PubMed Health⌕ Search

Biomedical subjects

G A Gescheider

Publications and source records attributed to G A Gescheider.

At least 37 records · Page 2Linked to original sources

Vibrotactile forward masking as a function of age.

Thresholds for the detection of a 50-ms test stimulus delivered to the thenar eminence were measured as a function of the time interval between the offset of a 500-ms masking stimulus and the onset of the test stimulus (delta t). The frequency of the masker and the test stimulus was the same during a particular testing session and was either 25 or 250 Hz. At all values of delta t, older subjects exhibited significantly more masking than did young subjects. The effects of age were greater for stimuli that primarily affect the Pacinian system (250 Hz) than those that primarily affect non-Pacinian systems (25 Hz). Psychophysical measurements of the apparent duration of tactile sensations suggest that both sensory persistence and adaptation are affected by aging. Since adaptation seemed to be the more dominant factor for stimuli with durations as long as 500 ms, it was concluded that the effects of aging on forward masking seen in our study were due mainly to increased amounts of adaptation produced by the masker.

Adolescent↗

Effects of noise on detection of amplitude increments of sinusoidal vibration of the skin.

Vibrotactile thresholds for detecting a 300-Hz signal in the presence of both a 300-Hz sinusoidal pedestal and a background noise were measured as a function of the amplitudes of the pedestal and noise. Threshold increased monotonically as a function of the amplitude of the noise, but was a nonmonotonic function of the amplitude of the sinusoidal pedestal. Negative masking, in which the pedestal facilitated detection of the test stimulus, was observed in the absence of background noise and in the presence of subthreshold background noise when the pedestal was near or below threshold. Negative masking disappeared when the experiment was conducted in the presence of moderately intense to intense background noise. The results are consistent with a peripheral high-energy threshold for taction.

Adult↗

Stimulus context and absolute magnitude estimation: a study of individual differences.

The effect of stimulus context on absolute-magnitude-estimation (AME) judgments was examined by determining whether the loudness judgment of a tone is influenced by the intensities of other tones presented within the session. A group of 18 subjects was tested in separate sessions in which they judged stimuli within either a low (10-60 dB SL) or a high (40-90 dB SL) range of intensities. Examination of the results of individual subjects revealed that judgments of stimuli common to the two ranges were, in most subjects, unaffected or only slightly affected by the position of the range. The judgments of 2 subjects who failed to follow the instructions, however, showed very large context effects due to changing the stimulus range. The results of a second experiment, in which 22 subjects judged the loudness of tones within either a narrow (35-65 dB SL) or a wide (20-80 dB SL) range, revealed that, in all but 1 subject, the width of the range had no systematic effect on the loudness judgments of stimuli common to both ranges. This was also true 1 month later when 16 of the subjects returned to the laboratory to judge the loudness of tones within an even wider range of 10-90 dB SL. It was concluded that AME judgments are relatively insensitive to the potential biasing influences of stimulus context.

Adult↗

Vibrotactile temporal gap detection as a function of age.

The ability of subjects to detect temporal gaps between bursts of sinusoids or bursts of bandlimited noise was measured to evaluate the phenomenon of tactile "sensory persistence" in older persons. Vibratory stimuli were delivered to the right thenar eminence of 27 subjects ranging in age from 8-75 years. The subjects' task was to detect the presence of a silent interval or "gap" between flanking 350-ms vibrotactile stimuli. The gap-detection threshold, expressed as the amplitude of vibration relative to the absolute detection threshold, decreased as the gap duration increased and was higher for gaps in noise than for gaps in sinusoids. The threshold for detecting short gaps increased with age for noise stimuli, but not for sinusoidal stimuli. Furthermore, the gap-detection threshold recovered more rapidly in older subjects for noise stimuli, but less rapidly in older subjects for sinusoidal stimuli. Because of these differences, it appears that the effects of age on gap detection cannot be due to a simple increase in sensory persistence, but may be due to multiple processes.

Adolescent↗

Vibrotactile intensity discrimination measured by three methods.

The difference threshold for the detection of changes in vibration amplitude was measured as a function of the intensity and frequency of stimuli delivered through a 2.9-cm2 contactor to the thenar eminence. Stimuli were either 25- or 250-Hz sinusoids, narrow-band noise centered at 250 Hz, or wideband noise. Thresholds were measured by two-interval, forced-choice tracking under three methods of stimulus presentation. In the gated-pedestal method, subjects had to judge which of two 700-ms bursts of vibration separated by 100 ms was more intense. In the continuous-pedestal method, subjects had to detect a 700-ms increment in the amplitude of an ongoing pedestal of vibration. In the two-burst-continuous-pedestal method with 1500-ms pedestals, the subject had to detect which of two successively presented pedestals contained a 500-ms amplitude increment. Thresholds were consistently lower for detecting increments in the amplitude of a continuous pedestal of vibration than for detecting amplitude differences between briefly presented successive pedestals or amplitude increments in successive pedestals. A "near miss" to Weber's law was found both for sinusoidal and for noise stimuli. The difference threshold was not affected by stimulus frequency condition.

