Cardiac troponin and creatine kinase MB monitoring during in-hospital myocardial reinfarction.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to Fred S Apple.
Explore the source record for details and available documents.
With great pleasure and anticipation in recognition of Clinical Chemistry's 50th anniversary, I have been able to arm-twist four talented scientists to document their impressive marks on the science of diagnostics in the field of cardiac biomarkers and detection of myocardial infarction. Their exciting discoveries and applications have dramatically influenced the fields of laboratory medicine and cardiology and have greatly influenced the care and management of thousands of patients suffering from coronary artery disease leading to acute myocardial infarction. As a matter of historical record, I owe a great deal of thanks to each one of the coauthors of this special report because each one has personally influenced my scientific career. I met Dr. Rosalki, during my postdoctoral training, at a national AACC meeting, where he kindly answered my numerous queries regarding creatine kinase enzymology and muscle physiology. Dr. Roberts, while serving as Director of the Coronary Care Unit at Washington University in St. Louis, generously allowed this fledgling fellow into his laboratory and shared many of his clinical and experimental findings with me. Dr. Katus, whom I first met at a scientific meeting sponsored by Boehringer Mannheim in 1986 in Bavaria, where I first became fascinated with cardiac troponin T, has remained a friend and colleague. Lastly, Dr. Ladenson, who as mentor, scientific colleague, and close friend remains ultimately responsible for both my professional growth as a clinical chemist (he was my postdoctoral fellowship advisor) and for stimulating and encouraging my goals and aspirations in the field of cardiac biomarkers. With the descriptions of the ground-breaking science described below, I am extremely excited and optimistic that the future of cardiac biomarkers is secure and open to new discoveries by the Rosalkis, Robertses, Katuses, and Ladensons of the future.
BACKGROUND: In patients with end-stage renal disease (ESRD), the ability of single and multiple biomarker monitoring to predict adverse outcomes has not been well established. This study determined the prognostic value of multiple biomarkers for all-cause death over 2 years in 399 ESRD patients. METHODS: The risk of all-cause death was determined by use of multiple biomarkers based on concentrations for a reference population (normal) and cutoffs based on tertile distributions in the ESRD group. Biomarkers studied included N-terminal pro-B-type natriuretic peptide (NT-proBNP), high-sensitivity C-reactive protein (hsCRP; Dade Behring and Roche assays), and cardiac troponin T (cTnT; Roche) and I (cTnI; Dade Behring and Beckman Coulter assays). Relative risks of death were estimated and survival curves computed. RESULTS: A total of 101 deaths occurred during 594 patient-years of follow-up. Increased NT-proBNP concentrations were not predictive of death on the basis of the normal cutoffs. However, tertile analysis of NT-proBNP was significantly predictive of death and had a ROC area under the curve equivalent to or better than any of the other biomarkers. Biomarkers independently predictive of survival were hsCRP (P <0.001, either assay), cTnT (P <0.05), and cTnI (Dade, P <0.05). Two-year mortality rates were 6% (n = 45) with normal hsCRP, cTnI, and cTnT concentrations; 19% (n = 173) with increased hsCRP or cTnT and normal cTnI; 44% (n = 160) with both hsCRP and cTnT increased and normal cTnI; 61% (n = 21) with increased cTnI (Dade) or 47% (n = 74) with increased cTnI (Beckman) regardless of hsCRP or cTnT concentrations. Defined by the normal cutoffs, increased concentrations of biomarkers were present in various proportions of the 399 patients with ESRD: NT-proBNP, 99%; hsCRP, 46% (both Roche and Dade assays); cTnT, 85%; cTnI, 19% (Beckman assay) and 5% (Dade assay). CONCLUSIONS: Although mechanisms likely vary for causation, increased plasma hsCRP, cTnT, and cTnI above the cutoffs for our reference (normal) population were all independently predictive of subsequent death in ESRD patients. Tertile analysis for NT-proBNP also demonstrated prognostic value.
