A biodegradable composite scaffold for cell transplantation.

Cell transplantation is rapidly becoming a therapeutic option to treat disease and injury. However, standard techniques for cell seeding on non-woven polymer meshes or within gels may not be suitable for immediate implantation or surgical manipulations of freshly isolated cells. Therefore, a biodegradable composite system was developed as a way to rapidly entrap cells within a support of predefined shape to potentially facilitate cell delivery into a target site (e.g. meniscal tears in the avascular zone). The composite construct consisted of freshly isolated cells, in this case pig chondrocytes, entrapped in a fibrin gel phase and dispersed throughout the void volume of a polyglycolic acid (PGA) non-woven mesh. Composites were cultured for up to 4 weeks. In vitro degradation of fibrin gel was evaluated via gel-entrapped urokinase. At 28 days in culture, glycosaminoglycan (GAG) content per cell in the composite scaffolds was 2.6 times that of the PGA-only cell construct group and 88% that of native pig cartilage. Total collagen content per cell in the composite scaffolds was not significantly different from the PGA-only cell construct group (P > 0.02) and represented 40% of the value determined for native cartilage. Varying the concentration of entrapped urokinase could effect controlled degradation of fibrin gel.

Absorbable Implants↗

Cell-killing potential of a water-soluble radical initiator.

The diazo compound, 2,2'-azobis [2-(2-imidazolin-2-yl) propane] dihydrochloride (AIPC), is a water-soluble radical initiator that can be activated at mild temperatures (37 degrees -40 degrees C). Potential biomedical applications of this compound include the fabrication of hydrogels by radical polymerization (e.g., cell encapsulation or drug delivery) and the thermal sensitization of cancerous cells to induce localized cell death. In this study we evaluated whether this compound could induce cell death at 37 degrees C in vitro and in vivo using a tumor animal model. Cytotoxicity was quantitated with a sulfo-rhodamine B colorimetric assay by monitoring growth inhibition of human glioma cells in vitro. AIPC was entrapped in fibrin gel and exposed to cells in culture as a potential way to localize the compound in a controlled release environment. The mechanism of action for cell death was evaluated by quantitating caspase-3 activity in cells. In vivo studies included human glioma tumors that were grown subcutaneously in rats to study the effect of intra-tumor injections of AIPC. AIPC was also injected subcutaneously into normal tissue. Concentrations of 0.2% and 0.02% (w/v in RPMI medium) showed 93% and 84% inhibition of cell growth in vitro, respectively. Cell-growth inhibition using gel-entrapped AIPC was comparable to that obtained with AIPC in solution after 48 hr (86% inhibition at 0.2% w/v). Exposure to AIPC resulted in a significant increase of caspase activity (up to 163 units after 20 min), suggesting induced apoptosis as a possible mechanism of action of the AIPC. Histological pictures showed that, relative to normal tissue, cancerous tissue was more sensitive to the effects of AIPC.

Animals↗

A novel immunoadsorption device for removing beta2-microglobulin from whole blood.

BACKGROUND: High plasma levels of beta2-microglobulin (beta2m) have been implicated in the formation of the severely destructive and potentially fatal amyloid deposits that are characteristic of dialysis-related amyloidosis (DRA). Conventional renal replacement technologies remove insufficient quantities of beta2m to normalize plasma levels. This limitation arises because of nonspecific adsorptive qualities and reliance on size exclusion, which can also remove other middle molecular weight proteins. These nonspecific approaches also make it difficult to evaluate the role and contribution of middle molecular weight molecules to the pathology of DRA and other morbidities of end-stage renal disease. A high-affinity and biologically specific approach could target a protein, prevent a significant loss of other important molecules, and improve the apparent adsorption rate within an extracorporeal device. METHODS: Agarose-immobilized murine anti-human beta2m monoclonal antibodies were used in a Vortex Flow Plasmapheretic Reactor (VFPR) to remove donor baseline and controlled amounts of recombinant beta2m from human blood in vitro. The extracorporeal circuit was hemoperfused at 200 mL/min for two hours. RESULTS: The immunoadsorptive media had a binding site density of 30 microg beta2m per mL of settled gel. The VFPR cleared baseline quantities of donor beta2m below detectable limits of the assay. The experiments with higher initial beta2m concentrations reached an equilibrium concentration within 20 minutes, corresponding to a 92% clearance. No deleterious hemocompatibility issues were observed (complete blood count, total protein, and plasma free hemoglobin). CONCLUSIONS: The adsorptive kinetics of the VFPR are optimal for the conditions used and support the use of immunoadsorption for the removal of beta2m.

Blood Component Removal↗

Regional heparinization via simultaneous separation and reaction in a novel Taylor-Couette flow device.

