PubMed Health⌕ Search

Biomedical subjects

Fred Morady

Publications and source records attributed to Fred Morady.

At least 55 records · Page 3Linked to original sources

Noninducibility of atrial fibrillation as an end point of left atrial circumferential ablation for paroxysmal atrial fibrillation: a randomized study.

BACKGROUND: An anatomic approach of left atrial radiofrequency circumferential ablation (LACA) to encircle the pulmonary veins is often effective in eliminating paroxysmal atrial fibrillation (AF). However, no electrophysiological end points other than voltage abatement and/or conduction slowing or block across ablation lines have been used. It has been unclear whether noninducibility of AF is a clinically useful end point. METHODS AND RESULTS: In 100 patients with paroxysmal AF (mean age, 55+/-10 years), LACA to encircle the left- and right-sided pulmonary veins was performed during AF, with additional ablation lines in the posterior left atrium and mitral isthmus, with an 8-mm-tip catheter. After completion of this lesion set, sinus rhythm was present, and AF lasting >60 seconds was not inducible in 40 patients (40%; group 1). The 60 patients in whom AF was still present or who still had inducible AF were randomly assigned to no further ablation (group 2; 30 patients) or to additional ablation lines along the left atrial septum, roof, and/or anterior wall where there were fractionated electrograms (group 3; 30 patients). In group 3, AF was rendered noninducible in 27 of 30 patients (90%). At a 6-month follow-up, 67% of patients in group 2 were free of AF without drug therapy compared with 86% of patients in group 3. (P=0.05, log-rank test). Left atrial flutter occurred in 17% and 27% of patients in each group, respectively (P=0.3). CONCLUSIONS: After LACA in patients with paroxysmal AF, AF usually can be rendered noninducible by additional ablation at sites of fractionated electrograms. Noninducibility of AF attained by additional electrogram-guided left atrial ablation may be associated with a better midterm clinical outcome than when AF is still inducible after LACA alone.

Aged↗

Clinical significance of inducible atrial flutter during pulmonary vein isolation in patients with atrial fibrillation.

OBJECTIVES: This study was designed to determine the prevalence and clinical significance of atrial flutter (AFL) that occurs during catheter ablation for atrial fibrillation (AF). BACKGROUND: Atrial flutter frequently occurs in patients with AF. METHODS: Pulmonary vein isolation was performed in 133 consecutive patients (age 52 +/- 11 years) for paroxysmal (n = 112) or persistent (n = 21) AF. A clinical episode of AFL was documented in 40 of the 133 patients (30%). During the ablation procedure, AFL occurred in 86 patients (65%), either spontaneously (n = 36) or by rapid atrial pacing (n = 50), with AFL being typical in the majority (80%). Cavo-tricuspid isthmus ablation was performed in 28 of the 133 patients. RESULTS: Among the 105 patients who did not undergo isthmus ablation, 25 patients (24%) were documented to have symptomatic AFL during a mean follow-up of 609 +/- 252 days. Among the clinical variables of age, gender, history of clinical AFL, ejection fraction, left atrial diameter, duration of AF, and occurrence of AFL during ablation, only a history of clinical AFL (p = 0.05) and occurrence of typical AFL during the ablation (p = 0.01) were independent predictors of symptomatic AFL during follow-up. The incidence of symptomatic AFL during follow-up was similar among patients who did and did not have long-term freedom from recurrent AF. CONCLUSIONS: In patients with AF who have either a history of AFL or an episode of typical AFL during an electrophysiologic study, symptomatic AFL is common after pulmonary vein isolation. Therefore, cavo-tricuspid isthmus ablation is appropriate during pulmonary vein isolation if AFL has been observed clinically or in the electrophysiology laboratory.

Atrial Fibrillation↗

Atrio-esophageal fistula as a complication of percutaneous transcatheter ablation of atrial fibrillation.