BACKGROUND: Creatine kinase MB (CK-MB), and cardiac troponin I (cTnI) are important biomarkers for the diagnosis and rule-out of acute myocardial infarction (AMI) of patients who presented to the emergency department (ED) with chest pain. With new rapid ED assessment protocols, there is increasing pressure to produce results with a short turnaround time (TAT), and point-of-care (POC) testing is one alternative for providing fast results. METHODS: In a multicenter study, we evaluated the analytical precision, sensitivity and specificity of the RAMP (Response Biomedical) CK-MB and cTnI POC assays and compared results against the Triage (Biosite) POC and the Dimension RxL (Dade Behring) central-laboratory assays on 365 subjects, including 185 patients suspected of AMI, and determined the normal range on 180 healthy individuals. At one site, the clinical sensitivity and specificity were estimated in 121 patients and healthy subjects with AMI using the European Society of Cardiology (ESC)/American College of Cardiology (ACC) definition of AMI. Results from healthy individuals and those with ST elevation and non-ST elevation AMI were included in a receiver operating characteristic (ROC) curve analysis. RESULTS: Intra- and total imprecision ranged from 7.2% to 11.4% for cTnI at 0.22, 1 and 5 ng/ml and 4.8% to 8.6% for CK-MB at 7, 14 and 25 ng/ml. The upper limit of linearity was 32 ng/ml with an average recovery of 105% for cTnI and 80 ng/ml with a 106% recovery for CK-MB. The lower limit of detection was 0.03 ng/ml (10% coefficient of variance [CV] = 0.21 ng/ml) for cTnI and 0.32 ng/ml for CK-MB. The upper reference limit (normal range) was < 0.03 ng/ml for cTnI and 0-3.7 ng/ml for CK-MB. Analytical correlation against Dimension RxL were RAMP=(0.456 x RxL) + 0.11 (r = 0.988, n = 364) for cTnI and RAMP=(0.966 x RxL) + 0.60 (r = 0.986, n = 363) for CK-MB and against Triage, RAMP=(0.626 x Triage) + 0.164 (r = 0.969, n = 364) for cTnI and RAMP=(0.845 x RxL) - 0.495 (r = 0.952, n = 363) for CK-MB. On 39 AMI and 67 non-AMI patients, the clinical sensitivity, specificity and diagnostic efficiency of the cTnI and CK-MB RAMP assays were not significantly different from predicate assays. CONCLUSIONS: The RAMP cardiac marker assays are alternatives to other FDA-cleared central laboratory and POC testing devices.
Patients with congestive heart failure have increased concentrations of B-type natriuretic peptide (BNP) in blood. We determined the frequency of serial BNP measurements that exceeded the biologic variation of BNP of 100% as a function of days between blood collections. Samples collected 7 days apart were associated with the highest frequency (50%) of statistically different results (increased or decreased) compared with daily collections, where increased or decreased results occurred less often (22%).
BACKGROUND: Myoglobin is a low-molecular weight protein present in the cytosol of striated muscles. Its concentrations in serum can be measured by immunoassays and are used as an early indicator of myocardial necrosis. Since variability among commercial myoglobin assays exists, standardization of myoglobin assays is needed. METHODS: An international collaborative study was organized with the involvement of seven companies using 12 different automated platforms for measuring myoglobin. Five candidate secondary, i.e., matrixed, reference materials were assayed in relation to linearity, imprecision, recovery rate and commutability to demonstrate a possible identity between the materials and the usual routine serum samples. RESULTS: One lyophilized candidate material (human heart myoglobin in human serum) was selected as the most suitable secondary reference material, based on the criteria examined. Used as a calibrator a posteriori, the bias between the various myoglobin assays for a frozen human serum pool was reduced from 32% to 13%. CONCLUSION: This study provides the basis for the selection of an internationally recognized secondary reference material.
BACKGROUND: This study determines the analytical characteristics of the i-STAT cardiac troponin I assay (cTnI; i-STAT, Princeton, NJ), a 10-min POC assay, designed to be performed at the bedside. METHODS: Three different hospitals participated in a patient specimen and analytical validation study (n=186) for the i-STAT cTnI assay carried out in real time. A total of 186 whole blood specimens (lithium heparin) were collected from patients presenting with symptoms suggestive of acute coronary syndromes (ACS) for correlation studies as well as from 162 healthy subjects for reference interval determination. Factors studied included antibody specificity, detection limit, imprecision, linearity, assay specificity, sample type stability, interferences, reference limit determination and comparison vs. the Dade Stratus CS cTnI assay. RESULTS: Total imprecision (CV) of 10% and 20% were seen at 0.09 and 0.07 microg/l, respectively. The detection limit was 0.02 microg/l. The 99th percentile reference limit was 0.08 microg/l. The assay was not affected by common interferents. An equimolar response within 5% was found for reduced and phosphorylated forms of TIC and IC complexes. Regression analysis for the i-STAT cTnI between whole blood and plasma specimens and for whole blood between the i-STAT and Stratus CS cTnI assays demonstrated slopes of 1.06 and 0.89, respectively. CONCLUSIONS: The i-STAT cTnI assay is a sensitive and precise monitor of cTnI, poised for point-of-care/near bedside clinical utilization for triage, diagnostics and risk management of acute coronary syndrome patients.
