PubMed Health⌕ Search

Biomedical subjects

G Altamura

Publications and source records attributed to G Altamura.

At least 19 recordsLinked to original sources

[Translaryngeal tracheostomy using the Fantoni technique: report of 104 cases].

OBJECTIVE: Surgical tracheostomy morbidity led the authors to investigate new election techniques. The aim of this retrospective study was to assess the translaryngeal tracheostomy (TLT), complications and cost. METHODS: From January 1998 to January 2001, 104 patients were treated with TLT modified: 69 males (66.3%) and 35 females (33.7%), average age 52.6 +/- 9.5 years. The original pathologies were: traumatical (36), neurological (37), surgical (9), heart (4), respiratory (18). The average time between intubation and execution of TLT was 4.2 +/- 1.3 days. RESULTS: Fifty four patients died (52%) and 50 patients lived (48%). Two complications (1.9%) occurred in those who survived: a breaking of the guidewire in traction. Extraction of the tracheostomy tube by clamp, a haemorrhage in 2nd post-operative day due to a thyroid vessel lesion. The haemostasis was performed by classical tracheostomy. The average number of days to decannulation was 25 +/- 1 days. CONCLUSIONS: TLT reduces trauma or trachea and neighbouring structures. This technique is safe and easy. TLT is an effective method, in non-urgent situations, in children and adults, as well as in brachytypes and the obese.

Adolescent↗

Single shock endocavitary low energy intracardiac cardioversion of chronic atrial fibrillation.

BACKGROUND: Discomfort related to low-energy internal cardioversion (LEIC) represents a real problem in patients (pts) with atrial fibrillation (AF). The aim of our study was to verify if a single shock could restore sinus rhythm (SR) with a lower discomfort for the pt. METHODS: Thirty pts with chronic AF were randomized to receive a single 350 V shock (15 pts) or multiple shocks of increasing energy (15 pts). Three leads were positioned, respectively, in the coronary sinus and in the lateral right wall for shock delivery, and in the right ventricular apex for R wave synchronization. Truncated, biphasic shocks were used. In the first group a single 350 V shock was directly delivered and a second 400 V shock was given only if SR has not been restored. In the second group, beginning at 50 volts the voltage was increased in steps of 50 volts until SR restoration. No patient was sedated. After each shock the pts were asked to rate their discomfort on a scale of 1 to 5 (1 = not perceived, 5 = severe discomfort). RESULTS: SR was restored in all the subjects. In group 1 SR was obtained in 12/15 (80%) pts with the first 350 V (8.1 +/- 0.8 joules) shock, while the remaining 3 patients required the second 400 V (10.2 +/- 0.3 joules) shock. In group 2 the mean atrial defibrillation threshold was 346.7 +/- 1029.7 volts (8.0 +/- 101.5 joules). Then discomfort score was 2.5 +/- 0.6 in group 1 and 3.3 +/- 10.6 in group 2 (p < 0.01). CONCLUSIONS: A single shock of 350 V restores SR in the majority of pts with chronic AF; by use this new approach, LEIC is tolerated better than the multiple shocks step-up protocol.

Aged↗

Spatial extension of local pacing capture in the lateral free wall of the right atrium during clinical chronic atrial fibrillation.

