Dynamic in vitro and in vivo performance of a permanent total artificial heart.

In vivo characterization studies were performed to compare the dynamic in vivo performance of the Penn State/3M Health Care electric total artificial heart to existing in vitro data. Fully implanted systems were utilized including the artificial heart, controller, backup batteries, compliance chamber, and transcutaneous energy transmission. Catheters were implanted to measure central venous pressure (CVP), left atrial pressure (LAP), right atrial pressure (RAP), pulmonary artery pressure (PAP), and aortic pressure (AoP). Cardiac output (CO) was determined from the implanted controller, and systemic vascular resistance (SVR) was calculated. Steady state data were collected for each animal along with data regarding the transient responses to changes in preload and afterload. Preload was manipulated through volume changes. Afterload changes were accomplished through vasoactive agents. Increased preload caused little change in cardiac output because the pump output was nearly maximum at baseline. LAP, AoP, and SVR increased with increasing RAP. Decreased preload caused a reduction in CO, LAP, and SVR. Afterload increase resulted in a slight decrease in flow and an increase in system power and SVR. Afterload reduction was accompanied by a decrease in preload and a concomitant reduction in flow. Overall, the system response was similar to the response observed in vitro.

Animals

Pulmonary circulatory support. A quantitative comparison of four methods.

Profound right ventricular failure was produced in 16 goats by inducing ventricular fibrillation after the systemic circulation had been supported with a left atrial-aortic bypass pump. In each animal, four methods of providing pulmonary blood flow were compared quantitatively: passive flow through the pulmonary artery due to a right atrial to left atrial pressure gradient; pulmonary artery pulsation via a 40 ml intra-aortic type balloon within a 20 mm Dacron graft anastomosed to the main pulmonary artery; pulmonary artery pulsation via a 65 ml single-port, valveless, sac type pulsatile assist device; and right atrial-pulmonary arterial bypass via a valved pneumatic pulsatile pump. Average cardiac index of the 16 animals for each method was 31.1 +/- 12.9, 44.4 +/- 13.6, 64.3 +/- 16.9, and 102.0 +/- 20.7 ml/min/kg, respectively. Passive pulmonary artery flow alone provided inadequate pulmonary circulatory support. Addition of pulmonary artery pulsation via the intra-aortic balloon within a conduit increased cardiac index 13.3 ml/min/kg (43%) above passive pulmonary artery flow (p less than 0.0005); however, the cardiac index remained inadequate. Increasing pulmonary artery pulsation volume with a 65 ml sac device provided a 32.2 ml/min/kg (106%) increase in cardiac index above passive flow (p less than 0.0005) to a level that was marginally adequate. The valved right atrial-pulmonary arterial bypass pump increased cardiac index 70.9 ml/min/kg (228%) above passive pulmonary artery flow (p less than 0.0005) to a satisfactory level and is the recommended method of pulmonary circulatory support in profound right ventricular failure.

Animals

Vascular anastomoses in growing vessels: the use of absorbable sutures.

Primary end-to-end infrarenal aortic anastomoses were performed in 36 piglets using two synthetic absorbable suture materials: polydioxanone and coated polyglactin. Animals were killed at 1, 4, and 11 weeks and 6 months following operation. Each aorta was removed, burst-tested to 300 mm Hg, radiographed, and examined histologically. All anastomoses were patent, and no burst-test failures occurred. Stenosis occurred in 14 of 17 animals at 1 and 4 weeks, respectively. One of 5 animals exhibited stenosis at 11 weeks, and none of the 14 animals had stenosis 6 months postoperatively. Histological examination revealed fibrosis replacing areas of disrupted elastica at 6 months in both suture groups. This study suggests that absorbable suture material, in particular polydioxanone, because of its excellent handling characteristics and prolonged tensile strength retention, will be useful for the repair of vascular and cardiac anomalies where growth of the suture line is required.

Absorption

Primary vascular anastomosis in growing pigs: comparison of polypropylene and polyglycolic acid sutures.