Adult↗

The measurement of loudness in individual children and adults by absolute magnitude estimation and cross-modality matching.

Twelve adults and 11 children (age range 4-7 years) performed absolute magnitude estimation of the apparent lengths of lines and the loudnesses of 1000-Hz tones as well as cross-modality matching between loudness and apparent line length. Consistent with the notion that children and adults have similar impressions of loudness, there were no major differences between the absolute magnitude estimation (AME) and cross-modality matching (CMM) data of the adults and children. A direct comparison between the exponents for loudness by AME and CMM was made when a correction factor was employed to eliminate the effects of idiosyncratic use of numbers from the AME exponents. The results support the hypothesis that, with proper instructions, both children and adults can judge stimuli on an absolute scale. Specifically, for 9 out of 12 adults and 9 out of 11 children, lines and tones assigned the same number in absolute magnitude estimation were judged to be subjectively equal in cross-modality matching.

Adult↗

Vibrotactile masking: effects of stimulus onset asynchrony and stimulus frequency.

Vibrotactile thresholds for the detection of a 50-ms vibratory stimulus on the thenar eminence of the hand were measured in the presence of and in the absence of a 700-ms suprathreshold vibratory masking stimulus. When thresholds were measured in the presence of the masking stimulus, stimulus onset asynchrony (SOA) was varied so that backward, simultaneous, and forward masking could be measured. The amount of masking, expressed as threshold shift, was greatest when the test stimulus was presented near the onset or offset of the masking stimulus. For both backward and forward masking, the amount of masking decreased as a function of increasing stimulus onset asynchrony. Comparisons were made of the amounts of masking measured when the test and masking stimuli were both sinusoids, and when the test stimulus was a sinusoid and the masking stimulus was noise. In all conditions, the masked threshold decreased approximately 4.0 dB when SOA was increased from 100 to 650 ms with reference to the onset of the 700-ms masking stimulus. More simultaneous masking was observed when sinusoidal test stimuli were detected in the presence of noise than when they were detected in the presence of sinusoidal maskers of the same frequency. The functions were essentially identical for detection of a low-frequency (20 Hz) test stimulus mediated by a non-Pacinian channel and detection of a high-frequency (250 Hz) test stimulus mediated by the Pacinian channel.

Adult↗

Four channels mediate the mechanical aspects of touch.

Although previous physiological and anatomical experiments have identified four afferent fiber types (PC, RA, SA II, and SA I) in glabrous (nonhairy) skin of the human somatosensory periphery, only three have been shown to mediate tactile (mechanoreceptive) sensation. Psychophysical evidence that four channels (P, NP I, NP II, and NP III) do, indeed, participate in the perceptual process is presented. In a series of experiments involving selective masking of the various channels, modification of the skin-surface temperature, and testing cutaneous sensitivity down to very low-vibratory frequencies, the fourth psychophysical channel (NP III) is defined. Based on these experiments and previous work from our laboratory, it is concluded that the four channels work in conjunction at threshold to create an operating range for the perception of vibration that extends from at least 0.4 to greater than 500 Hz. Each of the four channels appears to mediate specific portions of the overall threshold-frequency characteristic. Selection of appropriate neural-response criteria from previously published physiological data and correlation of their derived frequency characteristics with the four psychophysical channels indicates that each channel has its own physiological substrate: P channel and PC fibers, NP I channel and RA fibers, NP II channel and SA II fibers, and NP III channel and SA I fibers. These channels partially overlap in their absolute sensitivities, making it likely that suprathreshold stimuli may activate two or more of the channels at the same time. Thus the perceptual qualities of touch may be determined by the combined inputs from four channels.

Adult↗

Vibrotactile forward masking: psychophysical evidence for a triplex theory of cutaneous mechanoreception.

Threshold shifts for the detection of vibrotactile test stimuli were determined as a function of the intensity of a masker. A 50-ms sinusoidal test stimulus was applied to the thenar eminence of the hand 25 ms after the termination of a 700-ms sinusoidal masker applied to the same site. The frequency of the test stimulus and the frequency of the masker were varied. To eliminate the influence of the Pacinian receptor system, stimuli were delivered through a 0.01-cm2 contactor. The results support the hypothesis that the detection of vibration delivered through a small contactor is determined by two separate populations of non-Pacinian receptors. The study constitutes a psychophysical demonstration of the existence of three receptor systems responsible for the detection of vibration.

Adult↗

Vibrotactile forward masking: evidence for channel independence.

Threshold shifts for the detection of vibrotactile test stimuli were determined as a function of the intensity of a masker. A 50-ms sinusoidal test stimulus was applied to the thenar eminence of the hand 25 ms after the termination of a 700-ms sinusoidal masker applied to the same site. The intensity of the masker was varied over a range of 0-44 dB SL. The frequency of the masker was either 15 or 250 Hz and the frequency of the test stimulus was either 15, 25, 100, or 250 Hz. The results support the hypothesis that the detection of vibrotactile stimuli is mediated by at least two receptor systems which do not mask each other.

Adolescent↗