OBJECTIVES: The aims of our study were to define the spatial extension of local atrial pacing capture (LAPC) in the right lateral atrial wall and to verify the effects of antiarrhythmic drugs on capture extension. BACKGROUND: Recently, LAPC during spontaneous chronic atrial fibrillation (AF) has been demonstrated directly in humans, but no systematic attempt has been made to evaluate its spatial extension. METHODS: The study was conducted in 14 consecutive patients with chronic AF, nine of whom were taking antiarrhythmic drugs. A Franz catheter for pacing and monophasic action potential recording was positioned in the lateral right atrial wall. An octopolar recording lead was positioned about 10 mm apart. The presence of atrial capture and its extension (number of captured bipolar pairs) were evaluated during decremental pacing. RESULTS: Forty-eight atrial capture attempts were made. LAPC was achieved in all the performed attempts. The AF types immediately before capture were type 1 in 35 (73%) and type 2 in 13 (27%) episodes. In 32 episodes, the capture was lost within 15 seconds and in the remaining 16 pacing was stopped after 15 seconds of stable capture. In 26 episodes, capture extended radially up to 4 cm from the pacing site, in 18 up to 3 cm, in 3 up 1 cm and in 1 up 1 cm. The mean extension in patients being treated with antiarrhythmic drugs was significantly greater than what was seen in untreated patients (3.8 +/- 0.4 vs 2.9 +/- 0.7 cm, p < 0.00001). Capture loss was less frequently observed when all four of the bipolar recording sites had been captured (13/25, 52% vs 19/23, 82%, respectively, p = 0.05). CONCLUSIONS: LAPC in the lateral right atrial wall extends over a radius of 30-40 mm in the majority of capture episodes and is greater in patients treated with antiarrhythmic drugs. Our results suggest that, at least theoretically, simultaneous multisite pacing could be used to terminate AF. Moreover, a reduction in the atrial defibrillation threshold could be expected performing low-energy internal cardioversion during LPC.

Aged↗

Low energy intracardiac cardioversion of persistent atrial fibrillation.

The aims of the study were to verify the efficacy and safety of low energy internal cardioversion (LEIC) in patients with persistent atrial fibrillation (AF) and to identify the factors affecting the atrial defibrillation threshold (ADT). Forty-nine patients with persistent (lasting > or = 10 days) AF underwent LEIC. In each patient, two 6 Fr custom-made catheters with large active surface areas were positioned in the coronary sinus (cathode) and the lateral right wall (anode), respectively, for shock delivery, and a tetrapolar lead was placed in the right ventricular apex for R wave synchronization. Truncated, biphasic (3 ms + 3 ms), exponential shocks were used, beginning at 50 V and increasing in steps of 50 V until sinus rhythm had been restored. Mild sedation (diazepam 5 mg i.v.) was administered to 12 patients. Sinus rhythm was restored in all the subjects with mean voltage and energy levels of 352.0 +/- 80.3 V and 8.2 +/- 3.4 J, respectively. The ADT in patients pretreated with amiodarone (6.4 +/- 1.8 J) was lower than that of patients who had not received any antiarrhythmic drugs (9.2 +/- 3.7) (P = 0.04). No ventricular arrhythmias were induced by any of the atrial shocks, and no other complications were observed. During a mean follow-up of 162.9 +/- 58.7 days, AF recurred in 21 (43%) patients; 71% of these occurred in the first week after cardioversion. LEIC is effective in restoring sinus rhythm in patients with persistent AF. The technique seems to be safe and does not require general anesthesia or, in most cases, sedation. Patients pretreated with amiodarone have lower ADTs.

Adult↗

[Echo-guided radiofrequency percutaneous ablation of hepatocellular carcinoma in cirrhosis using a cooled needle].

INTRODUCTION: Radiofrequency hyperthermia using the newly-developed "cooled-tip" needle is one of the latest US-guided percutaneous treatments of hepatocellular carcinoma arising in cirrhosis. The continuous cooling of the needle tip allows tissue heating and necrosis far from the electrode without tissue charring, which was the major drawback of the old monopolar technique. Herein we report our preliminary results on feasibility and effectiveness of the thermoablation of mono- or paucifocal hepatocellular carcinoma with the cooled-tip needle. MATERIAL AND METHODS: November, 1996, to January, 1998, we treated thirteen cirrhotic patients (mean age 69.5 yrs, 10 men, 12 HCV-positive; 11 in Child's Class A and 2 in Class B) with 19 hepatocellular carcinoma nodules (mean diameter: 27 mm; range: 10-41 mm; 6 with diameter > 3 cm). None of the patients had portal thrombosis and/or extrahepatic spread. We used a radiofrequency generator (100 W power) connected to an 18 G perfusion electrode needle with an exposed tip of 2-3 cm. The circuit is closed through a dispersive electrode positioned under the patient's thighs. A peristaltic pump infuses a chilled (2-5 degrees C) saline solution to guarantee the continuous cooling of the needle tip. The needle was placed into target lesions under US guidance. The interventional procedure was carried out under general anesthesia using Propofol without intubation. Dynamic CT (more recently with the helical technique) was carried out 15-20 days after thermoablation to assess treatment efficacy. RESULTS: In all, 31 thermal injuries (at 1000-1200 mA for 10-15 minutes) were caused in 21 sessions in the 19 hepatocellular carcinoma nodules (mean: 1.5 lesions per nodule and 1.6 sessions per patient). Complete necrosis as assessed at dynamic CT (no enhancement during the arteriographic phase) was achieved in 16 of 19 nodules (84%). No side-effects occurred. During the follow-up (median: 11 months) no death occurred and five patients had recurrent hepatocellular carcinoma appearing either as single nodule or as multinodular liver involvement. CONCLUSIONS: In our experience radiofrequency hyperthermia with the cooled-tip needle permits effective and safe percutaneous ablation of HCC in cirrhosis. In addition, treatment time is short and lesions > 3 cm can be treated. Further experience is needed to better define the role of percutaneous thermoablation in the treatment strategy of hepatocellular carcinoma.

