Publications and source records attributed to Frederic H Fahey.

7 recordsLinked to original sources

Standardization and quantification of radionuclide solid gastric-emptying studies.

UNLABELLED: The purposes of this investigation were to standardize and validate a simple quantitative method for performing radionuclide solid gastric emptying that can be used for any dual-head gamma-camera and to establish reference values. METHODS: After eating a solid meal (egg sandwich) labeled with a radionuclide, 20 healthy volunteers (9 male, 11 female) underwent a 90-min gastric-emptying study performed with a triple-head gamma-camera. Two sets of 3 simultaneous projections were acquired sequentially for 30 s each: anterior, right posterior oblique (RPO), left posterior oblique (LPO), posterior, left anterior oblique (LAO), and right anterior oblique (RAO), and this sequence was repeated continuously for 90 min. Time-activity curves were generated using a gastric region of interest for each of the views as well as the conjugate-view geometric mean (GM) data for the anterior/posterior, LAO/RPO, and RAO/LPO combinations. Quantitative parameters were determined: percentage gastric emptying (%GE) at 90 min, half-time (min) based on an exponential fit, and clearance rate (%/min) based on a linear fit. Reference values were determined on the basis of a 95% confidence interval of the t distribution. The results were statistically analyzed and compared. RESULTS: The %GE reference values were greater for the anterior/posterior GM (>or=33%) than for the LAO (>or=31%) and anterior (>or=30%) GMs. The 3 %GE GM methods, the 3 exponential-fit GM methods, and the 3 linear-fit GM methods had high correlation coefficients (r >or= 0.874), and with only a single exception, there was no statistical difference among them. The LAO method and LAO/RPO GM mean method correlated strongly (r = 0.900) and had similar mean values (52% vs. 51%) and reference values (29% vs. 30%). All 3 methods of GM quantification also correlated strongly, and there was no significant difference among them. CONCLUSION: We have described and validated a simple method for radionuclide solid gastric emptying that can be used with a dual-head gamma-camera. We recommend the anterior/posterior GM method and have established reference values (>or=33%).

Adult↗

Instrumentation in positron emission tomography.

The past 40 years have seen PET scanning evolve from a tool that was used predominantly for research to a valued clinical, imaging modality. Current PET scanners must perform high quality, whole-body, as well as brain, PET. There are several levels of PET devices that range from the dedicated, high-end scanners down to the hybrid PET-SPECT systems that offer varying levels of performance. The incorporation of PET into single, hybrid, multi-modality units that can provide functional and anatomic information is becoming extremely popular. Several manufacturers now provide hybrid PET-CT scanners. There is also a growing interest in dedicated devices for specific applications, such as high-resolution scanners for imaging small animals.

Animals↗

Application of TACT to the evaluation of total joint arthroplasty.

Three-dimensional imaging may be valuable in the evaluation of total joint arthroplasty. The partial-volume effect and streak artifacts from the metallic components of these devices limit the applicability of computed tomography (CT) to this application. Tuned-aperture computed tomography (TACT) is a tomographic approach that has been successfully used in other medical applications. In TACT, the acquisition geometry is inferred from the localization of fiducial markers in a series of projection images. The flexibility and robustness of TACT, as well as the fact that through an appropriate choice of reconstruction algorithms it can suppress streak artifacts, potentially makes it an appropriate approach for evaluating total joint arthroplasty. A simple computer-simulated model of a total knee replacement (TKR) was generated and used to evaluate the accuracy and artifacts associated with three-dimensional (3-D) renderings produced using TACT. A knee specimen from a cadaver that had received a TKR was used to investigate further the potential of TACT for this application. In both tests, TACT provided high-quality 3-D representations of the object. Both simple back-projection and minimum pixel back-projection were used to reconstruct the data. Minimum pixel back-projection provided high-contrast images that appeared to be relatively free of tomosynthetic artifacts. In summary, the potential of TACT in the evaluation of total joint arthroplasty was demonstrated. Future investigations will study TACT's ability to quantify the spatial relationship between the metallic components of these devices as well as TACT's ability to identify bony changes of diagnostic consequence.

Algorithms↗

Dexmedetomidine-induced sedation in volunteers decreases regional and global cerebral blood flow.