BACKGROUND: Radiofrequency ablation for atrial fibrillation is becoming widely practiced. METHODS AND RESULTS: Two patients undergoing circumferential pulmonary vein ablation for atrial fibrillation in different centers developed symptoms compatible with endocarditis 3 to 5 days after the procedure. Their clinical condition deteriorated rapidly, and both suffered multiple gaseous and/or septic embolic events causing cerebral and myocardial damage. One patient survived after emergency cardiac and esophageal surgery; the other died of extensive systemic embolization. An atrio-esophageal fistula was identified in both patients. CONCLUSIONS: Atrio-esophageal fistulas can occur after catheter ablation in the posterior wall of the left atrium. This diagnosis should be excluded in any patient with symptoms or signs of endocarditis after left atrial ablation, and expeditious cardiac surgery is critical if the diagnosis is confirmed. Lower power and temperature settings for applications of radiofrequency energy along the posterior left atrial wall may prevent further cases of fistula formation.

Adult↗

Randomized comparison of anatomical versus voltage guided ablation of the cavotricuspid isthmus for atrial flutter.

OBJECTIVES: The purpose of this prospective study was to compare radiofrequency catheter ablation of the cavotricuspid isthmus using a strictly anatomic approach to an approach guided by a bipolar voltage map to avoid high voltage zones in the cavotricuspid isthmus. BACKGROUND: It is not clear whether local atrial electrogram amplitude influences the achievement of complete cavotricuspid isthmus block during radiofrequency catheter ablation for atrial flutter. METHODS: Thirty-two patients with atrial flutter were randomized to cavotricuspid isthmus ablation using an anatomical approach (group I, 16 patients) or guided by a bipolar voltage map (group II, 16 patients). A 3-dimensional electroanatomic mapping system and an 8-mm-tip ablation catheter were used in all patients. With the anatomical approach, an ablation line was created in the cavotricuspid isthmus at a 6 o'clock position in the 45 degree left anterior oblique projection. During voltage-guided ablation, a high-density bipolar voltage map of the cavotricuspid isthmus was created, and then contiguous applications of radiofrequency energy were delivered to create an ablation line through the cavotricuspid isthmus sites with the lowest bipolar voltage. RESULTS: Complete cavotricuspid isthmus conduction block was achieved in 100% of patients in each group. The mean maximum voltages along the line were 3.6 +/- 1.5 mV in group I, and 1.2 +/- 0.9 mV in group II (P < .01). Creating a high-density voltage map was associated with approximately 15-minute increase in the total procedure time (P = .2). During a mean follow-up of 177 +/- 40 days, there were no recurrences of atrial flutter in either group. There were no complications in either group. CONCLUSIONS: When cavotricuspid isthmus ablation for atrial flutter is performed with an 8-mm-tip catheter, complete block can be achieved in all patients regardless of local voltage. Ablation of high voltage zones is not associated with a higher recurrence rate. Therefore, anatomic ablation without voltage mapping is the preferred initial approach for cavotricuspid isthmus ablation.

Atrial Flutter↗

Mechanisms of recurrent atrial fibrillation after pulmonary vein isolation by segmental ostial ablation.