Stenosis remains a significant problem in vascular anastomoses performed in the growing patient. This study compares the growth of vascular anastomoses performed with either polypropylene or polyglycolic acid sutures. End-to-end infrarenal aortic anastomoses were performed in 18 piglets. Twelve were performed with polypropylene; in six all sutures were placed in a continuous fashion (Group 1A), and in the other six the posterior sutures were continuous and the anterior were interrupted (Group B). Six anastomoses were performed with polyglycolic acid sutures placed in a continuous fashion (Group 2). The animals were killed 6 months following operation. The abdominal aorta was removed, measured, burst tested, and subjected to histologic studies. All anastomoses were patent. There were no burst failures at 300 mm Hg mean pressure. All polypropylene sutures in Group 1A and the continuous portion in Group 1B had straightened without breaking. Straightening without polypropylene suture breakage resulted in stricture in three Group 1A anastomoses and one Group 1B anastomosis; there was intraluminal polypropylene suture material in two Group 1A and five Group 1B anastomoses. Bowstring formation of the straightened, continuous portion of the polypropylene suture in two Group 1A anastomoses and one Group 1B anastomosis resulted in adherent thrombus. Group 2 anastomoses were without stricture and were grossly indistinguishable from adjacent normal vessel. Histologic examination showed varying degrees of chronic inflammation in the polypropylene anastomoses but negligible inflammation in the polyglycolic acid anastomoses. These results suggest that continuous suture techniques with polypropylene in growing vessels may result in stenosis and/or thrombosis. Moreover, synthetic absorbable polyglycolic acid sutures will be of use in vascular anastomoses in growing patients and in cases in which exacting technique with minimal postsurgical inflammation may be crucial to patency.

Animals

Approaches to the artificial heart. Invited speaker.

Over the last two decades, the implantable artificial heart has evolved from an idea to a device capable of completely supporting the circulation for periods now exceeding 5 months. Although initial animal studies were limited by thromboembolism and device breakage, the usual causes of death in experimental animals are now infection, atrioventricular valve obstruction, elastomer bladder calcification, or inadequate cardiac output because of the relatively rapid growth of the young calves. As a result of the bulky nature of the energy converter and the substantial risk of infection with large diameter percutaneous tubes, clinical use of their air-powered artificial hearts will be limited to patients who are awaiting or being prepared for heart transplantation. Artificial hearts with implanted energy converters are being developed for permanent heart replacement. These devices require well-designed, durable mechanical components and sophisticated control systems. Although initial designs centered around thermal engines powered by a completely implantable nuclear energy source, the excessive cost and potential dangers have shifted the focus away from the nuclear system. Several electrically driven artificial hearts, based on samarium-cobalt magnet brushless direct-current motors, are now undergoing bench testing and will be ready for long-term animal studies within 2 years. This research will culminate with the availability of an "off-the-shelf" electrically powered artificial heart for use in patients with a wide range of nonrepairable forms of end-stage heart disease.

Animals

Mechanical circulatory assistance for postoperative cardiogenic shock: a three year experience.

Retrospective analysis of 14 patients undergoing circulatory support for postcardiotomy cardiogenic shock during the past 3 yrs has demonstrated the ability of the profoundly depressed myocardium to recover. Four patients were totally weaned from circulatory support and 2 are long-term survivors. Our results suggest that improved survival is dependent on the absence of certain peri-operative complications. To improve future clinical results we suggest that prompt application of assist pumping is necessary to eliminate prolonged cardiopulmonary bypass times and subsequent massive bleeding; those circulatory support systems requiring systemic anticoagulation are of no value in the treatment of postcardiotomy cardiogenic shock; the use of atrial cannulation may be advantageous in certain patients to eliminate critical inflow obstruction, further prolongation of cardiopulmonary bypass, and additional myocardial damage; and that the high incidence of right ventricular failure that is refractory to medical therapy makes the ability to support both ventricles mandatory.

Adult

Total artificial heart implantation in calves with pump on an angled port design.