UNLABELLED: Dexmedetomidine is a selective alpha(2)-agonist approved for sedation of critically ill patients. There is little information on the effects of dexmedetomidine on cerebral blood flow (CBF) or intracranial hemodynamics, despite considerable other pharmacodynamic data. We hypothesized that therapeutic doses of dexmedetomidine would decrease CBF. Therefore, nine supine volunteers, aged 24-48 yr, were infused with a 1 micro g/kg IV loading dose of dexmedetomidine, followed by an infusion of 0.2 micro g. kg(-1). h(-1) (LOW DEX) and 0.6 micro g. kg(-1). h(-1) (HIGH DEX). Hemodynamic and CBF (via positron emission tomography) measurements were determined at each experimental time point. Dexmedetomidine decreased both cardiac output and heart rate during and 30 min after drug administration. Blood pressure decreased from 12% to 16% during and after the dexmedetomidine administration. Global CBF was decreased significantly from baseline (91 mL. 100 g(-1). min(-1) [95% confidence interval, 72-114] to 64 mL. 100 g(-1). min(-1) [51-81] LOW DEX and 61 mL. 100 g(-1). min(-1) [48-76] HIGH DEX). This decrease in CBF remained constant for at least 30 min after the dexmedetomidine infusion was discontinued, despite the plasma dexmedetomidine concentration decreasing 40% during this same time period (628 pg/mL [524-732] to 380 pg/mL [253-507]). IMPLICATIONS: Dexmedetomidine-induced sedation decreased cerebral blood flow (CBF) by congruent with 33%, which could be due to direct alpha(2)-receptor cerebral smooth muscle vasoconstriction or to compensatory CBF changes caused by dexmedetomidine-induced decreases in the cerebral metabolic rate.

Adrenergic alpha-Agonists↗

Angular disparity in ETACT scintimammography.

Emission tuned aperture computed tomography (ETACT) has been previously shown to have the potential for the detection of small tumors (<1 cm) in scintimammography. However, the optimal approach to the application of ETACT in the clinic has yet to be determined. Therefore, we sought to determine the effect of the angular disparity between the ETACT projections on image quality through the use of a computer simulation. A small, spherical tumor of variable size (5, 7.5 or 10 mm) was placed at the center of a hemispherical breast (15 cm diameter). The tumor to nontumor ratio was either 5:1 or 10:1. The detector was modeled to be a gamma camera fitted with a 4-mm-diam pinhole collimator. The pinhole-to-detector and the pinhole-to-tumor distances were 25 and 15 cm, respectively. A ray tracing technique was used to generate three sets of projections (10 degrees, 15 degrees, and 20 degrees, angular disparity). These data were blurred to a resolution consistent with the 4 mm pinhole. The TACT reconstruction method was used to reconstruct these three image sets. The tumor contrast and the axial spatial resolution was measured. Smaller angular disparity led to an improvement in image contrast but at a cost of degraded axial spatial resolution. The improvement in contrast is due to a slight improvement in the in-plane spatial resolution. Since improved contrast should lead to better tumor detectability, smaller angular disparity should be used. However, the difference in contrast between 10 degrees and 15 degrees was very slight and therefore a reasonable clinical choice for angular disparity is 15 degrees.

Breast↗

Data acquisition in PET imaging.

Data acquisition is substantially different in PET than it is in planar nuclear medicine and SPECT. There is an entirely different set of definitions and considerations. The objective of this paper is to provide the reader with the terminology and understanding of how PET data are acquired and organized as well as the issues involved in choosing one approach over another. Sinograms and projection views will be presented as methods of storing and viewing raw PET data. Different approaches to increase axial sampling while maintaining a sufficient number of counts for each reconstructed slice are discussed, as well as the use of sinogram compression or "mashing" to reduce the storage requirements of raw PET data. The differences between 2-dimensional (2D) and 3-dimensional (3D) PET and how storage of raw 3D data may differ from that of 2D data are described. The concept of "Michelograms" as a means of displaying the nature of the axial sampling in both 2D and 3D PET is discussed. After reading this paper, the reader will be able to describe 2 methods used to store and display raw PET data and compare them with methods used in SPECT. The reader will be able to define the terms "span" and "maximum ring difference" and describe how they relate to the axial sampling in 2D and 3D PET. The reader will also be able to list 3 ways in which 3D PET differs from 2D PET.

Algorithms↗

Evaluation of the quantitative capability of a high-resolution positron emission tomography scanner for small animal imaging.

OBJECTIVE: The quantitative capability of a positron emission tomography scanner for small animal imaging was evaluated in this study. METHODS: The microPET P4 (Concorde Microsystems, Knoxville, TN) scanner's capability for dynamic imaging and corrections for radioactive decay, dead time, and attenuation were evaluated. Rat brain and heart studies with and without attenuation correction were compared. A calibration approach to convert the data to nanocuries per milliliter was implemented. Calibration factors were determined using calibration phantoms of 2 sizes with and without attenuation correction. Quantitation was validated using the MiniPhantom (Data Spectrum, Chapel Hill, NC) with hot features (5:1 ratio) of different sizes (4, 6.4, 8, 13, and 16 mm). RESULTS: The microPET P4 scanner's ability to acquire dynamic studies and to correct for decay, dead time, and attenuation was demonstrated. The microPET P4 scanner provided accurate quantitation to within 6% for features larger than 10 mm. Sixty percent of object contrast was retained for features as small as 4 mm. CONCLUSIONS: The microPET P4 scanner can provide accurate quantitation.

Animals↗