An instrumented implant for vertebral body replacement that measures loads in the anterior spinal column.

Realistic loads on a spinal implant are required among others for optimization of implant design and preclinical testing. In addition, such data may help to choose the optimal physiotherapy program for patients with such an implant and to evaluate the efficacy of aids like braces or crutches. Presently, no implant is available that can measure loads in the anterior spinal column during activities of daily life. Therefore, an implant instrumented for in vivo load measurement was developed for vertebral body replacement. The aim of this paper is to describe in detail a telemeterized implant that measures forces and moments acting on it. Six load sensors, a nine-channel telemetry unit and a coil for inductive power supply of the electronic circuits were integrated into a modified vertebral body replacement (Synex). The instrumented part of the implant is hermetically sealed. Patients are videotaped during measurements, and implant loads are displayed on and off line. The average accuracy of load measurement is better than 2% for force and 5% for moment components with reference to the maximum value of 3000 N and 20 Nm, respectively. The measuring implant described here will provide additional information on spinal loads.

Equipment Design↗

Loads on an internal spinal fixation device during physical therapy.

BACKGROUND AND PURPOSE: Modified internal spinal fixation devices allow the measurement of the forces and moments acting on the implants. The aim of this study was to measure the loads on internal fixation devices for selected body positions and movements during physical therapy. SUBJECTS AND METHODS: Loads on an internal spinal fixation device were measured in 10 patients with degenerative instability or compression fractures using a telemeterized implant. RESULTS: Relatively low implant loads were found in the recumbent body positions. Most exercises performed in a lying position caused implant loads less than that measured for standing and are therefore not likely to increase the risk of screw breakage. Fixation device loads were lower for sitting relaxed than for standing. The highest implant loads (128% of the value for standing) were measured during walking. Standing up, sitting down, and lateral bending and axial rotation of the upper body while standing led to fixation device loads between 111% and 120% related to the value for standing. Even higher fixation device loads were measured for ventral flexion and extension of the upper body while standing. Kneeling on hands and knees, and flexing and extending the back in this position, caused implant loads that were lower than for standing. DISCUSSION AND CONCLUSION: Standing up, sitting down, and lateral bending and axial rotation of the upper body while standing may slightly increase the risk of pedicle screw breakage, whereas ventral flexion and extension of the upper body while standing may increase this risk considerably if the region bridged by the implant is distracted (the distance between upper and lower screws was increased) during surgery. However, walking is the exercise that plays the major role concerning pedicle screw breakage because it causes the highest bending moments of all exercises studied and it loads the fixation devices most frequently.

Adult↗