomography (MDCT) angiography using 64-slice technique in the detection of functionally relevant coronary artery stenoses (CAS). METHODS: Thirty-eight patients (62+/-11 years, 28 men) with stable angina (26 with suspected and 12 with known coronary artery disease) were investigated using 64-slice MDCT angiography and gated myocardial perfusion SPECT (gated SPECT); a subgroup of 30 patients had additional invasive coronary angiography (ICA). Stenoses with luminal narrowing of >or=50% were defined as "significant" in MDCT angiography and ICA. MDCT angiography was compared with gated SPECT and the combination of gated SPECT plus ICA with respect to the detection of functionally relevant CAS. RESULTS: The sensitivity, specificity and negative and positive predictive values of MDCT angiography in detecting reversible perfusion defects on gated SPECT were 63%, 80%, 94% and 32%, respectively, in vessel-based analysis and 71%, 62%, 72% and 60%, respectively, in patient-based analysis. If only reversible perfusion defects on gated SPECT with CAS >or=50% on ICA were considered, the sensitivity, specificity and negative and positive predictive values were, respectively, 85%, 79%, 98% and 33% for vessel-based analysis and 85%, 59%, 83% and 61% for patient-based analysis. CONCLUSION: Sixty-four slice MDCT angiography failed to predict the functional relevance of CAS, but had a high negative predictive value in the exclusion of functionally relevant CAS in symptomatic patients.

Angina Pectoris↗

Dual-source CT cardiac imaging: initial experience.

The relation of heart rate and image quality in the depiction of coronary arteries, heart valves and myocardium was assessed on a dual-source computed tomography system (DSCT). Coronary CT angiography was performed on a DSCT (Somatom Definition, Siemens) with high concentration contrast media (Iopromide, Ultravist 370, Schering) in 24 patients with heart rates between 44 and 92 beats per minute. Images were reconstructed over the whole cardiac cycle in 10% steps. Two readers independently assessed the image quality with regard to the diagnostic evaluation of right and left coronary artery, heart valves and left ventricular myocardium for the assessment of vessel wall changes, coronary stenoses, valve morphology and function and ventricular function on a three point grading scale. The image quality ratings at the optimal reconstruction interval were 1.24+/-0.42 for the right and 1.09+/-0.27 for the left coronary artery. A reconstruction of diagnostic systolic and diastolic images is possible for a wide range of heart rates, allowing also a functional evaluation of valves and myocardium. Dual-source CT offers very robust diagnostic image quality in a wide range of heart rates. The high temporal resolution now also makes a functional evaluation of the heart valves and myocardium possible.

Algorithms↗

Accuracy of 64-slice computed tomography to classify and quantify plaque volumes in the proximal coronary system: a comparative study using intravascular ultrasound.

OBJECTIVES: We evaluated the accuracy of a new 64-slice computed tomography (CT) scanner, compared with intravascular ultrasound, to visualize atherosclerosis in the proximal coronary system. BACKGROUND: Noninvasive determination of plaque composition and plaque burden may be important to improve risk stratification. METHODS: In 20 patients, a 64-slice CT scan (Sensation 64, Siemens Medical Solutions, Forchheim, Germany) and an intravascular ultrasound investigation of vessels without stenosis >50% was performed. Diagnostic image quality with 64-slice CT was obtained in 36 vessels in 19 patients. RESULTS: In these vessels, which were divided in 3-mm sections, 64-slice CT enabled a correct detection of plaque in 54 of 65 (83%) sections containing noncalcified plaques, 50 of 53 (94%) sections containing mixed plaques, and 41 of 43 (95%) sections containing calcified plaques. In 192 of 204 (94%) sections, atherosclerotic lesions were excluded correctly. In addition, 64-slice CT enabled the visualization of 7 of 10 (70%) sections revealing a lipid pool and could identify a spotty calcification pattern in 27 of 30 (90%) sections. The correlation coefficient to determine plaque volumes per vessel was r2 = 0.69 (p < 0.001) with an underestimation of mixed and noncalcified plaque volumes (p < 0.03) and a trend to overestimate calcified plaque volumes by 64-slice CT. The interobserver variability to determine plaque volumes was 37%. Interobserver agreement to identify atherosclerotic sections was good (Cohen's kappa coefficient = 0.75). CONCLUSIONS: We conclude that 64-slice CT reveals encouraging results to noninvasively detect different types of coronary plaques located in the proximal coronary system. The ability to determine plaque burden currently is hampered by mainly an insufficient reproducibility.

