PubMed Health⌕ Search

Biomedical subjects

Freek Ariese

Publications and source records attributed to Freek Ariese.

At least 19 recordsLinked to original sources

Strong overtones and combination bands in ultraviolet resonance Raman spectroscopy.

Ultraviolet resonance Raman spectroscopy is carried out using a continuous wave frequency-doubled argon ion laser operated at 229, 244, and 257 nm in order to characterize the overtones and combination bands for several classes of organic compounds in liquid solutions. Contrary to what is generally anticipated, for molecules such as pyrene and anthracene, strong overtones and combination bands can show up; it is demonstrated that their intensity depends critically on the applied laser wavelength. If the excitation wavelength corresponds with a purely electronic transition--this applies to a good approximation for 244-nm excitation in the case of pyrene and for 257-nm excitation in the case of anthracene--mostly fundamental vibrations (up to 1700 cm(-1)) are observed. Overtones and combination bands are detected but are rather weak. However, if the laser overlaps with the vibronic region--as holds for 229- and 257-nm excitation for pyrene and 244-nm excitation for anthracene--very strong bands are found in the region 1700-3400 cm(-1). As illustrated for pyrene at 257 nm, all these bands can be assigned to first overtones or binary combinations of fundamental vibrations. Their intensity distribution can roughly be simulated by multiplying the relative intensities of the fundamental bands. Significant bands can also be found in the region 3400-5000 cm(-1), corresponding with second overtones and ternary combinations. It is shown that these findings are not restricted to planar and rigid molecules with high symmetry. Substituted pyrenes exhibit similar effects, and relatively strong overtones are also observed for adenosine monophosphate and for abietic acid. The reasons for these observations are discussed, as well as the potential applicability for analytical purposes.

Journal Article↗

Analytical separation and detection methods for flavonoids.

Flavonoids receive considerable attention in the literature, specifically because of their biological and physiological importance. This review focuses on separation and detection methods for flavonoids and their application to plants, food, drinks and biological fluids. The topics that will be discussed are sample treatment, column liquid chromatography (LC), but also methods such as gas chromatography (GC), capillary electrophoresis (CE) and thin-layer chromatography (TLC), various detection methods and structural characterization. Because of the increasing interest in structure elucidation of flavonoids, special attention will be devoted to the use of tandem-mass spectrometric (MS/MS) techniques for the characterization of several important sub-classes, and to the potential of combined diode-array UV (DAD UV), tandem-MS and nuclear magnetic resonance (NMR) detection for unambiguous identification. Emphasis will be on recent developments and trends.

Beverages↗

Two fish bile reference materials certified for PAH metabolites.

Environmental pollution with polycyclic aromatic hydrocarbons (PAHs) from pyrogenic or petrochemical sources is a matter of concern in many aquatic ecosystems. For field monitoring purposes, PAH metabolite levels in fish bile samples can be used as biomarkers of exposure, but previously there were no reference materials for analytical method validation or quality control. In this paper we describe the preparation and certification of two fish bile materials. BCR 720 is a pure bile material from sediment-exposed flounder (Platichthys flesus) and BCR 721 is a pure bile material from oil-exposed plaice (Pleuronectes platessa). Homogeneity and stability tests were carried out and a group of 12 expert laboratories was assembled for the certification measurements. The methods applied were liquid chromatography with fluorescence detection or gas chromatography with mass spectrometric detection. In BCR 720 three PAH metabolites were certified: 1-hydroxyphenanthrene, 1-hydroxypyrene and 3-hydroxybenzo[a]pyrene. In BCR 721 1-hydroxypyrene was certified. The fourth target compound, 2-hydroxynaphthalene, could not be certified, but the results obtained are listed. The major findings from earlier feasibility studies and recommendations for the optimal use of the reference materials are also included.

Animals↗

Coupling of size-exclusion chromatography to a continuous assay for subtilisin using a fluorescence resonance energy transfer peptide substrate: testing of two standard inhibitors.

