PubMed Health⌕ Search

Biomedical subjects

Friedrich Graef

Publications and source records attributed to Friedrich Graef.

5 recordsLinked to original sources

Loading of bone surrounding implants through three-unit fixed partial denture fixation: a finite-element analysis based on in vitro and in vivo strain measurements.

Implant-borne fixed partial dentures (FPDs), whether cementable or screwable superstructures, ought to display a true passive fit. The objective of this in vivo-based finite-element analysis is, therefore, to quantify the degree of stress which occurs in the bone around the implants as a result of the fixation of cemented and screw-retained FPDs. On the basis of a simulated patient situation with two implants, six groups of implant-supported superstructures containing 10 samples each were fabricated. Strain gauges which were mounted on the pontics of the restorations were subsequently used to take in vivo measurements (Ethics Commission Approval No. 2315). Taking the values obtained as a basis, the von Mises equivalent stress was chosen to illustrate bone loading in three-dimensional finite-element models. Superstructure fixation caused residual interface stress as high as 30 MPa. Similar stress magnitudes can be observed for axial implant loading of 200 N. Assuming that the axial loading of a single implant with 200 N is within the bone's physiological range, it can be concluded that the degree of stress resulting from the fixation of superstructures alone does not constitute a risk.

Cementation↗

Static implant loading caused by as-cast metal and ceramic-veneered superstructures.

STATEMENT OF PROBLEM: The passive fit of superstructures for implant-supported restorations is affected by each step of the fabrication process. In this context the question arises whether ceramic veneering would increase static implant loading. PURPOSE: The purpose of this study was to quantify the strain development of various fixed partial dentures (FPDs) both in the as-cast condition and after ceramic veneering. MATERIAL AND METHODS: Four different types (n = 10) of 5-unit FPDs (cementable, screw retained/plastic cylinder, screw retained/gold cylinder, screw retained/cemented) representing commonly used types of FPDs were investigated before and after ceramic veneering. Three implants were placed in a model simulating a patient situation, and strain gauges were mounted mesially and distally adjacent to the implants. The strain development was recorded during cement setting (provisional cement) and screw fixation. The data were analyzed statistically using multivariate 2-sample tests (alpha=.1). RESULTS: All FPDs revealed measurable amounts of strain. Neither the type of retention nor the mode of fabrication for conventional screw-retained FPDs had a significant influence on strain development. Ceramic veneering caused an increase in strain development for the conventional fixed partial dentures tested. The lowest strains were found in FPDs cemented to gold cylinders on the model for the metal frames and the ceramic-veneered FPDs. CONCLUSION: Conventional procedures were unable to produce superstructures with absolute passive fit. Ceramic veneering appeared to increase strain development and, thus, inaccuracy of the fit. The technique of cementing superstructures to prefabricated components directly on the implants may compensate for dimensional errors caused by impression making and superstructure fabrication.

Cementation↗

Strain situation after fixation of three-unit ceramic veneered implant superstructures.

The passive fit of superstructures used in implant prosthodontics is affected by several variables. The objective of this study was to quantify the strain development in various fixed partial dentures (FPDs), both in the condition as cast and after ceramic veneering. Five different types of three-unit FPDs (cementable/repositioning technique impression; cementable/pick-up technique impression; screw-retained/plastic cylinder; screw-retained/gold cylinder; screw-retained/bonded) with 10 samples each, representing commonly used FPD-types, were investigated before and after ceramic veneering. Two ITI implants were anchored in a measurement model simulating a real-life patient situation and strain gauges were mounted close to the implants. The strain development was recorded during cement setting and screw fixation. For statistical analysis, multivariate two-sample tests were performed with the level of significance set at P = 0.1. All FPDs revealed measurable amounts of strain. Neither the impression technique nor the fabrication modes for conventional screw-retained FPDs had a significant influence on strain development. Ceramic veneering caused an increase in strain development for the conventional bridge types. Furthermore, cementing appears to be able to compensate fabrication inaccuracies better than screw retention. The lowest strains were found in FPDs bonded to gold cylinders on the measurement model for metal frames and ceramic-veneered FPDs. Conventional procedures are unable to produce superstructures with an absolute passive fit. The technique of bonding superstructures to prefabricated components in the oral cavity seems to compensate for various shortcomings in superstructure fabrication.