Patients with symptoms suggestive of, but at low risk for, acute coronary syndrome (ACS), who have a negative electrocardiogram (EKG) and a single normal troponin I at 6-9 h after symptom onset are frequently discharged from our Emergency Department (ED). We sought to determine their rate of adverse cardiac events at 30 days (ACE-30), defined as cardiac death or myocardial infarction (MI), by chart review, telephone interview, or county death records. Of 663 patients, data were available for 588 (89%). Mean age was 48 years; 59% were male. There were 390 patients (66%) who complained of chest pain. Previous coronary artery disease (CAD) was reported in 145 patients (25%). Two patients (0.34%) had ACE-30, both with non-ST elevation MI. There were no cases of cardiac death. None of the patients died in Hennepin County within 30 days. At our institution, low-risk patients with symptoms suggestive of ACS who are discharged home after a normal cTnI drawn 6-9 h after symptom onset have a very low incidence of cardiac events at 30 days.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
CONTEXT: Increasing numbers of patients are presenting to emergency departments with symptoms suggestive of an acute myocardial infarction. OBJECTIVE: To demonstrate the comparative performance of the Ortho Vitros Troponin I and Beckman Access AccuTnI assays used to detect myocardial infarction and to develop risk stratification schemes for all-cause death in patients who presented with myocardial ischemia symptoms that were suggestive of acute coronary syndrome (ACS). DESIGN: The prospective enrollment of patients with ACS and the measurement of serial plasma samples by 2 commercial cardiac troponin I (cTnI) assays. SETTING: A metropolitan medical center that admitted patients with ACS during a 2-month period. PATIENTS: The study population consisted of 200 consecutively admitted patients who presented with symptoms that were suggestive of ACS. RESULTS: Correlation scatterplots showed no significant bias between cTnI assays based on 659 specimens across the dynamic range of each assay. Only minor differences in slopes and intercepts were observed between assays when correlations were based across selected concentration ranges. The receiver operating characteristic curve areas for the detection of myocardial infarction were not significantly different (Ortho,.991; Beckman,.995). At the 99th percentile (Beckman, 0.04 microg/L; Ortho, 0.08 microg/L), each assay demonstrated 100% sensitivity with 78% and 80% specificity, respectively. Kaplan-Meier survival curves and the log-rank test were used to compare time-to-event data. Patients with increased baseline cTnI values had higher odds ratios of death than did those with normal concentrations. For Ortho, the 99th percentile cutoff was 5.9, and the 10% coefficient of variation cutoff was 10.3; for Beckman, the 99th percentile cutoff was 31.4, and the 10% coefficient of variation cutoff was 15.3. CONCLUSIONS: Comparable diagnostic and risk stratification abilities were demonstrated in patients with ACS by the Ortho Vitros and Beckman Access cTnI assays, with no significant analytic bias between cTnI assays.
The analytic accuracy and precision for measurement of chemical analytes in vitreous humor (VH) are critical if results are to be used in forensic pathology. The purpose of our study was to demonstrate the stability and the reproducibility of VH sodium, potassium, chloride, glucose, urea nitrogen, acetone, and beta-hydroxybutyrate in specimens obtained from both eyes in medical examiner cases. We also compared with calculated VH osmolalities. Small but significant increases were observed in VH electrolyte concentrations in specimens refrigerated 6-12 months: sodium pre 144 mmol/L, post 151 mmol/L; potassium pre 12.0 mmol/L, post 12.8 mmol/L; chloride pre 121 mmol/L, post 123 mmol/L. No differences were observed between eyes, and within-day precision for all electrolyte measurements were excellent, (<1%). Frozen specimens showed significantly higher measured (439 mOsmol/kg) as compared with calculated osmolality (305 mOsmol/kg), with 1% within-day precision and no significance between eye variation for glucose and urea nitrogen. In 20 of 24 medical cases selected for possible ketoacidosis, measurement of beta-hydroxybutyrate concentrations appears to be a promising diagnostic biomarker for confirming suspected ketosis in medical examiner cases by means of VH analysis.
