Postbiopsy bleeding in a porcine model: reduction with radio-frequency ablation--preliminary results.

PURPOSE: To test a biopsy needle modified for use of radio-frequency (RF) energy to produce hemostasis after core biopsy of liver or kidney. MATERIALS AND METHODS: RF energy was applied to a partially insulated 17-gauge needle, and tip temperature was monitored with a thermocouple. Domestic Yorkshire pigs (n = 4; mean weight, 23.4 kg) were anesthetized, and their livers and kidneys were exposed. Needles were inserted 2 cm into hepatic and renal parenchyma and retracted, either with or without tract ablation to 65 degrees C, in normal tissue, animals treated with anticoagulants, and an animal with acute inferior vena caval occlusion to produce portal hypertension. Blood loss was assessed by weighing surgical sponges with blood from the puncture sites. Significant differences in blood loss between control and ablated biopsy specimens in each scenario were tested by using a Wilcoxon matched-pairs signed rank test. RESULTS: Mean blood loss for each group was as follows: In the liver, control biopsy specimens (n = 18) lost 0.30 g while ablated biopsy specimens lost 0.00044 g (P <.01), and control biopsy specimens treated with heparin (n = 26) lost 0.45 g while biopsy specimens treated with heparin and ablation lost 0.27 g (P =.03). For inferior vena caval occlusion, control biopsy specimens lost 1.23 g, while ablated biopsy specimens lost 0.00 g. In the kidney, control biopsy specimens (n = 28) lost 0.82 g, while ablated biopsy specimens lost 0.24 g (P =.01), and control biopsy specimens treated with heparin (n = 14) lost 1.04 g, while biopsy specimens treated with heparin and ablation lost 0.19 g (P =.02). CONCLUSION: Tract ablation with thermocouple-monitored RF energy decreased postprocedural hemorrhage after hepatic and renal biopsy.

Animals↗

Multiple probe radiofrequency ablation: pilot study in an animal model.

PURPOSE: Radiofrequency ablation (RFA) is becoming increasingly popular for the minimally invasive treatment of benign and malignant tumors. Currently available systems are limited to the use of a single probe because of electrical interactions between probes. The purpose of this study was to test a new prototype multiple probe generator with a built-in switching mechanism to determine if multiple zones of necrosis could be formed simultaneously without a significant penalty in terms of lesion size and procedure time. MATERIALS AND METHODS: A dual probe generator was created by modifying a commercially available system into an alternating monopolar system with an external electronic switch controlled by a temperature feedback loop. A total of 20 radiofrequency (RF) lesions (conventional single probe, n = 10; switched dual probe, n = 10) were created in the livers of six adult pigs (temperature, 100 degrees C; 10-minute ablation). Lesions were excised and examined for volume, minimum diameter, and maximum diameter. RESULTS: The time to target temperature was slightly greater for dual (3.5 minutes) versus single ablations (2.7 minutes). However, this resulted in only a 48 second (6.5%) longer total ablation time. There was no significant difference between conventional single and dual lesions for lesion volume (13.6 +/- 9.3 cm(3) versus 13.7 +/- 7.0 cm(3); P >.05), minimum diameter (1.63 +/- 0.56 cm(3) versus 1.61 +/- 0.53; P >.05) or maximum diameter (3.3 +/- 0.84 versus 3.4 +/- 0.55, P >.05). CONCLUSION: A multiple probe RFA system that can simultaneously ablate multiple areas in the liver is feasible. If multiple probe units become clinically available, large or irregularly shaped lesions could be treated more effectively than with conventional single probe units, and multiple tumors could be ablated simultaneously, thus potentially decreasing procedure time and anesthetic complications.

Animals↗

Hepatic radiofrequency ablation with internally cooled probes: effect of coolant temperature on lesion size.

Radiofrequency (RF) ablation is a minimally invasive method for treatment of primary and metastatic liver tumors. One of the currently commercially available devices employs an internally cooled 17-gauge needle probe. Within the probe, cool water is circulated during ablation, which cools tissue close to the probe resulting in larger lesions. We evaluated the effect of different cooling water temperatures on lesion size. We created a finite-element method model, simulated 12 min impedance-controlled ablation and determined temperature distribution for three water temperatures. Lesion diameters in the model were 33.8, 33.4, and 32.8 mm for water temperatures of 5 degrees C, 15 degrees C, and 25 degrees C, respectively. We solved a simplified model geometry analytically and present dependence of lesion diameter on cooling temperature. We further performed ex vivo experiments in fresh bovine liver. We created four lesions for each water temperature, with the same water temperatures as used in the finite-element method (FEM) model. Average lesion diameters were 28.3, 30, and 29.5 mm for water temperatures of 5 degrees C, 15 degrees C, and 25 degrees C, respectively. Water temperature did not have a significant effect on lesion size in the ex vivo experiments (p = 0.76), the FEM model, and the analytical solution.

Animals↗

Image-guided tumor ablation: proposal for standardization of terms and reporting criteria.