Aged↗

[The efficacy of high- and low-energy intracavitary cardioversion in chronic atrial fibrillation refractory to transthoracic cardioversion].

BACKGROUND: The purpose of our study was to evaluate the efficacy and safety of intracavitary cardioversion (IC) with either high (HEIC) or low (LEIC) energy in patients with chronic atrial fibrillation (AF) refractory to external cardioversion. METHODS: Forty patients underwent IC with either high (30 pts) or low energy (10 pts); HEIC was performed by delivering one or more shocks between one electrode of the lead positioned in the right atrium and a back plate. The following energy values were used in sequence: 100, 200, 300 joules. In LEIC shocks were delivered between two custom-made decapolar leads (one in the coronary sinus and another one in the right lateral atrial wall) beginning from 50 Volts and increasing the voltage by steps of 50 Volts. Another catheter in the right ventricular apex was used for ventricular synchronization. RESULTS: Sinus rhythm was restored in 24/30 (80%) patients undergoing HEIC and in 10/10 (100%) patients undergoing LEIC. No serious or permanent complications occurred. CONCLUSIONS: HEIC and LEIC are effective in patients with AF refractory to external cardioversion. Both the procedures seem to be safe.

Adult↗

Relapsing neoplastic seeding after percutaneous ethanol injection for hepatocellular carcinoma. Clinical and ultrasonographic findings in a cirrhotic patient.

A case of neoplastic implant after percutaneous ethanol injection (PEI) therapy for hepatocellular carcinoma (HCC) occurring in two steps is described. A 74-year-old male cirrhotic patient underwent PEI for a 5-cm HCC nodule. To obtain complete tumoral necrosis, 80 ml were injected under sonographic guidance in four sessions. Ten months after the completion of PEI a subcutaneous nodule was palpated in the abdominal wall within the area of needle punctures. Histologic examination of the excised nodule confirmed the sonographic and Power Doppler diagnosis of metastatic HCC. At the US exam scheduled three months later a non-palpable subcutaneous nodule of 16 mm was appreciated near the surgical wound. Once again metastatic HCC was demonstrated at pathological examination. Copyright 1997 Elsevier Science Ireland Ltd.

Journal Article↗

Local capture by atrial pacing in spontaneous chronic atrial fibrillation.

BACKGROUND: Atrial fibrillation (AF) is considered to be maintained by multiple reentrant circuits without or with a very short excitable gap. However, the possibility of local atrial capture has been shown recently in experimental AF or induced AF in humans. METHODS AND RESULTS: This study was undertaken to evaluate the feasibility of atrial capture-suggestive of an excitable gap-in spontaneous chronic AF. Decremental pacing was performed in 47 right atrial sites in 14 patients with chronic AF, not taking antiarrhythmic drugs. A Franz catheter (for pacing and monophasic action potential recording) and a recording quadripolar catheter positioned about 10 mm apart were used. Local capture was achieved in 41 (87.2%) sites for a total of 100 captures. In 71 episodes the capture was lost within 15 seconds, while in the remaining 29, pacing was stopped after 15 seconds of stable capture. AF types immediately before capture were type 1 in 83 and type 2 in 17 episodes. Type 3 AF was never captured. Pacing cycle at capture was 175.7 +/- 20.9 ms. The baseline atrial interval (FF) was 185.4 +/- 24.5, significantly longer than the FF recorded during pacing immediately before capture (176.0 +/- 19.8 ms) (P < .02). CONCLUSIONS: During spontaneous chronic AF in humans, (1) local capture by atrial pacing is possible up to at least 15 mm from the pacing site, (2) regional entrainment is possible during type 1 and type 2 AF but not type 3 AF, and (3) pacing before capture accelerates AF, probably by transient or local capture. These findings suggest that an excitable gap is present in chronic AF, therefore supporting the hypothesis that leading circle reentry is not the unique electrophysiological mechanism maintaining the arrhythmia.