Liquid chromatography (LC) was coupled on-line to a homogeneous continuous-flow protease assay using fluorescence resonance energy transfer (FRET) as a readout for the screening of inhibitors of an enzyme (e.g., Subtilisin Carlsberg). The inhibitors aprotinin (a protein of approximately 6500 g/mol) and 4-(2-aminoethyl)benzenesulfonyl fluoride hydrochloride (AEBSF, 240 g/mol) were mixed with other, non-active compounds and separated on a size-exclusion chromatography column. After the separation, the analytes were eluted to the postcolumn reactor unit where the enzyme solution and subsequently the FRET peptide substrate were added; by measuring the fluorescence intensity the degree of inhibition was monitored on-line. As expected, only the two inhibitors caused a change in the FRET response. Detection limits for aprotinin were 5.8 microM in the flow injection analysis (FIA) mode and 12 microM in the on-line LC mode. System validation was performed by determining IC50 values for aprotinin for the FIA mode (19 microM) and the on-line mode (22 microM). These IC50 values were in line with the value determined in batch experiments (25 microM). With this system, chemical information (i.e., chromatographic retention time) and biological information (i.e., enzyme inhibition) can be combined to characterize mixtures.

Aprotinin↗

Combined theoretical and experimental deep-UV resonance raman studies of substituted pyrenes.

The results of time-dependent density functional theory (TDDFT) calculations of resonance Raman intensities are combined with experimental deep-ultraviolet resonance Raman measurements at a single wavelength, i.e., 244 nm, in order to test the possibility to distinguish several very similar compounds. Pyrene and three of its substituted derivatives, in which a single hydrogen atom has been replaced by a halogen atom, are compared. The fixed 244 nm excitation wavelength overlapped with the same electronic transition of the four pyrenes. Ground-state calculations using the BP86 exchange-correlation functional were used to predict the Raman frequencies, whereas excited-state calculations have been carried out employing the "statistical averaging of (model) orbital potentials" (SAOP) potential within a linear-response TDDFT framework in combination with the short-time approximation of resonance Raman intensities. In view of the simplistic theoretical approach, we find a surprisingly good agreement between the simulated and measured resonance Raman spectra of pyrene and its substituted analogues in terms of frequencies and intensities, which shows that the calculations can be used reliably to interpret the experimental spectra. With this combined information, it is possible to find criteria to distinguish the compounds under investigation, although many features of their vibrational spectra are similar.

Journal Article↗

Changed isoflavone levels in red clover (Trifolium pratense L.) leaves with disturbed root nodulation in response to waterlogging.

The effect of disturbed root nodulation on the quantitative and qualitative composition of the main isoflavonoid glucoside malonates, glucosides, and aglycones in the leaves of Trifolium pratense L. grown under waterlogging conditions was investigated. Isoflavonoids are involved in the regulation of root nodule activity and the establishment of the mycorrhizal association. Isoflavonoid determination was performed using reversed-phase liquid chromatography coupled to mass spectrometric and UV absorbance detection. In response to waterlogging, the concentrations of biochanin A and biochanin A-7-O-glucoside malonate, biochanin A-7-O-glucoside, and genistein-7-O-glucoside in the leaves increased two- to threefold after a lag period of 3 wk because of disturbed root nodulation. The other isoflavones detected formononetin, formononetin-7-O-glucoside malonate, and formononetin-7-O-glucoside-did not show any significant changes related to waterlogging. After restoring normal soil water conditions, the concentrations of biochanin A and its glucoside and glucoside-malonate rapidly returned to the initial values, whereas the concentration of genistein-7-O-glucoside remained high.

Adaptation, Physiological↗

Identification and quantification of the depurinating DNA adducts formed in mouse skin treated with dibenzo[a,l]pyrene (DB[a,l]P) or its metabolites and in rat mammary gland treated with DB[a,l]P.

Dibenzo[a,l]pyrene (DB[a,l]P) is the most potent carcinogenic polycyclic aromatic hydrocarbon and has been identified in the environment. Comparative tumorigenicity studies in mouse skin and rat mammary gland indicate that DB[a,l]P is slightly more potent than DB[a,l]P-11,12-dihydrodiol and much more potent than (+/-)-syn-DB[a,l]P-11,12-dihydrodiol-13,14-epoxide {(+/-)-syn-DB[a,l]PDE} and (+/-)-anti-DB[a,l]PDE. We report here the identification and quantification of the depurinating adducts formed in mouse skin treated with DB[a,l]P, DB[a,l]P-11,12-dihydrodiol, (+/-)-syn-DB[a,l]PDE, or (+/-)-anti-DB[a,l]PDE and rat mammary gland treated with DB[a,l]P. The biologically formed adducts were compared with standard adducts by their retention times on HPLC and their spectra obtained by fluorescence line-narrowing spectroscopy at low temperature. In mouse skin treated with DB[a,l]P, depurinating adducts comprised 99% of the total adducts. Most of the depurinating adducts were formed by one-electron oxidation, with 63% at Ade and 12% at Gua. The remainder were formed by the diol epoxide, with 18% at Ade and 6% at Gua. When mouse skin was treated with DB[a,l]P-11,12-dihydrodiol, depurinating adducts comprised 80% of the total, and the predominant one was with Ade (69%). Treatment of skin with (+/-)-syn-DB[a,l]PDE resulted in 32% depurinating adducts, primarily at Ade (25%), whereas treatment with (+/-)-anti-DB[a,l]PDE produced 97% stable adducts. The formation of depurinating adducts following treatment of rat mammary gland with DB[a,l]P resulted in approximately 98% depurinating adducts, with the major adducts formed by one-electron oxidation. Only one depurinating diol epoxide adduct was formed. Tumorigenicity, mutations, and DNA adduct data suggest that depurinating Ade adducts play a major role in the initiation of tumors by DB[a,l]P.