The APP was employed in our 21st TAH calf and has now been implanted in a total of 11 animals. The APP has a dynamic stroke volume of 105 ml, an ejection fraction of 75%, and a peak flow of 14 L/min. The TAH features 2 APPs which have polysulfone cases and contain smooth, seam-free polyurethane sacs. Concavoconvex Bjork-Shiley valves are used. The pumps are pneumatically driven but may be easily converted to pusher-plate drive. A pneumatic drive console and an automatic control unit complete the system. The automatic control unit permits independent control of the right and left hearts as a function of left atrial and aortic pressure respectively. The average survival of the APP TAH calves has been 65 days. Hematologic study has revealed basically normal results with minimal elevation of serum hemoglobin and lactic acid dehydrogenase (LDH), indicative of a low level of hemolysis. Elelvation of central venous pressure (CVP) and total blood volume continue to be a problem with some TAH calves but not all. The APP has led to a dramatic increase in duration of survival and decrease in thromboembolism.

Animals

A two and one half year clinical experience with a mechanical left ventricular assist pump in the treatment of profound postoperative heart failure.

A sac-type paracorporeal left ventricular assist pump was implanted in 9 patients suffering from profound left ventricular failure following open heart surgery. Two patients had good recovery of left ventricular function and were weaned from assist. One survived 14 months postoperatively. Primary causes of death among the remaining patients were (1) primary right ventricular failure, (2) assist pump inlet cannula obstruction and (3) excessive bleeding. The strategies developed or proposed to deal with these problems include, respectively: (1) biventricular assist for patients with concomitant right ventricular failure; (2) cannulation of the left atrium to avoid inlet cannula obstruction by the left ventricular wall and intraventricular septum; (3) more rapid selection of left assist candidates and more rapid implantation techniques to reduce the coagulopathy associated with prolonged cardiopulmonary bypass, and an effective autotransfusion system to augment blood replacement.

Adult

The artificial heart. Progress and promise.

A multidisciplinary group has designed, fabricated, and evaluated an artificial heart. The heart consists of two smooth-surfaced sac-type pumps, two pneumatic power units, and an electronic control system. The artificial heart has been employed in 22 calves. A variety of problems have been encountered and overcome and a significant improvement in pump design has been made. As a result, a gradual increase in survival times has occurred. The last two calves in which the heart was tested lived for 60 and 42 days respectively. These animals ate well and gained weight. The ability of the control system to balance the output of the two pumps over long periods of time and to automatically increase cardiac output with treadmill exercise has been confirmed. No insurmountable problems in the development of the artificial heart have been identified. The date that an artificial heart will be available for clinical use depends on the availability of funds and on the tenacity of the investigators.

Animals

Design and evaluation of a percutaneous transthoracic cannula.

This investigation was designed to develop a satisfactory PTC for conveying large bore cannulae as required for current use with the artificial heart and left heart assist device. A total of 50 PTCs of varying designs and 6 controls were implanted in the dorsum of canines and goats. Observations with 6 initial designs indicated that necessary requirements in the design of a PTC, include adequate fixation and the use of dacron or nylon velour as the skin interfacing material. Best results were obtained utilizing a PTC having a polycarbonate extra-cutaneous flange, a nylon velour covered polycarbonate subcutaneous skirt, and an extended threaded central conduit to also allow fixation intrathoracicly behind the 2 ribs traversed by the device. Eight such PTCs have been implanted and without complications, have exhibited good tissue ingrowth and have had negative bacterial cultures for periods averaging 6 mos. The use of a PTC of this design should be considered in conjunction with mechanical hearts or left heart assist devices where large bore conduits must cross the chest wall and function on a chronic basis without allowing the ingress of virulent organisms.

Animals

A comparison of three ventricles used for left ventricular bypass in the calf.

Long-term synchronized left ventricular bypass has been performed in calves using pneumatically powered pumps having a smooth lining fabricated of segmented polyurethane. Three different pump designs have been employed: a) sac pump, b) longitudinal tethered sac pump, and c) transverse tethered sac pump. Sizeable thrombi occurred in the apex of the sac and longitudinal tethered sac pumps. In the transverse tethered sac pumps, a considerably smaller thrombus was seen only at the flexion point on the inlet side of the pump. Thrombi occurred in areas of low flow velocity and were not prevented by anticoagulation or surface coating techniques. This study indicates the importance of ventricle design in the development of thrombus free pumps and suggests modifications to the present pumps to reduce or eliminate thrombus formation.

Animals