Aged↗

Changes in intracardiac atrial cardioversion threshold at rest and during exercise.

OBJECTIVES: We sought to analyze in patients with chronic atrial fibrillation (AF) the change in the intracardiac atrial defibrillation threshold (ADT) at rest and during exercise, to quantify the effective risk of low energy endocavitary cardioversion during the effort and to compare the ADT of chronic and reinduced AF. BACKGROUND: Low energy endocavitary cardioversion is a new alternative to transthoracic shock in patients with chronic AF. Nevertheless, patient discomfort and possible induction of ventricular arrhythmias should be further evaluated. METHODS: Sixteen patients with chronic AF were included in the study. Two 6F custom-made catheters (Electro-Catheter, Inc.) were used for shock delivery and one tetrapolar lead for ventricular synchronization. Without sedation and in a random order, patients underwent two sequences of shocks to determine the ADT at rest and during exercise. Exercise was performed isometrically by the superior limbs. Atrial fibrillation was reinduced by atrial pacing. After each shock, the patients were requested to grade their discomfort with a score from 1 to 5. The power of the study was > 90% in detecting a 25% difference in the ADT between groups. RESULTS: Patients were classified into two groups: Nine patients (group A) underwent the first cardioversion during exercise; seven patients (group B) underwent the first cardioversion at rest. In total, the mean (+/-SD) ADT was 6.70 +/- 1.54 J during exercise and 7.02 +/- 1.82 J at rest (p = 0.59). A significantly lower ADT was observed in the second shock sequence than the first one (6.32 +/- 2.09 J vs. 7.40 +/- 0.87 J, p < 0.05). The discomfort score was 3.25 +/- 0.86 at rest and 2.94 +/- 0.77 during exercise (p = 0.09). No complications occurred. CONCLUSIONS: Low energy endocavitary cardioversion is a safe and effective procedure in patients with chronic AF. Discomfort is not generally severe enough to result in procedure termination. The ADT is not influenced by exercise and is higher in chronic than in reinduced AF.

Adult↗

Influence of digital and analogue cellular telephones on implanted pacemakers.

UNLABELLED: The aim of this study was to find out whether digital and analogue cellular 'phones affect patients with pacemakers. The study comprised continuous ECG monitoring of 200 pacemaker patients. During the monitoring certain conditions caused by interference created by the telephone were looked for: temporary or prolonged pacemaker inhibition; a shift to asynchronous mode caused by electromagnetic interference; an increase in ventricular pacing in dual chamber pacemakers, up to the programmed upper rate. The Global System for Mobile Communications system interfered with pacing 97 times in 43 patients (21.5%). During tests on Total Access of Communication System telephones, there were 60 cases of pacing interference in 35 patients (17.5%). There were 131 interference episodes during ringing vs 26 during the on/off phase; (P < 0.0001); 106 at maximum sensitivity level vs 51 at the 'base' value; P < 0.0001). Prolonged pacing inhibition (> 4 s) was seen at the pacemaker 'base' sensing value in six patients using the Global system but in only one patient using Total Access. CONCLUSION: Cellular 'phones may be dangerous for pacemaker patients. However, they can be used safely if patients do not carry the 'phone close to the pacemaker, which is the only place where high risk interference has been observed.

Adult↗

[Electrophysiologic characteristics of the atrium during chronic atrial fibrillation in man].