Coronary Angiography↗

Assessment of coronary artery stent patency and restenosis using 64-slice computed tomography.

RATIONALE AND OBJECTIVES: Restenosis remains a major limitation of coronary catheter-based stent placement. Therefore, a reliable noninvasive diagnostic method for the evaluation of stented coronary arteries would be highly desirable. Our aim was to evaluate the diagnostic accuracy of high-resolution 64-slice computed tomography (64SCT) in a pilot study for the assessment of the lumen of coronary artery stents. MATERIALS AND METHODS: Twenty-five patients underwent 64SCT of the coronary arteries and quantitative x-ray coronary angiography (QCA) after coronary artery stent placement. 64SCT coronary angiography was performed with the following parameters: spatial resolution = 0.4 x 0.4 x 0.4 mm; temporal resolution = 83-165 milliseconds; contrast agent = 80 mL at a flow rate of 5 mL/second; retrospective electrocardiogram gating. The 64SCT scans were evaluated for image quality and for the presence of significant in-stent and peri-stent (proximal and distal) stenoses. Determinations were made of the sensitivity, specificity, diagnostic accuracy, and positive and negative predictive values (PPV and NPV) of 64SCT for the detection or exclusion of stenoses. RESULTS: A total of 46 stents were evaluated, of which 45 (98%) were of diagnostic image quality. Significant in-stent restenosis or occlusion was detected on QCA in 8/45 cases (>/=50% stenosis = 6; occlusion = 2). The sensitivity, specificity, accuracy, PPV, and NPV of 64SCT for the detection of significant in-stent disease was 75%, 92%, 89%, 67%, and 94%, respectively. Both occluded coronary artery stents were correctly identified. The sensitivity, specificity, and accuracy values of 64SCT for the detection of significant proximal peri-stent stenoses were 75%, 95%, and 93%, respectively, whereas the values for detection of significant distal peri-stent stenoses were 67%, 85%, and 84%, respectively. CONCLUSION: The high spatial and temporal resolution of 64SCT may permit improved assessment of stent occlusion and peri-stent disease, although detection of in-stent stenosis remains difficult.

Adult↗

Image quality, motion artifacts, and reconstruction timing of 64-slice coronary computed tomography angiography with 0.33-second rotation speed.

OBJECTIVES: We sought to evaluate the impact of patients' heart rate (HR) on coronary CTA image quality (IQ) and motion artifacts using a 64-slice scanner with 0.33/360 degrees rotation. MATERIALS AND METHODS: Coronary CTA data sets of 32 patients (HR 65 bpm to 75 bpm, n = 7) examined on a 64-slice scanner (Sensation 64, Siemens Medical Solutions, Forchheim, Germany) with 0.33s/360 degrees gantry rotation speed were analyzed. All patients had suspicion of coronary artery disease. Data acquisition was performed using 64 x 0.6-mm collimation, and contrast enhancement was provided by injection of 80 mL of iopromide (5 mL/s + NaCl). Images were reconstructed throughout the RR interval using half-scan and dual-segment reconstruction. IQ was rated by 2 observers using a 3-point scale from excellent (1) to nondiagnostic (3) for coronary segments. Quality was correlated to the HR, time point of optimal IQ analyzed, and the benefit of dual-segment reconstruction evaluated. RESULTS: Overall mean IQ was 1.31 +/- 0.32 for all HR, with IQ being 1.08 +/- 0.12 for HR 65 bpm 75 bpm (P = 0.0003). Dual-segment reconstruction did not significantly improve IQ in any HR group (P = NS). Mean IQ was significantly better for LAD than for RCA (P < 0.0001) and LCX (P < 0.01). A total of 3.5% (11/318) of coronary artery segments were rated nondiagnostic by at least one reader based on motion artifacts. Although in HR < 65 bpm, the best IQ was predominately in diastole (93%), in HR > 75 bpm, the best IQ shifted to systole in most cases (86%). CONCLUSIONS: Temporal resolution at 0.33-second rotation allows for diagnostic IQ within a wide range of HR using half-scan reconstruction. With increasing HR the time point of best IQ shifts from mid-diastole to systole.