The field of image-guided tumor ablation requires standardization of terms and reporting criteria to facilitate effective communication of ideas and appropriate comparison between treatments with different technologies, such as chemical ablation (ethanol or acetic acid) and thermal therapies, such as radiofrequency, laser, microwave, ultrasound, and cryoablation. On the basis of this premise, a working committee was established with the goal of producing a proposal on such standardization. The intent of the Working Group is to provide a framework that will facilitate the clearest communication between investigators and will provide the greatest flexibility in comparisons between the many new, exciting, and emerging technologies. The members of the Working Group now propose a vehicle for reporting the various aspects of image-guided ablation therapy, including classifications of therapies and procedures, appropriate descriptors of image guidance, and terms to define imaging and pathologic findings. Methods for standardizing the reporting of follow-up findings and complications and other important aspects that require attention when reporting clinical results are addressed. It is the group's hope and intention that adherence to the recommendations of this proposal will facilitate achievement of the group's main objective: improved precision and communication in this field that lead to more accurate comparison of technologies and results and ultimately to improved patient outcomes.

Catheter Ablation↗

Hepatic microwave ablation with multiple antennae results in synergistically larger zones of coagulation necrosis.

BACKGROUND: Microwave ablation is a promising treatment for unresectable liver tumors. Unlike radiofrequency ablation, microwave ablation may be performed with multiple simultaneously active antennae. METHODS: Microwave ablation was performed in an in vivo porcine liver model by using a single antenna (n = 11) or three antennae in a triangular array, activated either sequentially (n = 11) or simultaneously (n = 13). Lesions were measured and assigned a qualitative shape score. RESULTS: Single-antenna microwave lesions had a mean volume of 7.4 +/- 3.9 cm(3), compared with 14.6 +/- 5.2 cm(3) and 43.1 +/- 4.3 cm(3) for sequential and simultaneous multiple-probe ablations, respectively (P <.001; analysis of variance). Simultaneous lesions were rounder than sequential ablations and were more effective near blood vessels. Simultaneous lesions created with probe separation of < or =1.7 cm were round and confluent, whereas clefts were present with distances >1.7 cm (P <.001). CONCLUSIONS: Microwave ablation has several theoretical advantages over currently available radiofrequency devices. Simultaneous three-probe microwave ablation lesions were three times larger than sequential lesions and nearly six times greater in volume than single-probe lesions. Additionally, simultaneous multiple-probe ablation results in qualitatively better lesions, with more uniform coagulation and better performance near blood vessels. Simultaneous multiple-probe ablation may decrease inadequate treatment of large tumors and decrease recurrence rates after tumor ablation.

Animals↗

Using a saline chaser to decrease contrast media in abdominal CT.

OBJECTIVE: The purpose of this study was to compare hepatic tumor conspicuity on CT after injection of either 150 mL of contrast material or 100 mL of contrast material plus a 50-mL saline chaser. SUBJECTS AND METHODS: We evaluated 86 hypoattenuating liver metastases in 26 patients. Patients underwent CT in two sessions separated by a mean of 85 days: one time with 150 mL of contrast material and the other time with 100 mL of contrast material followed by a 50-mL saline chaser. The order of the sessions was randomized. Contrast material was administered via power injector and matched for injection rate and delay time. Attenuation values were obtained from normal liver tissue and metastases and from the spleen, kidney, aorta, and inferior vena cava. RESULTS: The 150 mL dose of contrast material caused slightly greater liver and tumor attenuation than 100 mL of contrast material with a chaser (mean hepatic attenuation, 95.6 vs 89.8 H, respectively; p < 0.03, paired t test; mean tumor attenuation, 53.2 vs 49.1 H, respectively; r = 0.71, p = 0.09). The difference in conspicuity of liver lesions was slightly greater with 150 mL than with 100 mL with a chaser (46.8 H vs 44.2 H; r = 0.46, p = 0.08, paired t test), but was of doubtful clinical significance (2.6 H). Kidney, spleen, and vascular structures enhanced more with 150 mL than with 100 mL and a chaser. CONCLUSION: Using 100 mL of contrast material and a saline chaser did not result in a meaningful difference in liver parenchyma attenuation or lesion conspicuity compared with using 150 mL of contrast medium alone. Routine use of a chaser for abdominal CT may yield cost savings and a decreased risk of contrast nephropathy.

Adult↗

Elastographic measurement of the area and volume of thermal lesions resulting from radiofrequency ablation: pathologic correlation.