OBJECTIVES: The aim of this study was to determine the mechanisms responsible for recurrent atrial fibrillation (AF) after pulmonary vein isolation (PV) by segmental ostial ablation. BACKGROUND: Recovery of conduction into a previously isolated PV is a common observation when there is recurrent AF soon after segmental ostial ablation. However, the mechanisms of recurrent AF have been unclear. METHODS: A repeat ablation procedure was performed in 50 patients who had recurrent paroxysmal AF at a mean of 7 +/- 6 months after segmental ostial ablation to isolate the PVs. During the repeat procedure, a ring catheter was inserted into each PV during sinus rhythm and AF to determine whether the veins were still isolated and, if not, whether there were PV tachycardias with a cycle length shorter than in the adjacent left atrium during AF. RESULTS: There was recovery of conduction over a previously ablated muscle fascicle in >/=1 PV in 49 patients (98%). There were 10 +/- 2 episodes of PV tachycardia per minute in 36 (72%) of the 50 patients during AF. Repeat ablation was performed by segmental ostial ablation (23 patients) or by left atrial catheter ablation to encircle the left- and right-sided PVs 1 to 2 cm from the ostia, with additional ablation lines in the posterior left atrium and mitral isthmus (27 patients). At 6-month follow-up, among 23 patients who underwent repeat ablation by segmental ostial ablation, AF recurred in 4 (21%) of the 19 patients who had PV tachycardias and in 3 (75%) of the 4 patients who did not (P = .03). Among the 27 patients who underwent left atrial ablation, AF recurred in 2 (12%) of the 17 patients who had PV tachycardias and in 1 (10%) of the 10 patients who did not (P = 0.7). CONCLUSIONS: Recovery of conduction in previously ablated muscle fascicles is a common finding in patients with recurrent AF after segmental ostial ablation. The efficacy of repeat segmental ostial ablation depends on the presence of PV tachycardias, whereas left atrial ablation is effective regardless of whether PV tachycardias are present or not during AF.

Atrial Fibrillation↗

Percutaneous epicardial mapping during ablation of difficult accessory pathways as an alternative to cardiac surgery.

OBJECTIVES: The aim of this study was to define the role of percutaneous epicardial mapping for the ablation of previous failed ablation of accessory pathways. BACKGROUND: Cardiac surgery is the only curative option for failed radiofrequency (RF) catheter ablation of accessory pathway (AP)-mediated tachycardias. We investigated a combined percutaneous epicardial and endocardial approach for failed AP ablations. METHODS: We present our experience in a series of 6 cases (7 APs) with previous failed attempts at catheter ablation (median 2 attempts, range 1-4) and persistent symptomatic tachycardias. Endocardial mapping of the APs was performed using conventional techniques. Sites with local electrograms suggestive of AP location were selected. When initial endocardial mapping was not successful for ablation of the pathway, percutaneous transthoracic pericardial puncture was performed via a subxiphoid approach, and an ablation catheter was positioned at the epicardial aspect of the putative AP location for epicardial-endocardial electrogram comparison. Endocardial RF energy was applied to locations considered appropriate. Epicardial RF applications were delivered when endocardial applications failed. Coronary arteriography was performed to assess the proximity of coronary arteries to the ablation catheter. RESULTS: APs were located in the right free wall (4 patients, 5 APs) and the right (1 patient) and left (1 patient) posteroseptal regions. In all patients, epicardial mapping assisted in identifying successful ablation sites. In 3 patients, the earliest atrial activation during orthodromic tachycardia was present in an epicardial electrogram. Successful AP ablation was achieved with an epicardial RF application in 2 patients, either alone or with simultaneous endocardial-epicardial delivery. In the remaining 4 patients, APs were successfully ablated endocardially after epicardial mapping. These patients represent 18% of all cases referred to our institution for ablation of previously failed accessory pathways (6/32 patients). CONCLUSIONS: A combined endocardial-epicardial approach to mapping and RF ablation can facilitate successful endocardial ablation in most cases. In selected cases, APs can be ablated by epicardial delivery of RF. Epicardial mapping is an effective alternative to cardiac surgery for patients in whom prior attempts at AP ablation have failed.

Adolescent↗

Catheter ablation guided by termination of postinfarction ventricular tachycardia by pacing with nonglobal capture.

