PubMed Health⌕ Search

Biomedical subjects

Franz-Günter Sander

Publications and source records attributed to Franz-Günter Sander.

7 recordsLinked to original sources

Development of a model for the simulation of orthodontic load on lower first premolars using the finite element method.

AIM: This study was undertaken to calculate the stress in the tooth, surrounding periodontal ligament, and in the alveolar bone when a lower first premolar is subjected to intrusion or torque movement using a constant moment. Root resorptions occur even when very low forces and moments are used in orthodontic therapy. It is therefore of great interest to determine and measure the stress that occurs under particular treatment conditions in the periodontal ligament. MATERIAL AND METHODS: In this study, three finite element calculations were carried out with a realistic 3D model developed by CT data that consisted of a lower premolar, the surrounding periodontal ligament and alveolar bone. In close reference to the in-vivo experiments carried out by Faltin et al. in São Paulo, Brazil, our model was subjected to an intrusive force on the premolar of 0.5 N and a lingual root torque of 3 Nmm. RESULTS: The three main stress directions and hydrostatic stress were quantified in all the surrounding tissues, revealing that the hydrostatic stress profile in the periodontal ligament correlated closely with resorption findings in Faltin et al.'s patients. Resorption occurred in the experimental study in Brazil when the hydrostatic stress exceeded capillary blood pressure in the periodontal ligament. CONCLUSION: We maintain that hydrostatic stress represents a suitable indicator for potential root resorptions caused by higher forces and moments, making it a helpful tool in the development of new orthodontic appliances. We must of course mention that there are many factors other than forces that are responsible for resorptions. But at the moment, only the force can be influenced by the orthodontist.

Bicuspid↗

Efficiency of a pendulum appliance for molar distalization related to second and third molar eruption stage.

A modified pendulum appliance, including a distal screw and special preactivated pendulum springs (built-in straightening activation and toe-in bending), was used for bilateral maxillary molar distalization in 36 adolescent patients in various stages of the molar dentition. The patients were divided into 3 groups (PG 1-3) according to the stage of eruption of their second and third molars. In PG 1 (18 patients), eruption of the second molars had either not yet taken place or was not complete. In PG 2 (15 patients), the second molars had already developed as far as the occlusal plane, with the third molars at the budding stage. In PG 3 (3 patients), germectomy of the wisdom teeth had been carried out, and the first and second molars on both sides had completely erupted. Analysis of cephalograms to identify any changes in the sagittal plane showed that, in the direction of distalization, a tooth bud acts on the mesial neighboring tooth like a fulcrum, and that tipping of the first molars in patients in whom the second molar was still at the budding stage was thus greater. In patients whose second molars had erupted completely, the degree of tipping was greater again when a third molar bud was located in the direction of movement. After previously completed germectomy of the wisdom teeth, almost exclusively bodily distalization of both molars is possible, even without bands being applied to the second molars. However, if the first and second molars are distalized simultaneously with a pendulum appliance, the duration of therapy will be longer, greater forces will have to be applied, and more anchorage will be lost. Statistical analysis of the results of dental-angular measurements showed significant differences in the degree of molar tipping and reciprocal incisor protrusion. The degree of distal tipping of first molars was less in patients with erupted second molars (PG 2 and PG 3) than in those whose second molars were not yet erupted (PG 1). For instance, the measured angles were 0.9 degrees +/- 3.43 degrees (to the palatal plane) and 0.8 degrees +/- 3.4 degrees (to the anterior cranium floor) in PG 2, and -0.33 degrees +/- 0.58 degrees and 0.67 degrees +/- 2.08 degrees, respectively, in PG 3, contrasting with respective values of 5.89 degrees +/- 3.74 degrees and 5.36 degrees +/- 3.49 degrees in PG 1. Tipping of erupted second molars was much more marked in PG 2 (7.92 degrees +/- 5.83 degrees to the palatal plane and 7.55 degrees +/- 5.28 degrees to the anterior cranium floor), but much less pronounced in PG 3 (2 degrees +/- 1.73 degrees to the palatal plane and 2 degrees +/- 2 degrees to the anterior cranium floor) than the corresponding movement of the second budding-stage molars in PG 1 (4.06 degrees +/- 2.15 degrees and 3.97 degrees +/- 2.27 degrees, respectively). The degree of incisor protrusion occurring reciprocally with molar distalization was much less in these patients (measured angles of 3.28 degrees +/- 1.97 degrees and 2.89 degrees +/- 2.17 degrees to the palatal plane and anterior cranium floor, respectively) than in the patients presenting different stages of the dentition (angles of 5.5 degrees +/- 3.33 degrees and 6.03 degrees +/- 4.29 degrees, respectively, in PG 2, and angles of 5.5 degrees +/- 3.28 degrees and 6.67 degrees +/- 3.09 degrees, respectively, in PG 3). Moreover, measurement of dental casts in the horizontal plane showed not only the targeted mesiobuccal rotation of both maxillary molars, but also a vestibular drift of the unbanded second molars.

Activator Appliances↗

Determination of the mechanical properties of the periodontal ligament in a uniaxial tensional experiment.