Animals↗

The chemical interaction between the estrogen receptor and monohydroxybenzo[a]pyrene derivatives studied by fluorescence line-narrowing spectroscopy.

A novel approach is presented for studying the chemical interaction between receptor binding sites and ligands. Monohydroxylated polyaromatic compounds were found to be environmentally sensitive ligands when applying a special mode of fluorescence: fluorescence line-narrowing spectroscopy (FLNS). With this technique, solvent dependencies and ligand-receptor interactions can be studied in great detail, due to the high spectral resolution and the fact that at cryogenic temperatures (4 K), no solvent reorientation effects complicate the interpretation. The FLN spectrum of a ligand bound to the receptor is compared to the spectra of the free ligand in solvent mixtures that mimic the functionalities present within the receptor's binding site. It is shown that for the well-known estrogen receptor (ER), the orientations of two xenoestrogenic ligands 3- and 9-hydroxybenzo[a]pyrene (3- and 9-OH-BaP) can be determined. The FLN results clearly indicate that an H-bond accepted by HIS524 plays a major role in the binding of these ligands to the ER. Furthermore, the spectra indicated a pi-pi stacking aromatic interaction for 9-OH-BaP with PHE404. These results are in line with molecular modeling studies published earlier.

Benzo(a)pyrene↗

A flow injection kinase assay system based on time-resolved fluorescence resonance energy-transfer detection in the millisecond range.

A flow injection analysis (FIA) system for biochemical assays using time-resolved fluorescence resonance energy transfer (TR-FRET) in the millisecond time scale was developed. As a model system, we studied a kinase assay, measuring the phosphorylation of poly(GT)-biotin (substrate) by a receptor tyrosine kinase (epidermal growth factor receptor). A streptavidin labeled with XL665 (SA-XL665)-the acceptor-was coupled to the biotin moiety, and an antiphosphotyrosine antibody labeled with europium cryptate (Ab-EuK)-the donor-was coupled to the phosphorylated tyrosine group(s). Long-lived FRET can only occur if the substrate is successfully phosphorylated. For the time-resolved detection of such long-lived luminescence phenomena in a flow system, the repetition rate of the excitation source plays a crucial role. Good results were obtained for a small-sized commercially available quadrupled Nd:YAG laser emitting at 266 nm with a repetition rate of 7.8 kHz and a pulse width of 0.3 ns. The long-lived emissions of the donor at 625 nm and that of the acceptor at 665 nm were monitored simultaneously with two photomultipliers, using a delay time of 50 micros and a gate time of 75 micros to exclude background fluorescence interferences. In the FIA experiments, the Ab-EuK concentration was 6 nM and the substrate concentration and SA-XL665 concentrations were 7 nM. By monitoring the intensity changes at 625 and 665 nm, the inhibition of tyrosine kinase by tyrphostin AG1478 was studied and an IC(50) value of 5.1 +/- 0.4 nM obtained.

Binding Sites↗

Probing the interaction of benzo[a]pyrene adducts and metabolites with monoclonal antibodies using fluorescence line-narrowing spectroscopy.