OBJECTIVES: We prospectively investigated the prevalence and value of this criterion for identifying a target site for ablation in patients with postinfarction ventricular tachycardia (VT). BACKGROUND: Termination of postinfarction VT by pacing with nonglobal capture identifies a critical component of the reentrant circuit. METHODS: In a consecutive series of 34 patients with prior infarction (age 67 +/- 10 years, ejection fraction 0.26 +/- 0.1) referred for radiofrequency catheter ablation, mapping was performed in the left ventricle. At sites with abnormal electrograms, pacing was performed during VT. If VT terminated with nonglobal capture during the pacing train, radiofrequency energy was delivered. RESULTS: Sixty-two VTs (cycle length 450 +/- 84 ms) were mapped and targeted for radiofrequency ablation. Concealed entrainment was present at 101 endocardial sites. Among the 101 sites, VT terminated by pacing with nonglobal capture at 5 sites (5%). At 10 additional sites in 10 patients, VT terminated by pacing with nonglobal capture, and concealed entrainment could not be documented at these sites because of reproducible termination of the VT. An application of radiofrequency energy resulted in VT termination at all 15 sites where nonglobal capture was documented and the targeted VTs were no longer inducible after ablation. CONCLUSIONS: Termination of VT by pacing with nonglobal capture can be demonstrated in approximately one third of patients with postinfarction VT and is a specific criterion for identifying a critical component of the reentrant circuit, whether or not concealed entrainment can be documented at that site.

Aged↗

Effects of left atrial ablation of atrial fibrillation on size of the left atrium and pulmonary veins.

OBJECTIVES: The purpose of this study was to determine the effect of left atrial circumferential ablation on the size of the left atrium and pulmonary veins (PVs). BACKGROUND: The long-term effects of left atrial circumferential ablation on left atrial and PV size and anatomy have not been analyzed in quantitative fashion. METHODS: PV and left atrial sizes were analyzed in 41 consecutive patients (mean age 54 +/- 12 years) with paroxysmal (n = 25) or chronic (n = 16) atrial fibrillation. Computed tomography of the chest with three-dimensional reconstruction was performed before and 4 +/- 2 months after left atrial circumferential ablation. Left atrial circumferential ablation was performed to encircle the PVs 1 to 2 cm from the ostia, using a power output of 70 W. Additional ablation lines were created in the posterior left atrium and mitral isthmus. Radiofrequency energy also was delivered within the circles and at the PV ostia in 51% of patients at a reduced power output of 35 W. RESULTS: At 6 months, 36 patients (88%) were in sinus rhythm without antiarrhythmic drug therapy, including 3 patients (7%) who developed persistent left atrial flutter and underwent subsequent successful ablation of atrial flutter. There was a 15 +/- 16% decrease in left atrial volume (P < .01) and 10 +/- 35% decrease in PV ostial area (P < .01), without focal narrowing, in patients with a successful outcome. Focal PV stenosis did not occur in any of the 41 patients. CONCLUSIONS: Maintenance of sinus rhythm after left atrial circumferential ablation is associated with reduced left atrial and PV ostial size. Left atrial circumferential ablation for atrial fibrillation does not cause PV stenosis.

Atrial Fibrillation↗

Relative timing of isolated potentials during postinfarction ventricular tachycardia and sinus rhythm.

BACKGROUND: In postinfarction patients, isolated potentials separated by an isoelectric segment from the ventricular electrogram indicate areas of block. Isolated potentials can be recorded during both sinus rhythm and ventricular tachycardia (VT). In an attempt to differentiate bystander pathways from critical sites within a reentry circuit, we compared the relative timing of isolated potentials during VT and sinus rhythm. METHODS: In 19 patients (mean age 68 +/- 6 years) with postinfarction VT who were referred for VT ablation, mapping was performed in the presence and absence of VT. Forty-three sites at which there was concealed entrainment during 35 VT's (mean cycle length 469 +/- 74 ms) displayed an isolated potential separated from the main portion of the ventricular electrogram by an isoelectric segment of >/=30 msec in the presence and absence of VT. The interval between the ventricular electrogram and the isolated potential was measured during VT and baseline rhythm, and the absolute difference (DeltaIPI) was calculated. The DeltaIPI was significantly greater at effective ablation sites (119 +/- 69 ms) than at ineffective ablation sites (30 +/- 28 ms, p < 0.001). The positive predictive value of a DeltaIPI > 85 ms for an effective ablation site was 100%. CONCLUSION: At sites of concealed entrainment, an absolute difference >85 ms between the isolated potential intervals during sinus rhythm and VT is highly specific for a critical area of the VT reentry circuit in post-infarction patients.