BACKGROUND: The periodontal ligament is a soft connective tissue which joins the tooth root to the alveolus and thus provides for anchorage of the tooth in the alveolar bone. Due to its composition of elastic and viscous components, this tissue displays viscoelastic material properties. In a previous study [4], in vitro experiments revealed typical viscoelastic material properties of the periodontal ligament in samples from pig mandibles. These properties included force relaxation, hysteresis, and dependence on loading history. MATERIAL AND METHODS: Based on those experiments, a dependence of tooth displacement on loading velocity was registered in the present study and the stress-strain behavior of the periodontal ligament was examined until the tissue ruptured. For this purpose, segments of the periodontal ligament taken from anterior teeth from the pig mandible were tested in a purpose-developed clamping fixture in a uniaxial tensional experiment. RESULT: It was found that the initial phase of the stress-strain curve in particular was dependent on loading velocity and that the shape of the hysteresis curve was subject to a variation in loading velocity. The stress-strain behavior of the periodontal ligament was characterized, divided into several phases, and the elastic modulus of the initial and the linear phase of the curve was determined at different loading velocities. CONCLUSION: Knowledge of the material properties of the periodontal ligament is fundamental to an understanding of orthodontic tooth movement and thus to selection of an optimal force system for orthodontic treatment.

Animals↗

Dynamic functional force measurements on an anterior bite plane during the night.

BACKGROUND: Anterior bite planes are used in removable and fixed appliance treatment. In removable appliance treatment the question arising is whether the delivered forces can achieve active intrusion in terms of their amplitude and duration. In fixed appliance treatment, the force effect on the incisors and associated pathologic side effects, in particular under the application of intrusion mechanics, have to be considered. SUBJECTS AND METHOD: The aim of the present study was to investigate the effects of an anterior bite plane during the night. For this purpose ten subjects underwent nocturnal sleep investigations by means of a telemetric system. A silicon force sensor was integrated into an anterior bite plane for continuous measurement of bite forces and of the frequency of occlusal contact with the plate. RESULTS: The occlusal forces exerted on the anterior bite planes ranged between 3 and 80 N. The average forces were 5.5-24 N. The number of occlusal contacts varied between 39 and 558, with forces of between 7 and 9 N being registered in most cases. Major interindividual differences were detected in the magnitude of the force as well as in bite frequency. The intraindividual pattern of arising occlusal forces showed an intermittent force effect. No significant differences were found with regard to gender or growth pattern. CONCLUSIONS: In subjects with removable appliances, no active intrusion of teeth is possible during the night owing to the small number of occlusal contacts. Due to the partially very high forces in fixed appliance therapy, the integration of an anterior bite plane has to be assessed as critical in patients with unfavorable root geometry or bruxism.

Adult↗

Experiments to determine the material properties of the periodontal ligament.

PHYSIOLOGY OF THE PERIODONTAL LIGAMENT: The periodontal ligament is a soft biological tissue that controls tooth movement under physiological loads by joining tooth and alveolar bone. Its various components differ in their material properties. Their spatial configuration and interaction are responsible for the reaction of the tissue in a loading situation. Due to the combination of fluid and elastic elements the periodontal ligament shows a viscoelastic behavior typical of soft biological tissues. It is characterized by non-linearity and time dependency, and additionally depends on loading history. BEHAVIOR UNDER EXTERNAL LOADS: In orthodontics, external loads are applied to the tooth crowns using orthodontic appliances. Since stresses and strains in the periodontal tissue, caused by the initial tooth movement, stimulate alveolar bone remodeling and thus orthodontic tooth movement, knowledge of the material properties of the periodontal ligament is fundamental to selection of an optimal force system for targeted tooth movement. OWN EXPERIMENTS: For this reason, typical properties of the viscoelastic material behavior of the periodontal ligament were tested experimentally in the present study, using samples from pig mandibles. This enabled the properties of force relaxation and hysteresis of this tissue, both of which depend on loading history, to be verified. CONCLUSION: The experimental results allow characterization of the tissue and thus contribute to an understanding of the biomechanics of tooth displacement under externally applied loads.

Animals↗

Contactless measurement of canine retraction by digital macrophotogrammetry during hybrid retractor application.

A new contactless method for measuring tooth movements is presented. Digital macrophotogrammetry (DMP) enables the orthodontist to obtain information on the three-dimensional movement of a tooth at each session. Analysis of the DMP images provides information on the translation and toration of a tooth during treatment. It is conceivable that the introduction of DMP will make an important contribution to quality assurance.DMP application during canine retraction with the Hybrid Retractor((R)) has pave the way for the orthodontic appliance to be correctly adjusted at each session. Despite intra- and interindividual differences during canine movement, for which the anisotropy of the bone seems to be basically responsible, a movement velocity of ca 1.2 mm is to be expected over the entire treatment period. The preconditions for the three-dimensional orientation and description of canine movement are:1. The markers on the brackets and attachments must be clearly visible throughout the treatment.2. The teeth to which the scaling frame is fixed should not move during treatment.3. Four measuring points should be visible on each bracket.4. The control points on the frame must be positioned three-dimensionally, and it must be possible to determine their position with sufficient accuracy in advance. In vitro calibration of the photogrammetry presented here yielded a resolution of 1 micrometer for translation and of better than 1/10 degrees for rotation around the three spatial axes under optimal conditions.

Cuspid↗

Numerical experiments on long-time orthodontic tooth movement.

In orthodontic treatment, teeth are moved by the use of specific force systems. The force system used depends on the patient's orthodontic situation characterized by the geometry of the tooth and the surrounding alveolar bone, which defines the position of the center of resistance. Therefore, the simulation of bone remodeling could be helpful for the treatment strategy. In this study, the optimal force system for bodily movement of a single-root tooth, with an orthodontic bracket attached, was determined. This was achieved by the use of the numerical finite element method, including a distinct mechanical bone-remodeling algorithm. This algorithm works with equilibrium iterations separated in 2 calculation steps. Furthermore, a parametric 3-dimensional finite element model, which allows modifications in the root length and its diameter, is described. For different geometries, the ideal moment-by-force ratios that induce a bodily movement were determined. The knowledge of root geometry is important in defining an optimal force system.

Algorithms↗