A new approach for studying antibody-antigen interactions of DNA adducts and metabolites of polycyclic aromatic hydrocarbons (PAHs) is demonstrated in which fluorescence line-narrowing spectroscopy (FLNS) is used. It is based on the fact that in an FLN spectrum the relative intensities of the line-narrowed bands (that correspond to the excited-state vibrations) are, in general, strongly dependent on the local environment of the fluorophore. Information on the nature of the interactions can be obtained by comparing the FLN spectra of the antigen-antibody complexes to the spectra of the antigen in different types of solvents (H-bonding, aprotic, and pi-electron-containing solvent molecules) recorded under the same conditions. The antigens used were the DNA adduct 7-(benzo[a]pyren-6-yl)guanine (BP-6-N7Gua) and the metabolite (+)-trans-anti-7,8,9,10-benzo[a]pyrenetetrol (BP-tetrol) of benzo[a]pyrene; two monoclonal antibodies (MAbs) have been developed to selectively bind these compounds. It is shown that, for BP-tetrol, H-bonding solvents have a pronounced effect on the FLN spectra. The presence of pi electrons in the solvent molecules results in relatively small but still significant changes in the spectra. When BP-tetrol is bound to its MAb, however, neither of these effects is observed; its spectrum is very similar to the one obtained with an aprotic solvent, methylcyclohexane. Therefore, we can conclude that this MAb has an internal binding site in which the interaction with BP-tetrol is of a hydrophobic character. For BP-6-N7Gua, however, there is a strong effect of the presence of pi electrons in the solvent molecules. The FLN spectrum of this antigen bound to its MAb is very similar to its spectrum in acetone, indicating that pi-pi interactions play an important role in the binding.

Antibodies, Monoclonal↗

Quenched phosphorescence as a detection method in capillary electrophoretic chiral separations. Monitoring the stereoselective biodegradation of camphorquinone by yeast.

Quenched phosphorescence detection of camphorquinone in cyclodextrin-based electrokinetic chromatography provides very favorable detection limits, i.e., 7 x 10(-)(7) M, 3 orders of magnitude lower than conventional UV absorption detection at 200 nm. The detection is based on the dynamic quenching by the analyte of the strong phosphorescence emission of brominated naphthalenesulfonate, under deoxygenated buffer solution conditions. This approach has been used to detect (1S)-(+)- and (1R)-(-)-camphorquinone after enantiomeric separation by CE. Although the use of the negatively charged carboxymethyl beta-cyclodextrin (CM-beta-CD) alone was not successful, the addition of a second, neutral cyclodextrin, alpha-CD, provided an adequate enantiomeric separation of camphorquinone. Using 25 mM borate buffer (pH 8.5) with 10 mM CM-beta-CD and 20 mM alpha-CD (applied voltage 20 kV, ambient temperature), the enantiomeric separation was performed in approximately 14 min. The chiral method was applied to monitor the stereoselectivity of the biotransformation of a racemic mixture of camphorquinone by yeast. It was found that the enantiomeric ratio calculated from the peak areas in the electropherogram (RSD = 5%) after 24 h of incubation decreased from 0.92 for the control solution (culture medium without yeast) to 0.24 for the culture medium; a similar ratio of 0.25 was observed for cell extract solutions. Therefore, racemic camphorquinone is enantioselectively degraded by yeast, the biodegradation of (1S)-(+)-camphorquinone being faster than that of the (1R)-(-)-enantiomer.

Bromine↗

Liquid chromatography coupled to nuclear magnetic resonance spectroscopy for the identification of isoflavone glucoside malonates in T. pratense L. leaves.

Previous studies revealed that the main isoflavones in extracts of leaves of T. pratense L. are biochanin A and formononetin, their 7-O-glucosides, and two glucoside malonate isomers of each of them. Since LC-MS(/MS) did not provide sufficient information to distinguish the glucoside malonate isomers, in the present paper LC-NMR as well as off-line two-dimensional NMR were used to obtain further structural information. Matrix solid-phase dispersion (MSPD) was applied to obtain sufficiently high analyte concentrations to perform LC-NMR. Stop-flow reversed-phase LC-NMR was performed using a gradient of deuterated water and deuterated acetonitrile. Offline COSY and NOESY experiments were carried out to determine the positions of the glucose moiety on the flavonoid aglycone, and of the malonate moiety on the glucose. Based on the fragmentation patterns in MS/MS and the NMR spectra, the two formononetin glucoside malonate isomers were identified as 7-O-beta-D-glucoside 6"-O-malonate and 7-O-beta-D-glucoside 4"-O-malonate; i.e. they only differ in the substitution position of the malonate group on the glucoside ring. The biochanin A glucoside malonate isomers, however, have quite different structures. The main and later eluting isomer is biochanin A 7-O-beta-D-glucoside 6"-O-malonate, and the minor and earlier eluting isomer is 5-hydroxy-7-methoxyisoflavone 4'-O-beta-D-glucoside 4"-O-malonate: the positions of the methoxy group and the glucoside 6"-O-malonate group on the flavonoid skeleton are interchanged.