Adult↗

Contrast bolus optimization for cardiac 16-slice computed tomography: comparison of contrast medium formulations containing 300 and 400 milligrams of iodine per milliliter.

OBJECTIVES: The aims of our study were to compare contrast injection protocols with contrast media containing 300 and 400 mg iodine per milliliter for optimal contrast enhancement in cardiac multidector row computed tomography (CT) and to evaluate the correlation of test bolus curve parameters with the final contrast density of the main bolus. MATERIALS AND METHODS: Sixty patients with known or suspected coronary artery disease were included in a prospective double-blind study. Patients were randomized to 2 groups. Group 1 received 83 mL of a contrast medium (CM) containing 300 mg of iodine (Iomeron 300, Bracco Imaging SpA, Milan, Italy) at a flow rate of 3.3 mL/s, whereas group 2 received 63 mL of the same agent containing 400 mg of iodine (Iomeron 400) at a flow rate of 2.5 mL/s. The test bolus volumes were 20 mL and 15 mL, respectively. Imaging was performed using a 16-slice CT system (16DCT; Somatom Sensation 16, Siemens Medical Solutions, Forchheim, Germany). Contrast densities (Hounsfield Units [HU]) were determined in the cardiac chambers and in the main coronary arteries. The peak density and area under the curve of the test bolus were calculated for each patient. RESULTS: The mean contrast densities of the coronary arteries were 259.1 +/- 46.7 HU for group 1 and 251.6 +/- 51.0 HU, for group 2. No noteworthy differences between groups were noted for density measurements in the cardiac chambers or for the ratio of right-to-left ventricle density. Whereas a positive correlation was noted for both groups between the area under the curve of the test bolus and the mean density of the main bolus, a positive correlation between peak density of the test bolus and mean density of the main bolus was noted only for group 1. CONCLUSION: Equivalent homogenous enhancement of the ventricular cavities and coronary arteries to that obtained using a CM with standard iodine concentration (Iomeron 300) can be achieved with lower overall volumes of administered CM and reduced injection flow rates when a CM with high iodine concentration (Iomeron 400) is used.

Adult↗

Clinical value of MDCT in the diagnosis of coronary artery disease in patients with a low pretest likelihood of significant disease.

OBJECTIVE: The aim of this study was to evaluate the clinical value of MDCT in the diagnosis of coronary artery disease in a population having a low pretest likelihood of significant disease. SUBJECTS AND METHODS: Sixty-four patients with suspected coronary artery disease and a low pretest likelihood of significant disease according to the criteria of the American Heart Association underwent both MDCT of the heart and quantitative conventional coronary angiography (QCA). MDCT examinations were performed on a 16-MDCT scanner. CT data sets were evaluated on a per-patient basis and a per-segment basis and were classified as indicating no disease, nonsignificant disease (stenoses </= 50%), or significant disease (stenoses > 50%). Sensitivity, specificity, negative predictive value (NPV), and positive predictive value (PPV) of 16-MDCT in the detection or exclusion of significant and nonsignificant coronary artery disease were evaluated on both per-patient and per-segment bases. RESULTS: Regarding the success rate of 16-MDCT, 94% (60/64) of patients and 92% (388/420) of vessel segments were of sufficient quality for diagnosis. In the remaining 60 patients evaluated, QCA revealed significant coronary artery disease, nonsignificant disease, and no disease in 8.3% (5/60), 75.0% (45/60), and 16.7% (10/60) of cases, respectively, on a per-patient basis, and in 1.3% (5/388), 23.2% (90/388), and 75.5% (293/388) of cases, respectively, on a per-segment basis. The sensitivity, specificity, NPV, and PPV of 16-MDCT for the detection of significant coronary artery disease were 80.0%, 94.5%, 98.1%, and 57.1%, respectively, on a per-patient basis, and 80.0%, 99.2%, 99.7%, and 57.1% on a per-segment basis. CONCLUSION: In a population having a low pretest likelihood of significant coronary artery disease, 16-MDCT shows a moderate to high sensitivity and high NPV for the detection or exclusion of significant disease, but has a somewhat reduced PPV compared with QCA.