Cementation↗

Cement fixation and screw retention: parameters of passive fit. An in vitro study of three-unit implant-supported fixed partial dentures.

It is generally assumed that passively fitting superstructures are a prerequisite for long-lasting implant success. In the study presented, the strain development of three-unit implant fixed partial dentures (FPDs) was evaluated at the bone surrounding the implant and on the superstructure using a strain gauge technique. Six groups of three-unit FPDs representing the commonly used techniques of bridge fabrication were investigated with 10 samples each, in order to quantify the influence of impression technique, mode of fabrication and retention mechanism on superstructure fit. Two ITI implants (Straumann, Waldenburg, Switzerland) were anchored in a measurement model according to a real-life patient situation and strain gauges were fixed mesially and distally adjacent to the implants and on the bridge pontics. The developing strains were recorded during cement setting and screw fixation. For statistical analysis, multivariate two sample tests were performed setting the level of significance at P=0.1. None of the investigated bridges revealed a truly passive fit without strains occurring. About 50% of the measured strains were found to be due to impression taking and model fabrication, whereas the remaining 50% were related to laboratory inaccuracies. The two impression techniques used did not reveal any significant differences in terms of precision. Both modes of fixation--i.e. cement and screw retention--provoked equally high stress levels. In the fabrication of screw-retained FPDs, similar results were obtained from the use of burn-out plastic copings and the technique of casting wax moulds to premachined components. Bonding bridge frames onto gold cylinders directly on the implants significantly reduces strain development.

Aged↗

Mandibular two-implant telescopic overdentures.

To stabilize mandibular overdentures in edentulous patients, various connector types which can be attached to between two and four implants placed in the anterior mandible are possible. Treatment using non-rigid telescopic connectors on two interforaminal implants for overdenture stabilization began in 1989. The objective of this study is to investigate soft- and hard-tissue conditions as well as prosthesis function after a period of 10 years. This also involved an evaluation of correlations between radiographic and clinical parameters. Twenty-three subjects with 46 interforaminal implants (ITI solid screw implants, 12 mm in length, 4.1 mm in diameter; 10.4 years in situ, range, 8-12.8 years) were investigated. Modified plaque index (mPI), sulcus fluid flow rate (SFFR), modified sulcus bleeding index (mBI), probing depth (PD), distance from implant crown margin to the coronal border of the peri-implant mucosa (DIM), attachment level (AL), width of keratinized mucosa (KM), Periotest values (PTVs) and prosthesis function were evaluated. In the radiographic evaluation, the distance between implant shoulder and first crestal bone-implant contact (DIB) in mm and the horizontal bone loss (HBL) in mm were measured. The relatively high mPI scores (mean, 0.82; score, 0 in 44.4%; SD, 0.83) did not result in increased SFFR scores (mean, 12; min, 3, max, 38; SD, 7.43) or higher mBI scores (mean, 0.35; score, 0 in 70.8%; SD, 0.59), which was commensurate with healthy peri-implant mucosa. A mean PD value of 2.15 mm (min, 1 mm; max, 5 mm; SD, 0.96) and a mean DIM value of 0.28 mm (min, 0 mm; max, 2 mm; SD, 0.52) were measured. The implants were stable, showing a mean Periotest value of -1.91 (max, 02, min, -6; SD, 1.76). A mean DIB of 3.19+/-0.95 mm (range, 1.3-5.16 mm) and a mean HBL of 1.6+/-1.52 mm (range, 0.28-8.33 mm) were calculated. A correlation was found between DIB and the parameters SFFR (P=0.060), DIM (P=0.042), AL (P=0.050) and especially PTV (P<0.01), leading to the assumption that these clinical parameters may be useful indicators of peri-implant bone loss. The results of the 10-year follow-up examination show that non-rigid telescopic connectors with two interforaminal implants for overdenture stabilization appear to be an efficient and effective long-term treatment modality in severely resorbed edentulous mandibles. Particularly in geriatric patient treatment this concept may provide advantages in terms of handling, cleaning and long-term satisfaction.

Aged↗