Chromatography, Liquid↗

PAH biotransformation in terrestrial invertebrates--a new phase II metabolite in isopods and springtails.

Soil-living invertebrates are exposed to high concentrations of contaminants accumulating in dead organic matter, such as polycyclic aromatic hydrocarbons (PAHs). The capacity for PAH biotransformation is not equally developed in all invertebrates. In this paper, we compare three species of invertebrates, Porcellio scaber (Isopoda), Eisenia andrei (Lumbricidae) and Folsomia candida (Collembola), for the metabolites formed upon exposure to pyrene. Metabolic products of pyrene biotransformation in extracts from whole animals or isopod hepatopancreas were compared to those found in fish bile (flounder and plaice). An optimized HPLC method was used with fluorescence detection; excitation/emission spectra were compared to reference samples of 1-hydroxypyrene and enzymatically synthesized conjugates. Enzymatic hydrolysis after fractionation was used to demonstrate that the conjugates originated from 1-hydroxypyrene. All three invertebrates were able to oxidize pyrene to 1-hydroxypyrene, however, isopods and collembolans stood out as more efficient metabolizers compared to earthworms. In contrast to fish, none of the invertebrates produced pyrene-1-glucuronide as a phase II conjugate. Both Collembola and Isopoda produced significant amounts of pyrene-1-glucoside, whereas isopods also produced pyrene-1-sulfate. A third, previously unknown, conjugate was found in both isopods and springtails, and was analysed further using electrospray and atmospheric pressure chemical ionisation mass spectrometry. Based on the obtained mass spectra, a new conjugate is proposed: pyrene-1-O-(6"-O-malonyl)glucoside. The use of glucose-malonate as a conjugant in animal phase II biotransformation has not been described before, but is understandable in the microenvironment of soil-living invertebrates. In the earthworm, three other pyrene metabolites were observed, none of which was shared with the arthropods, although two were conjugates of 1-hydroxypyrene. Our study illustrates the great variety of the still unexplored metabolic diversity of invertebrate xenobiotic metabolism.

Animals↗

Monitoring and evaluation of the environmental dissipation of the marine antifoulant 4,5-dichloro-2-n-octyl-4-isothiazolin-3-one (DCOIT) in a Danish Harbor.

The concentration of marine antifoulant 4,5-dichloro-2-n-octyl-4-isothiazolin-3-one (DCOIT; the active ingredient in Sea-Nine 211 Antifouling Agent) leaching into a Danish Harbor from two painted ships was quantitated at varying distances from the ships. Sediment and suspended particulate matter were also analyzed for DCOIT. Water samples were concentrated on-site using C-18 solid phase extraction and subsequently analyzed by gas chromatography-tandem mass spectrometry. A strong decline in DCOIT water concentration as a function of distance from the ships was observed. The highest concentration (maximum 283 ng/l) was measured in the immediate vicinity of the ships and the concentration declined rapidly to less than the limit of detection (5 ng/l) at 400 m from the ships' surfaces. The measured decline curve was compared to that calculated using a one-dimensional model (ECoS). The comparison indicates that the primary mechanism of dissipation of DCOIT is not dilution resulting from dispersion but degradation with a rate constant in the order of 1 h(-1). Thus the field results correlate with the earlier microcosm studies demonstrating that DCOIT biodegrades rapidly in a marine environment.

Biodegradation, Environmental↗

Flavonoids in Leguminosae: analysis of extracts of T. pratense L., T. dubium L., T. repens L., and L. corniculatus L. leaves using liquid chromatography with UV, mass spectrometric and fluorescence detection.