Adult↗

Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography: a comparative study with quantitative coronary angiography and intravascular ultrasound.

OBJECTIVES: The aim of the present study was to determine the diagnostic accuracy of 64-slice computed tomography (CT) to identify and quantify atherosclerotic coronary lesions in comparison with catheter-based angiography and intravascular ultrasound (IVUS). BACKGROUND: Currently, the ability of multislice CT to quantify the degree of coronary artery stenosis and dimensions of coronary plaques has not been evaluated. METHODS: We included 59 patients scheduled for coronary angiography due to stable angina pectoris. A contrast-enhanced 64-slice CT (Senation 64, Siemens Medical Solutions, Forchheim, Germany) was performed before the invasive angiogram. In a subset of 18 patients, IVUS of 32 vessels was part of the catheterization procedure. RESULTS: In 55 of 59 patients, 64-slice CT enabled the visualization of the entire coronary tree with diagnostic image quality (American Heart Association 15-segment model). The overall correlation between the degree of stenosis detected by quantitative coronary angiography compared with 64-slice CT was r = 0.54. Sensitivity for the detection of stenosis <50%, stenosis >50%, and stenosis >75% was 79%, 73%, and 80%, respectively, and specificity was 97%. In comparison with IVUS, 46 of 55 (84%) lesions were identified correctly. The mean plaque areas and the percentage of vessel obstruction measured by IVUS and 64-slice CT were 8.1 mm2 versus 7.3 mm2 (p < 0.03, r = 0.73) and 50.4% versus 41.1% (p < 0.001, r = 0.61), respectively. CONCLUSIONS: Contrast-enhanced 64-slice CT is a clinically robust modality that allows the identification of proximal coronary lesions with excellent accuracy. Measurements of plaque and lumen areas derived by CT correlated well with IVUS. A major limitation is the insufficient ability of CT to exactly quantify the degree of stenosis.

Aged↗

Accuracy of multidetector spiral computed tomography in identifying and differentiating the composition of coronary atherosclerotic plaques: a comparative study with intracoronary ultrasound.

OBJECTIVES: We evaluated the accuracy of contrast-enhanced multidetector spiral computed tomography (MDCT) for the noninvasive detection and classification of coronary plaques and compared it with intracoronary ultrasound (ICUS). BACKGROUND: Noninvasive determination of plaque composition and plaque burden may be important to improve risk stratification and to monitor progression of coronary atherosclerosis. METHODS: We included 46 consecutive patients with a distinctive risk profile, who were investigated by ICUS (Goldvision, 20 MHz, Jomed Inc., Rancho Cordova, California). Due to the inability to slow the heart rate below 65 beats/min (n = 7) and due to renal insufficiency (n = 2), nine of 46 consecutive patients could not be studied by MDCT (Sensation 16, Siemens, Forchheim, Germany). RESULTS: In the remaining 37 patients, 68 vessels were investigated by ICUS, and 58 of these vessels were visualized by MDCT with image quality sufficient for analysis. In these vessels that were divided in 3-mm sections, MDCT correctly classified 62 of 80 (78%) sections containing hypoechoic plaque areas, 87 of 112 (78%) sections containing hyperechoic plaque areas, and 150 of 158 (95%) sections containing calcified plaque tissue. In 484 of 525 (92%) sections, atherosclerotic lesions were correctly excluded. The MDCT-derived density measurements within coronary lesions revealed significantly different values for hypoechoic (49 HU [Hounsfield Units] +/- 22), hyperechoic (91 HU +/- 22), and calcified plaques (391 HU +/- 156, p < 0.02). CONCLUSIONS: This study demonstrates that, in the case of diagnostic image quality, contrast-enhanced MDCT permits an accurate identification of coronary plaques and that computed tomography density values measured within plaques reflect echogenity and plaque composition.

Aged↗