Action Potentials↗

Acute effects of left atrial radiofrequency ablation on atrial fibrillation.

INTRODUCTION: Acutely, when left atrial ablation is performed during atrial fibrillation (AF), the AF may persist and require cardioversion, or it may convert to sinus rhythm or to atrial tachycardia/flutter. The prevalence of these acute outcomes has not been described. METHODS AND RESULTS: Left atrial ablation, usually including encirclement of the pulmonary veins, was performed during AF in 144 patients with drug-refractory AF. Conversion to sinus rhythm occurred in 19 patients (13%), to left atrial tachycardia in 6 (4%), and to atrial flutter in 6 (4%). In the 6 patients with a focal atrial tachycardia, the mean cycle length was 294 +/- 45 ms. The tachycardia arose in the left atrial roof in 3 patients, the left atrial appendage in 2, and the anterior left atrium in 1. In 3 of 6 patients, the focal atrial tachycardia originated in an area that displayed a relatively short cycle length during AF. In 6 patients, AF converted to macroreentrant atrial flutter with a mean cycle length of 253 +/- 47 ms, involving the mitral isthmus in 5 patients and the septum in 1 patient. All atrial tachycardias and flutters were successfully ablated with 1 to 15 applications of radiofrequency energy. CONCLUSION: When left atrial ablation is performed during AF, the AF may convert to atrial tachycardia or flutter in approximately 10% of patients. Focal atrial tachycardias that occur during ablation of AF may be attributable to driving mechanisms that persist after AF has been eliminated, whereas atrial flutter results from incomplete ablation lines.

Acute Disease↗

Pulmonary vein isolation for vagotonic, adrenergic, and random episodes of paroxysmal atrial fibrillation.

INTRODUCTION: Based on the clinical history, paroxysmal atrial fibrillation (PAF) may be classified as vagotonic, adrenergic, or random. It is unclear whether pulmonary vein (PV) isolation is equally effective for these types of PAF. METHODS AND RESULTS: Segmental ostial ablation to isolate the PVs was performed in 188 consecutive patients (mean age 53 +/- 12 years) with PAF. Based on the clinical history, PAF was classified as random in 136 patients (72%), adrenergic in 30 (16%), and vagotonic in 22 (12%). Three or four PVs were targeted for isolation in all patients, and successful isolation was achieved in 96% of targeted PVs. At 1-year follow-up, 69% of patients with random AF, 83% of patients with adrenergic AF, and 50% of patients with vagotonic AF were free from recurrent episodes of AF in the absence of any antiarrhythmic drug therapy. Vagotonic AF was an independent clinical predictor of recurrent AF (P = 0.03). CONCLUSION: PV isolation has a lower efficacy in patients with vagotonic PAF than in patients with adrenergic or random episodes of PAF, suggesting that the PVs less often play an important role in vagotonic PAF.

Atrial Fibrillation↗

Detection of inadvertent catheter movement into a pulmonary vein during radiofrequency catheter ablation by real-time impedance monitoring.

INTRODUCTION: During radiofrequency ablation to encircle or isolate the pulmonary veins (PVs), applications of radiofrequency energy within a PV may result in stenosis. The aim of this study was to determine whether monitoring of real-time impedance facilitates detection of inadvertent catheter movement into a PV. METHODS AND RESULTS: In 30 consecutive patients (mean age 53 +/- 11 years) who underwent a left atrial ablation procedure, the three-dimensional geometry of the left atrium, the PVs, and their ostia were reconstructed using an electroanatomic mapping system. The PV ostia were identified based on venography, changes in electrogram morphology, and manual and fluoroscopic feedback as the catheter was withdrawn from the PV into the left atrium. Real-time impedance was measured at the ostium, inside the PV at approximately 1 and 3 cm from the ostium, in the left atrial appendage, and at the posterior left atrial wall. There was an impedance gradient from the distal PV (127 +/- 30 Omega) to the proximal PV (108 +/- 15 Omega) to the ostium (98 +/- 11 Omega) in each PV (P < 0.01). There was no significant impedance difference between the ostial and left atrial sites. During applications of radiofrequency energy, movement of the ablation catheter into a PV was accurately detected in 80% of the cases (20) when there was an abrupt increase of >/=4 Omega in real-time impedance. CONCLUSION: There is a significant impedance gradient from the distal PV to the left atrium. Continuous monitoring of the real-time impedance facilitates detection of inadvertent catheter movement into a PV during applications of radiofrequency energy.

