PubMed Health⌕ Search

Biomedical subjects

Friedrich D Knollmann

Publications and source records attributed to Friedrich D Knollmann.

6 recordsLinked to original sources

Assessment of coronary artery stent patency by electron-beam CT.

Following coronary angioplasty and stent implantation, restenosis remains common and its outcome difficult to predict. We set out to determine the diagnostic accuracy of electron-beam computed tomography (EBCT) for the non-invasive detection of stent obstruction. In a prospective, blinded investigation, we included 152 coronary artery segments in 117 patients treated with a stent implant. All segments were evaluated by a dynamic EBCT study that depicted contrast bolus passage distal to the stent and a CT angiographic study of the entire coronary arteries. It was found that delayed contrast enhancement in the distal segment correlated with angiographic stent obstruction (Spearman's rank correlation, P=0.008), while all other indicators of stent occlusion did not correlate with angiographic diagnosis. However, direct comparison of patients with obstruction of less vs. more than 75% of luminal diameter did not yield any statistically significant differences of distal enhancement delay, and for the detection of >90% occlusion, the sensitivity was 72% at a specificity of 60%. Although delayed contrast enhancement distal to the stent upon EBCT did correlate with angiographical obstruction, the correlation did not suffice to appear clinically satisfactory.

Adult↗

Gauging effective spatial resolution in multirow helical cardiac computed tomography with a dynamic phantom.

PURPOSE: To devise a numerical indicator of image quality for multirow helical cardiac computed tomography (CT) and its relation to temporal resolution. MATERIALS AND METHODS: A pulsatile cardiac assist device was used to simulate cardiac wall motion by mechanically transmitting the device dynamics to a piece of tungsten wire. Wire motion induced by different device rates was captured with an 8-row subsecond helical CT scanner operating with various scanning parameters. Image artifacts were visually assessed and compared with the image point spread function (PSF) using the full width at half maximum (FWHM) area as a numerical estimate of spatial accuracy. RESULTS: At rest, the FWHM area was determined as 1.3 mm2. At a device rate of 60 bpm, the FWHM area ranged from 1.51 mm2 to 21.62 mm2, depending on the time of image reconstruction. Mean reproducibility of the FWHM area measurements was determined as 0.05, whereas visual estimates of motion artifact were highly variable between different readers (kappa = 0.19). Visually determined image quality correlated closely with the FWHM area metric (Spearman's rank correlation, P = 0.0001, rho = 0.841). At a device rate of 100 bpm, the minimum FWHM area was 2.00 mm2 using a single-sector algorithm, 1.41 mm2 using a 2-segment algorithm, and 1.37 mm2 using a 4-segment algorithm. CONCLUSIONS: Use of a pulsatile cardiac assist device could serve as an in vitro test bed for cardiac CT imaging methods. Area FWHM of the PSF correlates well with visually determined image quality of a dynamic phantom, but provides better reproducibility than visual analysis.

Algorithms↗

Dynamic high-resolution electron-beam CT scanning for the diagnosis of bronchiolitis obliterans syndrome after lung transplantation.

PURPOSES: To determine the diagnostic capabilities of dynamic high-resolution electron-beam (HREB) CT scanning for diagnosing bronchiolitis obliterans syndrome (BOS) in lung transplant recipients. MATERIALS AND METHODS: At the time of follow-up examinations after lung transplantation, 52 patients were examined by dynamic HREB CT scan. Visual signs of small airway disease were assessed and compared with lung function. For numerical analysis, the mean lung attenuation and its SD were determined and compared with the course of lung function tests. RESULTS: On visual analysis, significant parenchymal attenuation inhomogeneities were present in eight of nine patients with manifest BOS, and in two of four patients who developed BOS during follow-up. Thirteen of 20 patients with persistent normal lung function displayed homogeneous lung attenuation. On numerical analysis, mean lung attenuation was significantly lower in patients who developed BOS during follow-up than in patients with persistent normal lung function (both in expiration and inspiration, p < 0.0001). With an optimal threshold, the sensitivity was 100% (4 of 4 patients) and the specificity was 90% (19 of 20 patients). In patients with BOS at the time of the CT scan examination, parenchymal attenuation was less homogeneous than in patients with persistent normal lung function (p < 0.0001). With an optimal threshold, the sensitivity was 78% (7 of 9 patients) and the specificity was 85% (17 of 20 patients). CONCLUSIONS: Dynamic HREB CT of lung transplant recipients correlates well with lung function criteria of BOS at the time of the CT examination and with the subsequent progression to BOS.