The development of a safe and efficient bioreactor design has remained a challenge for the clinical application of immobilized enzymes. Specifically, the use of immobilized heparinase I has been the target of many studies to make heparin anticoagulation therapy safer for the critically ill patient with kidney failure or heart disease. We have investigated the use of Taylor-Couette flow for a novel type of bioreactor. In a previous study, we showed that the fluidization of agarose immobilized heparinase within Taylor vortices in whole blood can lead to extensive blood damage in the form of cell depletion and hemolysis. Based on these findings, we designed and developed a reactor, referred to as vortex-flow plasmapheretic reactor (VFPR), that incorporated plasmapheresis and fluidization of the agarose in the reactive compartment, separate from the whole-blood path. In the present study, immobilized heparinase I was tested as a means of achieving regional heparinization of a closed circuit. This is a method in which heparin is infused into the extracorporeal circuit predialyzer and neutralized postdialyzer. Saline studies were performed with an immobilized heparinase I-packed bed and with the VFPR. An in vitro feasibility study was performed with the VFPR using human blood. The VFPR achieved heparin conversions of 44 +/- 0.5% and 34 +/- 2% in saline and blood, respectively. In addition, the VFPR caused no blood damage. We report a novel method to achieve fluidization which depended on secondary, circumferencial flow, and was independent of the primary flow through the device.

Biocompatible Materials↗

Investigation of a whole blood fluidized bed Taylor-Couette flow device for enzymatic heparin neutralization.

The use of clinical bioreactors will increase as more therapeutic proteins are being cloned, expressed, and produced at a reduced cost. The proposed use of an immobilized heparinase I reactor to make heparin anticoagulation a safer therapy is an example of how the specificity and high activity of an enzyme could be incorporated into a system to ultimately benefit a patient. However, the development of a safe and efficient bioreactor is important for the use of immobilized heparinase I and other therapeutic proteins designed for use in medical extracorporeal procedures. This study examined the possibility of using Taylor-Couette flow and "flow-induced" recirculation of the agarose beads as a way to fluidize agarose-bound heparinase in whole blood. Heparinase I was immobilized onto agarose beads via cyanogen bromide activation. A reactor based on Taylor-Couette flow was designed and modified with a tangential recirculation line. The reactor was tested for efficacy and safety in vitro in human blood. Visualization studies in water and 42% glycerol were used to determine the minimum rotation rate for efficient fluidization. The strategic placement of the recirculation line allowed recirculation of the agarose without the use of an external pump. The device removed 90% of the heparin activity within 2 min from 450 cc of human blood at a blood flow rate of 100 mL/min. Furthermore, the device maintained inlet and outlet clotting times of 269 +/- 10 and 235 +/- 6 s, respectively, demonstrating the potential for regional heparinization. Blood damage was a function of gel volume fraction and rotation rate of the inner cylinder. Hemolysis of the red cells is an important issue when Taylor vortices are combined with macroscopic solid particles such as agarose beads. A modified Taylor-Couette flow device was developed to treat whole blood and operational criteria were established to minimize hemolysis.

Bioreactors↗

Ex vivo evaluation of a Taylor-Couette flow, immobilized heparinase I device for clinical application.

Efficient and safe heparin anticoagulation has remained a problem for continuous renal replacement therapies and intermittent hemodialysis for patients with acute renal failure. To make heparin therapy safer for the patient with acute renal failure at high risk of bleeding, we have proposed regional heparinization of the circuit via an immobilized heparinase I filter. This study tested a device based on Taylor-Couette flow and simultaneous separation/reaction for efficacy and safety of heparin removal in a sheep model. Heparinase I was immobilized onto agarose beads via cyanogen bromide activation. The device, referred to as a vortex flow plasmapheretic reactor, consisted of two concentric cylinders, a priming volume of 45 ml, a microporous membrane for plasma separation, and an outer compartment where the immobilized heparinase I was fluidized separately from the blood cells. Manual white cell and platelet counts, hematocrit, total protein, and fibrinogen assays were performed. Heparin levels were indirectly measured via whole-blood recalcification times (WBRTs). The vortex flow plasmapheretic reactor maintained significantly higher heparin levels in the extracorporeal circuit than in the sheep (device inlet WBRTs were 1. 5 times the device outlet WBRTs) with no hemolysis. The reactor treatment did not effect any physiologically significant changes in complete blood cell counts, platelets, and protein levels for up to 2 hr of operation. Furthermore, gross necropsy and histopathology did not show any significant abnormalities in the kidney, liver, heart, brain, and spleen.

Acute Kidney Injury↗

Modalities for the removal of beta 2-microglobulin from blood.

The long-term accumulation of beta(2)-microglobulin (beta(2)M) in patients with kidney failure results in a debilitating condition referred to as dialysis-related amyloidosis (DRA). There have been few methods specifically designed to remove the large quantities of beta(2)M that are produced by the body. This article briefly reviews current modalities and concepts for the removal of beta(2)M from blood. The various approaches are classified according to the mechanism of beta(2)M clearance. The potential application of immunoadsorption, a biologically specific approach to remove macromolecules, in the treatment and understanding of DRA is discussed.

Amyloidosis↗