PubMed HealthSearch

Biomedical subjects

G A Wright

Publications and source records attributed to G A Wright.

10 recordsLinked to original sources

Pulsed saturation transfer contrast.

In vivo 1H conventional NMR image contrast generation usually relies on the macroscopic T1 and T2 relaxation parameters of the tissues of interest. Recently cross-relaxation related image contrast has been reported by Wolff and Balaban in animal models. Due primarily to the broad lineshape of the intended saturation spin pool and the use of off-resonance irradiation, high specific absorption rate and an auxiliary RF amplifier have been necessary to produce these images. The relatively long spin-lattice relaxation property of this spin pool, however, suggests the use of pulse methods to achieve saturation. In this paper, we show that short-T2 spin pools can be selectively saturated with short intense RF pulses. Cross-relaxation time constants can be measured using the technique of saturation recovery. In vivo magnetization-transfer-weighted images can be produced using pulses on commercial whole-body imagers without additional hardware.

Adipose Tissue

Flow-independent magnetic resonance projection angiography.

The performance of current, flow-based sequences for imaging vasculature using MR is severely restricted in regions with inherently slow flow. We address this problem with a flow-independent imaging method. Specifically, we generate projection images of blood in the limbs while suppressing signal from all other tissues (primarily skeletal muscle, bone marrow, and subcutaneous fat) using a flow-compensated, water-selective, short TI inversion recovery sequence with a long echo time. We experimentally evaluate the effectiveness of this sequence and present in vivo results clearly demonstrating the method's potential.

Adipose Tissue

Computing material-selective projection images in MR.

We detail a robust, general method for computing projection images of individual materials in a volume as linear combinations of MR projection images with different material-dependent weightings. Signal per unit volume for each material in each raw image is acquired directly for accurate cancellation of undesired, overlapping materials. The weighted sum of the input images is determined to maximize the signal-to-noise ratio (SNR) and minimize inhomogeneity effects in the material-selective images. We tested the implementation experimentally in both phantom and human studies, producing selective images with reasonable SNRs and material isolation. With further development of sequences to rapidly acquire input images having greater material differentiability, we envision the application of the selective projection imaging format to screening studies searching over large volumes for diseased tissues.

Humans

Tetany and myocardial arrhythmia due to hypomagnesaemia. A case report.

An 11-year-old boy with acute intestinal obstruction presented with tetany, and developed myocardial arrhythmia during anaesthesia. The procedure was abandoned and the patient further investigated. He was found to have hypomagnesaemia and normocalcaemia. Intravenous magnesium sulphate corrected the tetany, and no further arrhythmia occurred during subsequent surgery.

Arrhythmias, Cardiac

1991 I.I. Rabi Award. Estimating oxygen saturation of blood in vivo with MR imaging at 1.5 T.

The use of magnetic resonance (MR) imaging is investigated for noninvasively estimating the oxygen saturation of human blood (%HbO2) in vivo by means of relaxation characteristics identified in earlier MR spectrometry studies. To this end, a sequence is presented for determining the T2 of vascular blood in regions in which motions of the body and of the blood itself present a major challenge. With use of this sequence on a commercial 1.5-T whole-body imager, the relationship between the T2 and %HbO2 of blood is calibrated in vitro for the conditions expected in vivo. T2 varies predictably from about 30 to 250 msec as %HbO2 varies from 30% to 96%. T2 values measured in situ for vascular blood in the mediastinum of several healthy subjects qualitatively reflected the behavior observed in vitro. Estimates of %HbO2 for these vessels obtained with the in vitro calibration appear reasonable, particularly for venous blood, although difficulties arise in selecting the appropriate calibration factors. These encouraging initial results support a more systematic study of potential sources of error and an examination of the accuracy of in vivo measurements by comparison with direct measurements of %HbO2 in vessels.

Awards and Prizes

Noise in stenosis measurement using digital subtraction angiography.

This paper examines statistical errors in the measurement of arterial stenoses by digital videodensitometry. Images of vessel phantoms were acquired using digital subtraction angiographic techniques with low concentrations of an iodine contrast medium and low levels of x-ray exposure. Effects of the spatial and temporal averaging of image information on signal-to-noise ratios in the stenosis measurement were of primary interest. The influences of iodine concentration, x-ray scatter, veiling glare, x-ray energy spectrum, x-ray exposure, and detective quantum efficiency of the system were also included in the theoretical analysis. The agreement between theoretical calculation and experimental measurement of a simulated vessel was verified using measured values of the imaging system parameters. With a 14.2 mg/ml iodine concentration, using 20 mR per image at the entrance to a 13-cm water phantom, and averaging over a 6-mm length of a vessel 6.2 mm in diameter, the standard deviation in a measurement of a vessel's relative cross-sectional area was about 0.05. The extension of these results to practical applications in vivo is discussed.

Angiography