OBJECTIVE: Elastography is a promising tool for visualizing the zone of necrosis in liver tissue resulting from radiofrequency tumor ablation. Because heat-ablated tissues are stiffer than normal untreated tissue, elastography may prove useful for following up patients who undergo radiofrequency ablative therapy. We sought to report the initial evaluations of the reliability of elastography for delineating thermal lesion boundaries in liver tissue by comparing lesion dimensions determined by elastography with the findings at whole-mount pathology. MATERIALS AND METHODS: Radiofrequency ablation was performed in vitro on liver tissue specimens encased in gelatin phantoms. The imaging plane for elastography was perpendicular to the axis of the radiofrequency electrode so that the ablated region was around the center of the plane. To obtain three-dimensional visualization of thermal lesions, we reconstructed the lesions from multiple elastograms by linearly translating the elastographic scanning plane. Pathology photographs were obtained in the same image plane used for elastography by slicing through the gelatin and tissue phantom using external markers. We used digitized gross pathology photographs obtained at a specified slice thickness to compute the areas and volumes of the lesions. These measurements were then compared to the measurements obtained from the elastograms. RESULTS: In a sample of 40 thermal lesions, we obtained a correlation between in vitro elastographic and pathologic measurements of r = 0.9371 (p < 0.00001) for area estimates and r = 0.979 (p < 0.00001) for volume estimates. CONCLUSION: We found excellent correlation between the measurements of the dimensions, areas, and volumes of thermal lesions that were based on elastographic images and the measurements that were based on digitized pathologic images. When compared with digitized pathologic measurements, elastographic measurements showed a tendency to slightly underestimate both the areas and volumes of lesions. Nevertheless, elastography is a reliable technique for delineating thermal lesions resulting from radiofrequency ablation.

Animals↗

Minimally invasive approaches in management of hepatic tumors.

Traditionally, the only curative option for patients with liver tumors has been hepatic resection. Unfortunately, only 10%-20% of patients with liver tumors can undergo surgical resection due to limited hepatic reserve, high surgical risk, or unfavorable tumor location. Ablation of liver tumors is currently the main alternative to formal liver resection. Tumor cell death is achieved through a number of technologies, which may be separated into three categories: chemical (percutaneous ethanol injection), cold-based (cryotherapy), and heat-based (radiofrequency and microwave ablation or laser hyperthermia). Although long-term data are limited, ablation may be curative in some patients with a three- and five-year survival rate approaching that of resection. The main factors to success include proper patient selection, excellent diagnostic and procedural imaging, and careful post-procedure management and follow up. Long-term success following tumor ablation will be most dependent on the underlying tumor biology and the ability to achieve a negative margin. Future directions in ablation will include the use of adjunctive agents such as chemotherapeutics, further advances in energy delivery, improved imaging and lesion targeting, and continued refinements of current technology and technique.

Carcinoma, Hepatocellular↗

Three-Dimensional finite-element analyses for radio-frequency hepatic tumor ablation.

Radio-frequency (RF) hepatic ablation, offers an alternative method for the treatment of hepatic malignancies. We employed finite-element method (FEM) analysis to determine tissue temperature distribution during RF hepatic ablation. We constructed three-dimensional (3-D) thermal-electrical FEM models consisting of a four-tine RF probe, hepatic tissue, and a large blood vessel (10-mm diameter) located at different locations. We simulated our FEM analyses under temperature-controlled (90 degrees C) 8-min ablation. We also present a preliminary result from a simplified two-dimensional (2-D) FEM model that includes a bifurcated blood vessel. Lesion shapes created by the four-tine RF probe were mushroom-like, and were limited by the blood vessel. When the distance of the blood vessel was 5 mm from the nearest distal electrode 1) in the 3-D model, the maximum tissue temperature (hot spot) appeared next to electrodes A. The location of the hot spot was adjacent to another electrode 2) on the opposite side when the blood vessel was 1 mm from electrode A. The temperature distribution in the 2-D model was highly nonuniform due to the presence of the bifurcated blood vessel. Underdosed areas might be present next to the blood vessel from which the tumor can regenerate.

Catheter Ablation↗

Finite-element analysis of hepatic multiple probe radio-frequency ablation.

Radio-frequency (RF) ablation is an important means of treatment of nonresectable primary and metastatic liver tumors. RF ablation, unlike cryoablation (a method of tumor destruction that utilizes cold rather than heat), must be performed with a single probe placed serially. The ablation of any but the smallest tumor requires the use of multiple overlapping treatment zones. We evaluated the performance of a configuration incorporating two hooked probes (RITA model 30). The probes were lined up along the same axis in parallel 20 mm apart. Three different modes applied voltage to the probes. The first mode applied energy in monopolar mode (current flows from both probes to a dispersive electrode). The second mode applied the energy to the probes in bipolar mode (current flows from one probe to the other). The third method applied the energy sequentially in monopolar mode (in 2-s intervals switched between the probes). We used the finite-element method (FEM) and analyzed the electric potential profile and the temperature distribution at the end of simulation of a 12-min ablation. The alternating monopolar mode allowed precise independent control of the amount of energy deposited at each probe. The bipolar mode created the highest temperature in the area between the probes in the configuration we examined. The monopolar mode showed the worst performance since the two probes in close vicinity create a disadvantageous electric field configuration. We, thus, conclude that alternating monopolar RF ablation is superior to the other two methods.