AIM OF THE STUDY: To evaluate the electrophysiologic characteristics of human atria during chronic atrial fibrillation. METHODS: The study was performed in 24 patients who underwent low energy intracardiac atrial cardioversion for chronic atrial fibrillation before the procedure itself. No patients have been assuming antiarrhythmic drugs for a period of at least 5 half-lives of the drug. In 10 patients the possibility of local capture in several atrial sites (7 tested) by means of high-rate atrial pacing was evaluated. A Franz catheter for recording of monophasic action potential (MAP) and for atrial stimulation was positioned in the right atrium at a distance of 1 cm from a quadripolar catheter which was also positioned for the recording of the bipolar electrogram by the distal and proximal pairs and of the unipolar electrogram by the distal electrode. A decapolar catheter for shock delivery was positioned in the coronary sinus as well. In the remaining 14 patients an additional quadripolar catheter for His recording was positioned but atrial stimulation was not performed. Furthermore, recordings of the bipolar and unipolar electrograms were obtained in several sites and the correlation between MAP and bipolar electrogram morphology was evaluated. The existence of a difference in fibrillation cycle-length in different sites suggestive of a dispersion of refractory periods was also screened. Wells' and Waldo's classification was used for bipolar electrograms whereas MAP was classified into type 1 (regular), type 2 (partially irregular), and type 3 (totally irregular). RESULTS: In 10 patients submitted to atrial stimulation, local capture was obtained in 37 out of 43 stimulation sites (86%). Local capture was more frequently obtained in the lateral wall than in other sites (p < 0.05). The capture was obtained only in type 1 and type 2 atrial fibrillation. In the remaining 14 patients a perfect correlation (100%) between type 1 and 3 atrial fibrillation and type 1 and 3 MAP respectively was observed. In type 2 atrial fibrillation the correspondence was lower (67%). Fibrillation cycle-length contemporary recorded in the 6 different atrial sites were significantly different in 8 patients out of 12 (67%) in whom a stable recording could be obtained in basal conditions. CONCLUSIONS: 1) In chronic atrial fibrillation an excitable gap allowing local capture is present in the majority of patients and in most atrial sites, at least in the right atrium. 2) The morphology of bipolar and MAP recordings are fairly correlated and they reflect the complexity and the degree of synchronization of the arrhythmia. 3) A dispersion of refractoriness seems to contribute to the maintainance of the arrhythmia.

Action Potentials↗

[Acute effects of ventricular and bicameral stimulation on plasma levels of natriuretic hormone].

Atrial natriuretic factor (ANF) is a peptide produced by the atrium in response to increases in atrial pressure. It is a potent vasodilator and recent studies suggest that ANF may modulate vasomotor changes in patients (pts) with pacemaker (PM) syndrome. To evaluate the incidence of pacing mode on peptide secretion, plasma concentrations of ANF were determined in 32 pts (18 men and 14 women, mean age 71 +/- 4 years) with a DDD PM implant. Blood samples were collected one hour after a randomly assigned PM programming either in VVI or DDD mode at 70 ppm. Mean plasma ANF levels were 84.12 +/- 51 pg/ml in DDD mode and 156.0 +/- 15 pg/ml in VVI mode (p < 0.05). In 12 pts presenting ventriculoatrial retroconduction, the ANF levels were 77.16 +/- 50 pg/ml during DDD stimulation and 219.0 +/- 16 pg/ml during VVI stimulation (p < 0.05). ANF level was 88.50 +/- 46 pg/ml in DDD mode and 114.25 +/- 65 pg/ml in VVI mode in the 20 pts without AV retroconduction (p < 0.05). During DDD mode, 18 patients showed a DVI stimulation whereas 14 showed a VDD stimulation: the mean ANF level was 67.40 +/- 15 pg/ml during DVI and 100.40 +/- 28 pg/ml during VDD stimulation; the difference between these data was not significant. The increase in ANF levels during VVI pacing confirms the lower haemodynamic performance of this stimulation mode. The increase of ANF levels during VVI stimulation, which was in the subgroup without AV retroconduction, confirms the benefits of DDD stimulation also in this group of patients as well. Atrial pacing at physiological rates does not trigger the release of ANF.

Aged↗

Indications for dual-chamber (DDD) pacing in implantable cardioverter-defibrillator patients.

