PubMed Health⌕ Search

Biomedical subjects

G A Machicado

Publications and source records attributed to G A Machicado.

21 records · Page 2Linked to original sources

Comparison of argon laser photocoagulation and bipolar electrocoagulation for endoscopic hemostasis in the canine colon.

Severe bleeding from the lower gastrointestinal tract commonly occurs from mucosal lesions such as angiodysplasia and less often from acute ulcerations. Endoscopic coagulation of such lesions is now feasible. Our purpose was to compare the efficacy and histologic injury of bipolar electrocoagulation and argon laser photocoagulation applied at laparotomy in the canine colon. After right colotomy and heparinization in adult mongrel dogs, bleeding standard ulcers were randomly assigned to treatment or control. The colonic ulcers randomized to each group were not significantly different in size or bleeding rate. Efficacy of treatment was evaluated acutely. Adjacent normal mucosa was treated with the same modality as the ulcer to simulate treatment of a mucosal lesion. The same total exposure time (argon laser photocoagulation) or number of pulses (bipolar electrocoagulation) was used for these paired treatments. Gross and histologic injury were determined after 7 days. Both argon laser photocoagulation and bipolar electrocoagulation were uniformly effective in controlling bleeding from standard colonic ulcers and the incidence of full thickness injury was similar, 33%-48%. The histologic damage seen with normal mucosa treatment was consistently less than with standard ulcers for all treatment groups. The difference is easily explained by the reduction in colonic wall thickness of about 50% with creation of standard ulcers. In our opinion, argon laser photocoagulation and bipolar electrocoagulation are safe enough to be used in clinical trials for control of colonic bleeding from mucosal lesions but not acute colonic ulcers.

Animals↗

Prospective randomized comparative study of bipolar versus direct current electrocoagulation for treatment of bleeding internal hemorrhoids.

Internal hemorrhoids are the most common cause of lower gastrointestinal bleeding. Although new anoscopic therapies are available, few comparative randomized studies have evaluated them in regard to long-term efficacy, recurrence rates, and safety. Our purpose was to compare the treatment of internal hemorrhoids with direct current (Ultroid, Cabot Medical, Langhorn, Pa.) and bipolar (BICAP, Circon ACMI, Stamford, Conn.) hemorrhoid probes. One hundred patients with symptomatic internal hemorrhoids were randomized: 50 to direct current electrocoagulation and 50 to bipolar electrocoagulation. Follow-up and treatment were at 3- to 4-weekly intervals; two to three hemorrhoid segments were treated at each session until relief of symptoms (bleeding, prolapse, and discharge) and a reduction in hemorrhoid size to grade 1 or 0 were noted. The hemorrhoids of 98% of all patients studied were grade 2 or 3; 2% of patients had grade 1 hemorrhoids and none had grade 4 hemorrhoids. At 1 year after treatment, most patients had no (69%) or only mild (23%) recurrence, and a few had severe, symptomatic (8%) hemorrhoid recurrence. A greater recurrence rate was noted after direct current treatment (34%) than bipolar treatment (29%). In contrast, rebleeding at 1 year occurred less frequently after direct current treatment (5%) than after bipolar treatment (20%). Our conclusions were as follows: (1) Both direct current and bipolar probes were effective for control of chronic bleeding from grade 1 to 3 internal hemorrhoids. (2) Bipolar probe was significantly faster than direct current probe. (3) Direct current treatment produced fewer complications than bipolar treatment (12% versus 14%). (4) Recurrence rates were low after 1 year with either device (8%).(ABSTRACT TRUNCATED AT 250 WORDS)

Electrocoagulation↗