Adult↗

Prevalence of asymptomatic recurrences of atrial fibrillation after successful radiofrequency catheter ablation.

INTRODUCTION: The long-term efficacy of radiofrequency catheter ablation of atrial fibrillation (AF) has been based on patient-reported symptoms suggestive of AF. However, asymptomatic recurrences of AF may remain undetected. The aim of this study was to determine the prevalence of asymptomatic recurrences of AF after an apparently successful catheter ablation procedure for AF. METHODS AND RESULTS: Among 244 consecutive patients (mean age 53 +/- 11 years) who underwent a pulmonary vein isolation procedure for symptomatic paroxysmal AF and who reported no symptoms of recurrent AF at > or =6 months after the procedure, 60 patients with a history of > or =1 episode of AF per week were asked to participate in this study. Preablation, these patients had experienced 19 +/- 13 episodes of AF per month. The patients were provided with a patient-activated transtelephonic event recorder for 30 days, a mean of 642 +/- 195 days after the ablation procedure, and were asked to record and transmit recordings on a daily basis and whenever they felt palpitations. Seven patients (12%) felt palpitations during the study, although they had not experienced symptoms previously. Each of these 7 patients had an episode of AF documented with the event monitor during symptoms. In these 7 patients, the mean number of episodes per month decreased from 19 +/- 14 preablation to 3 +/- 1 postablation (P < 0.001). Among the 53 asymptomatic patients, an episode of AF was captured in 1 (2%) patient during the study period. CONCLUSION: Asymptomatic recurrences of AF after an apparently successful catheter ablation procedure for symptomatic paroxysmal AF are infrequent.

Atrial Fibrillation↗

Mechanism of immediate recurrences of atrial fibrillation after restoration of sinus rhythm.

An immediate recurrence of AF may occur after restoration of sinus rhythm. Although pulmonary vein (PV) isolation has been shown to prevent immediate recurrence of AF, the specific trigger for immediate recurrence of AF has not been described. In 89 consecutive patients (mean age 53 +/- 11 years) who had sinus rhythm restored by spontaneous or transthoracic cardioversion in the course of a PV isolation procedure, electrograms recorded within a PV and in the adjacent left atrium were analyzed to determine the mechanism of initiation of immediate recurrence of AF. Immediate recurrence of AF was defined as a recurrence of AF within 90 seconds after restoration of sinus rhythm. There were 124 episodes of immediate recurrence of AF at a mean of 18 +/- 23 seconds after cardioversion. Recordings within the PV that triggered the immediate recurrence of AF were available in 23 (19%) of the 124 immediate recurrence of AF episodes. Among these 23 episodes of immediate recurrence of AF, all (100%) were triggered by a burst of PV tachycardia (P < 0.001). The coupling interval and prematurity index (coupling interval/preceding sinus cycle length) of the premature depolarizations that did and did not trigger immediate recurrence of AF were 246 +/- 67 ms and 0.30 +/- 0.11 vs 378 +/- 117 ms and 0.49 +/- 0.16, respectively (P < 0.01). Immediate recurrence of AF was abolished by PV isolation. The mechanism of immediate recurrence of AF is a burst of PV tachycardia, not a single premature depolarization. Immediate recurrence of AF identifies patients with AF in whom the PVs may play a major role in the initiation of AF.

Atrial Fibrillation↗