Reversed-phase LC on C-18 bonded silica with a methanol-ammonium formate gradient was used to determine the main flavonoids in leaves of four species of the Leguminosae family. The detection modes were diode-array UV absorbance, fluorescence, and (tandem) mass spectrometry. LC-UV was used for a general screening, sub-classification, and the calculation of total flavonoid contents. LC-FLU was included to identify isoflavones on the basis of their native fluorescence. Most structural information regarding aglycons, sugar moieties, and acidic groups was derived from LC-MS in both the full-scan and extracted-ion mode, using negative-ion atmospheric pressure chemical ionization. MS/MS did not provide much additional information, because the same fragments were observed as in full-scan MS. In T. pratense and T. repens, the main constituents were flavonoid glucoside-(di)malonates, while T. dubium and L. corniculatus mainly contained flavonoid (di)glycosides. Satellite sets comprising an aglycon, the glucoside and glucoside-malonates or -acetates, were abundantly present only in T. pratense. Generally speaking, the main aglycons and sugars in the four plant species are surprisingly different. In addition, while the results for T. pratense are similar to those reported in the literature, there is little agreement in the case of the other species. Finally, total flavonoid contents ranged from 50-65 mg/g for L. corniculatus and T. dubium, to 15 mg/g for T. pratense and only 1 mg/g for T. repens.

Chromatography, High Pressure Liquid↗

Capillary electrophoresis coupled on-line with ultraviolet resonance Raman spectroscopy.

Capillary electrophoresis (CE) and resonance Raman spectroscopy (RRS) with excitation in the deep ultraviolet (UV) region (lambda(ex): 244 or 257 nm) were coupled on-line. The potential of this hyphenated technique, denoted as CE-UV-RRS, for analyte confirmation/identification purposes was explored with aromatic sulfonic acids and nucleotides as test compounds. Good-quality UV-RRS spectra could be recorded on-the-fly. Identification limits for the nucleotides were in the 10-125 microg/mL range. The RRS spectra showed sufficient characteristic features to enable analyte confirmation. In addition, the identification power of UV-RRS was studied with substituted pyrenes as model compounds. The compounds were distinguishable on the basis of their RRS spectra at 244 nm.

Journal Article↗

Liquid chromatography with atmospheric pressure chemical ionization and electrospray ionization mass spectrometry of flavonoids with triple-quadrupole and ion-trap instruments.

With 15 flavonoids as test compounds, the analytical performance of four modes of LC-MS, multiple MS (MSn) and tandem MS operation (atmospheric pressure chemical ionization (APCI), electrospray ionization, positive and negative ionization) was compared for two mass spectrometers, a triple-quadrupole and an ion-trap instrument. Two organic modifiers, methanol and acetonitrile, and two buffers, ammonium acetate and ammonium formate, were used. In general, the use of APCI in the negative ion mode gave the best response, with the signal intensities and the mass-spectral characteristics not differing significantly between the two instruments. The best results were obtained when methanol-ammonium formate (pH 4.0) was used as LC eluent. Under optimum conditions full-scan limits of detection of 0.1-30 mg/l were achieved in the negative APCI mode. Here it needs to be emphasized that up to 2-order response differences were found both between analytes and between modes of ionization. This implies that one should be very cautious when interpreting data on the screening of real-life samples. The main fragmentations observed in the MSn spectra on the ion-trap, or the tandem MS spectra on the triple-quadrupole were generally the same. The advantage of the former approach is the added possibility to ascertain precursor-->product ion relationships.

Atmospheric Pressure↗

Laser-induced quenched phosphorescence detection in capillary electrophoresis.

The feasibility of laser-based excitation for quenched phosphorescence detection in capillary electrophoresis (CE) was explored for the first time by using a small-size, quadrupled Nd-YAG laser emitting 266 nm pulses (duration, 0.4 ns) at a repetition rate of 7.8 kHz. To provide a continuous phosphorescence background, the phosphorophore 1-bromo-4-naphthalene sulfonic acid (BrNS) was added to the separation buffer. Both experiments and theory show that in laser-induced phosphorescence (LIP) - in contrast with lamp-excited phosphorescence - one normally deals with such high triplet-state phosphorophore concentrations that triplet-triplet annihilation is the major deactivation pathway. This results in a lower quantum yield of the analyte-induced bimolecular quenching interaction and, thus, the observed quenching signal. The situation can be improved by using a cylindrical lens for excitation in order to reduce the irradiance. In this case limits of detection (LODs) similar to those obtained using lamp excitation (1x10(-8) M) were achieved, while the width of the detection window was reduced from about 4 mm to 1 mm. Even under exclusion of triplet-triplet annihilation, i.e., under conditions of low irradiance, for our setup the quenching yields in LIP were smaller than in lamp-based phosphorescence detection. This is due to the repetition rate of the laser (7.8 kHz), which is too high in view of the phosphorescence lifetime (ca. 300 micros at low irradiance). Theory shows that this disadvantageous effect will be fully eliminated if the repetition rate is decreased to 1 kHz.

Electrons↗