BACKGROUND: Cardiac troponin I (cTnI) is a more specific and sensitive biomarker than creatine kinase MB (CKMB) for detection of myocardial damage. We report the prevalence of positive cTnI and CKMB mass among patients hospitalized with suspected acute coronary syndrome (ACS) and the potential impact of use of different reference cutoffs, particularly those proposed by European Society of Cardiology/American College of Cardiology (ESC/ACC) consensus guidelines, on rates of diagnosis of acute myocardial infarction (AMI). METHODS: We analyzed 1719 consecutive patients with suspected ACS admitted to an urban acute care hospital over a 6-month period. Patients (> or = 18 years of age) had at least two separate sets of plasma biomarkers (cTnI and CKMB) measured more than 12-24 h after admission to determine the potential rates of AMI based on different biomarker cutoff concentrations. RESULTS: The prevalence of cTnI-positive cases ranged from 10.6%, based on a cutoff of twice the ROC curve (cTnI < or =1.2 microg/L), to 25.0%, using the ESC/ACC-recommended 99th percentile cutoff (cTnI <0.1 microg/L). The prevalence of CKMB-positive cases ranged from 10.4%, with the cutoff of twice the ROC curve (CKMB < or =10.0 microg/L) to 21.7%, with the 99th percentile cutoff (CKMB <3.9 microg/L). Use of the 10% CV cutoff (cTnI < or =0.3 microg/L and CKMB <3.9 microg/L) instead of the ROC cutoff produced a 26% increase in all cTnI-positive cases. Use of the 99th percentile reference cutoff instead of the ROC curve-derived cutoff produced an 85% increase in all cTnI-positive cases. A substantial proportion of the increase in total cTnI-positive cases was derived from cTnI-positive/CKMB-negative cases: 71 (4.1%), 73 (4.2%), 98 (5.7%), and 209 (12.2%) of cTnI-positive cases were CKMB-negative, as determined by the twice the ROC, ROC, 10% CV, and 99th percentile reference cutoffs, respectively. At the 99th percentile cutoffs, 8.8% of cases were CKMB-positive/cTnI-negative. CONCLUSIONS: Use of lower reference cutoffs for plasma biomarkers, as recommended by ESC/ACC guidelines, markedly increases the rates of cTnI-positive cases overall. A substantial proportion of the increase in total cTnI-positive cases was derived from the creation of additional cTnI-positive/CKMB-negative cases. CKMB-positive/cTnI-negative cases are likely false positive for myocardial injury.
BACKGROUND: The European Society of Cardiology/American College of Cardiology Committee for the Redefinition of Myocardial Infarction (MI) has recommended that an increased cardiac troponin should be defined as a measurement above the 99th percentile value of the reference group. A total imprecision (CV) at the decision limit of </=10% is recommended. However, peer-reviewed data on assay imprecision are lacking. The purpose of this study was to construct the clinically relevant imprecision profiles for each of the commercially available cardiac troponin assays. Pools of human sera containing cardiac troponin concentrations around the MI decision limit were assessed to identify the lowest concentration associated with a 10% CV. METHODS: Eight serum pools targeting different concentrations of cardiac troponin (I and T) were prepared and stored at -70 degrees C until usage. The cardiac troponin measurement protocol consisted of two replicates per specimen per run, and one run per day for 20 days, using two reagent lots and three calibrations. Manufacturers of each cardiac troponin assay directly performed the measurements. Data analysis for each assay was centralized and performed according to the NCCLS EP5-A guideline. RESULTS: The lowest concentrations (microg/L) providing a 10% CV were as follows: AxSYM, 1.22; ACS:180, 0.37; Centaur, 0.33; Immuno 1, 0.34; Access, 0.06; Vidas, 0.36; Liaison, 0.065; Dimension, 0.26; Opus, 0.90; Stratus CS, 0.10; Immulite, 0.32; Vitros ECi, 0.44; Elecsys, 0.04; AIA 21, 0.09. CONCLUSION: No cardiac troponin assay was able to achieve the 10% CV recommendation at the 99th percentile reference limit defined by the manufacturer.
Explore the source record for details and available documents.
BACKGROUND: Brain natriuretic peptides (BNPs) are useful in the assessment of heart failure, left ventricular dysfunction, and acute coronary syndromes. METHODS: We performed a multicenter evaluation of the automated Roche NT-proBNP assay and compared its performance to the Biosite Triage BNP assay. RESULTS: The N-terminal (1-76) pro brain natriuretic peptide (NT-proBNP) method is precise (CV 2-fold higher CV, and plasma samples are more labile when stored at room temperature and 4 degrees C. Comparison studies showed a reasonable correlation between NT-proBNP and BNP assays, with a substantially higher slope bias of 6-20 for the NT-proBNP assay. CONCLUSIONS: The automated Roche NT-proBNP assay has good analytical performance and better precision than the Biosite BNP assay. Unlike BNP, NT-proBNP is stable in EDTA plasma for 3 days at room temperature or longer at 4 degrees C. The Roche NT-proBNP is fully automated and will accommodate the testing of large numbers of clinical samples for assessing cardiac dysfunction.
Explore the source record for details and available documents.
Explore the source record for details and available documents.