PubMed Health⌕ Search

Biomedical subjects

Fred Hendrikse

Publications and source records attributed to Fred Hendrikse.

25 records · Page 2Linked to original sources

The gatekeeper in vision care. An analysis of the co-ordination of professional services in The Netherlands.

Data from a national survey were used to explore the position of ophthalmologists, general practitioners, orthoptists, optometrists and opticians in the domain of vision care services. Options for organising the gatekeeper function were analysed. This was done on the basis of six cases that the five key occupations considered as their overlapping areas. Nearly all respondents reported to be consulted by patients with the given complaints, indicating rather unclear boundaries between the professions. Further, the opinions indicated preference for a medical gatekeeper (ophthalmologist, GP) rather than a non-medical one (optometrist). Lack of agreement on suggested gatekeeper options suggest other options to consider, like regional networks of GPs, ophthalmologists, orthoptists and optometrists who share the responsibility for a specified client population. At present, such innovative arrangements are being introduced. GPs and optometrists could share the responsibility for gate-keeping and for referring patients to more specialised services.

Attitude of Health Personnel↗

Factors related to fear in patients undergoing cataract surgery: a qualitative study focusing on factors associated with fear and reassurance among patients who need to undergo cataract surgery.

The aim was to identify factors that are related to fear among patients who need to undergo cataract surgery. The data were collected by focus group interviews (n=27). The doctor-patient relationship, patient education, the wait, hospital organization, social support, sensations, previous experience, outcome of surgery, and coping strategies were identified as the main factors that contribute to feelings of fear related to cataract surgery. Five stages of fear were identified: at home after diagnosis, during preparation for surgery at the hospital, the day of surgery, the post-operative visits, and the period after these follow-up visits at home. A model regarding the factors related to fear in patients awaiting cataract surgery was developed, which emphasizes the importance of a good doctor-patient relationship, and the need for patient education that is tailored to the individual patients.

Aged↗

Quality of care from the perspective of the cataract patient. QUOTE cataract questionnaire.

PURPOSE: To examine the potential of a questionnaire (QUOTE Cataract) to measure quality of care from the perspective of cataract patients in quality-assurance or improvement programs. SETTING: Department of Ophthalmology, University Hospital Maastricht, Maastricht, University Hospital Groningen, Groningen, and Rotterdam Eye Hospital, Rotterdam, The Netherlands. METHODS: Cataract patients (N = 540) who had cataract surgery 2 to 8 months previously rated 31 quality-of-care aspects in terms of importance (range 0, not important, to 10, extremely important) and performance (0 = yes, 1 = no). An arithmetic combination of the 2 parameters was used to generate quality-impact factors (Q) (range 0, best quality of care, to 10, this aspect needs improvement according to every respondent). The goal was to identify bottlenecks in the quality of care. RESULTS: Patients scored aspects concerning patient education as the most important quality aspects. The top 3 quality-impact factors were to inform patients what to do in emergency situations (Q = 3.39), inform patients about the risks of treatment (Q = 3.00), and minimize the number of ophthalmologists to 1 per patient (Q = 2.79). CONCLUSIONS: The QUOTE Cataract Questionnaire effectively measured quality of care in cataract surgery patients in different hospital settings and provided practical information for quality-assurance programs.

Aged↗

Optimising RGP lens fitting in normal eyes using 3D topographic data.