Adolescent↗

Coronary artery calcium scoring: diagnostic accuracy of different software implementations.

PURPOSE: To compare the diagnostic power of different software implementations for the quantification of coronary artery calcium. MATERIALS AND METHODS: Electron beam computed tomography was performed in 109 heart transplant recipients at the same time as catheter coronary angiography and intracoronary ultrasound. Electron beam computed tomography images were analyzed by 3 software packages marketed for the quantification of coronary calcifications using the same software settings, and the resultant calcium scores correlated with the invasive reference methods by Bland-Altman plots and analysis of the receiver operating characteristics. RESULTS: Although all scoring systems displayed close correlations upon regression analysis (r2=0.94-0.99), their ability to detect disease as per the invasive reference method varied significantly in some instances. The area under the ROC curve varied between Az=0.78 and 0.85 for the detection of coronary artery stenosis upon coronary angiography (P=0.05-0.13), and between Az=0.75 and 0.83 for the detection of accelerated intimal proliferation (P=0.03-0.18). CONCLUSIONS: Different software implementations for the quantification of coronary artery calcium load may display diagnostically relevant differences in spite of close direct correlation.

Adolescent↗

Magnetic resonance imaging of inflammatory bowel disease: evaluation in a rabbit model.

PURPOSE: To correlate intestinal contrast enhancement and wall thickening with the degree of inflammation in an experimental model of inflammatory bowel disease. MATERIALS AND METHODS: Inflammatory bowel disease was elicited in 39 New Zealand White rabbits by rectal instillation of 2,4,6-trinitrobenzene sulphonic acid (TNBA). Magnetic resonance imaging (MRI) was used to determine bowel wall thickness and intestinal contrast enhancement after the administration of 0.1 mmol/kg of gadodiamide intravenously. MR measurements were compared with the complete histopathologic analysis. RESULTS: MR measurements of bowel wall thickness correlated well with histopathologic measurements in vitro (r = 0.85, P < 0.0001) and with histopathologic evidence of chronic inflammatory bowel disease (P < 0.02). Chronic inflammation was characterized by increased intestinal contrast enhancement (137 +/- 25%) when compared to normal bowel (86 +/- 7%, P = 0.04). CONCLUSION: Contrast-enhanced MRI accurately reflects inflammatory bowel disease in the rabbit model.

Animals↗

Bronchiolitis obliterans syndrome in lung transplant recipients: use of spirometrically gated CT.

PURPOSE: To assess the potential use of spirometrically gated lung computed tomographic (CT) findings in the diagnosis of bronchiolitis obliterans syndrome after lung transplantation. MATERIALS AND METHODS: Forty-nine lung transplant recipients were examined at least 8 months after surgery with spirometrically gated thin-section CT of the lung. In addition to visual signs of small-airway disease at CT, mean lung attenuation and the SD were numerically determined and compared with the results of lung function testing at the time of the CT examination and 1 year later by using factorial analysis of variance. RESULTS: Mean lung attenuation was significantly lower in patients who developed bronchiolitis obliterans syndrome within 1 year after the CT study (-837 HU +/- 3) than in patients with persistent normal lung function (-812 HU +/- 3, P <.001). With an optimal threshold, sensitivity was 69%, specificity was 71%, and accuracy was 84%. Visual analysis did not significantly contribute to the prognostic power of CT. CONCLUSION: Spirometrically gated CT measurements of lung attenuation can be used to predict the onset of bronchiolitis obliterans syndrome after lung transplantation.

Adult↗