PURPOSE: To analyse, retrospectively, the effect of fitting characteristics on comfort of wear and the role that 3D topographic data can play in attaining an optimal lens fit with rigid gas permeable (RGP) contact lenses in normal eyes. METHODS: Included were 60 normal myopic eyes (1.00-5.00 D) with astigmatism limited to 2.00 D. Lenses were ordered empirically, based on traditional fitting rules. RESULTS: The initial fit based on traditional computation was accepted in 40% of the eyes. To achieve an acceptable fit, 15% of the eyes needed an adaptation of the back optic zone radius, in 28% switching from a multicurve to an aspheric lens design was indicated and in 17% a non-rotational symmetric lens design was favoured. The reason for changing the lens parameters could in 88% be attributed to mid-peripheral differences between corneal shape as found with 3D corneal topography. Average comfort of wear improved statistically significantly (chi(2), P<0.05) from 5.2 initially to 7.7 after 3 months in the group with optimal lens fits, while comfort slightly decreased (not significant) in the group with sub-optimal fits. Switching to a non-rotational symmetric lens design, when indicated, improved comfort significantly (chi(2), P<0.05) from 5.0 to 7.3. CONCLUSION: In normal eyes, the measurement of corneal shape, especially in the mid-peripheral regions, is of importance to optimise RGP lens fit. Optimised lens fits increases comfort of wear.

Journal Article↗

In vitro human scleral permeability of fluorescein, dexamethasone-fluorescein, methotrexate-fluorescein and rhodamine 6G and the use of a coated coil as a new drug delivery system.

PURPOSE: To determine the in vitro human scleral permeability of several dyes and drugdye combinations with varying molecular weights (MW) and lipid solubilities (fluorescein, dexamethasone-fluorescein, methotrexate-fluorescein, and rhodamine). Coils coated with rhodamine were also evaluated for scleral permeability and sustained release. METHODS: Scleral sections excised from moist chamber stored human globes were mounted in a 2-compartment perfusion chamber. A small depot of drug/dye (100 microl of 10(-4) M fluorescein, dexamethasone-fluorescein, methotrexate-fluorescein or rhodamine) or a coated coil in 100 microl of BSS was added to the episcleral surface while perfusing BSS to the choroidal side. The perfusate was collected and measured for fluorescence. Permeability was calculated as Ktrans from the flux measurements. RESULTS: Ktrans values (cm/sec, mean +/- SE) for the studied dyes and drug-dye combinations were 5.21 +/- 0.71 x 10(-6) for fluorescein, 1.64 +/- 0.17 x 10(-6) for dexamethasone-fluorescein, 3.36 +/- 0.62 x 10(-6) for methotrexate-fluorescein, 1.86 +/- 0.39 x 10(-6) for rhodamine and 2.18 +/- 0.23 x 10(-6) for the rhodamine from the coils. We found a significant difference between the permeability of the sclera to fluorescein and dexamethasone-fluorescein (P < 0.001), methotrexate-fluorescein (P < 0.05) and rhodamine (P < 0.001). Steady state flux was observed from the rhodamine coil. CONCLUSION: The rank order of scleral permeability to the studied dyes is as follows: fluorescein > methotrexate-fluorescein > rhodamine coil > rhodamine 6G > dexamethasone-fluorescein. Differences in scleral permeability are related to MW and lipid solubility. Prolonged transscleral diffusion of rhodamine delivered by solution and by coil are similar.

Coated Materials, Biocompatible↗

Remote temperature monitoring in ocular tissue using confocal Raman spectroscopy.

We demonstrated the feasibility of Raman spectroscopy for remote temperature monitoring within the aqueous humor of the rabbit eye in vivo. Using a confocal Raman spectroscopy system, Raman spectra from 2580 to 3800 cm(-1) were recorded in HPLC-grade water and in the aqueous humor of the rabbit eye under in vivo and ex vivo conditions within a temperature range of 14-34 degrees C. The ratio between the integrated Raman intensities of two temperature dependent OH-vibrational regions (OH2/OH1) in the spectra of water showed high linear dependence on temperature both in pure water [0.0049(+/-1.2%)T+0.4522(+/-0.5%), R2=0.99, n=50, p<0.05], as well as in the rabbit aqueous humor [0.0036(+/-2.8%)T+0.4966(+/-0.6%), R2=0.98, n=162, p<0.05] with a high degree of reproducibility and sensitivity ( approximately 0.2-0.7 degrees C). Raman spectroscopy can be used for high resolution and remote monitoring of temperature in the aqueous humor under in vivo conditions.

Animals↗