New technologic development of implantable cardioverter-defibrillators (ICDs) keeps up with the exponential increase of their use for primary and secondary prevention of sudden cardiac death. The first-generation ICD with limited shock capability alone could be considered adequate in most cardiac arrest victims, but it was not suitable for sudden death prevention in all high-risk patients with cardiac disease. The second-generation ICD was comprised of hybrid pacemaker-defibrillator systems that provided on-demand ventricular antibradycardia pacing. The third-generation devices include additional functions, such as antitachycardia pacing for ventricular tachycardia (VT) reversion and low-energy ventricular cardioversion, in addition to ventricular defibrillation and single-chamber ventricular demand pacing. In the near future, advanced dual-chamber atrioventricular (AV) pacing and defibrillating systems will also be available. The dual chamber ICD will allow atrial inhibited/dual-chamber (AAI/DDD) rate-responsive pacing, simultaneous atrial and ventricular sensing to optimize the arrhythmia identification, and ICD shock delivery in the proper arrhythmia-related chamber. Clinical benefits of these devices compared with their cost and complexity will require careful evaluation.

Cardiac Pacing, Artificial↗

Transthoracic DC shock may represent a serious hazard in pacemaker dependent patients.

External defibrillation is widely used for the termination of various atrial and ventricular tachyarrhythmias, including pacemaker patients. Our study was intended to evaluate the effects of DC shocks in 36 patients with unipolar pacemakers implanted in the right pectoral region (25 DDD, 10 VVI, 3 AAI). The shocks were delivered with paddles on the anterior surface of the thorax, as far as possible away from the pacemaker. The pacing output was programmed at 0.5 msec and 5 V (25 patients), 4 V (1 patient), and 2.5 V (10 patients). Transient loss of capture occurred in 18 patients (50%). These patients, compared with those without capture failure, received higher peak and cumulative shock energies, respectively, 216 +/- 99 versus 123 +/- 50 joules (P < 0.002) and 352 +/- 62 versus 147 +/- 98 joules (P < 0.004) and had a lower pacemaker pulse amplitude (4.0 +/- 1.2 vs 4.6 +/- 1.0 V, P = 0.11). Failure to capture lasted from 5 seconds to 30 minutes (mean 157 sec). In 15 patients the ventricular stimulation threshold was measured before and serially after cardioversion. A six-fold threshold increase was observed 3 minutes after the shock (P < 0.004) with gradual recovery to nearly baseline values at 24 hours. Transient sensing failure occurred in 7 of the 17 patients in whom it could be evaluated (41%). Furthermore, three cases of shock induced pacemaker malfunctions were observed requiring replacement of the stimulator in two patients. In conclusion, the incidence of loss of capture in pacemaker patients subjected to electrical cardioversion/defibrillation is high.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

Do European GSM mobile cellular phones pose a potential risk to pacemaker patients?

A series of in vivo trials were carried out in order to verify whether the electromagnetic field radiated by GSM (Groupe Systemes Mobiles) mobile cellular phones might affect implanted pacemakers. Two European GSM phones of 2-watt power were tested and trials conducted on 101 pacemaker implanted outpatients attending day hospital for routine check-up, who volunteered for trials. Forty-three pacemaker models from 11 manufacturers were tested in all. When the sensing threshold of the pacemakers was set at a minimum and the antenna of the phone was in direct contact with the patient's chest, interference was detected for 26 implanted pacemakers. Specifically, pulse inhibition in 10 of 101 cases, ventricular triggering in 9 of 46 DDD-VDD pacemakers, and asynchronous pacing in 4 of 52 devices. Pulse inhibition was also observed combined with asynchronous pacing in 1 of 52 cases and with ventricular triggering in 2 of 46 cases. Minimum effect duration was ca. 3 seconds but in 6 cases effects continued as long as the interfering GSM signal was on. No permanent malfunctioning or changes in the programmed parameters were detected. Whenever interference was detected, trials were repeated to determine the maximum sensing threshold at which interference persisted (with the antenna in contact with the skin over the pacemaker). Then maximum distance between antenna and pacemaker at which interference occurred was determined at pacemaker maximum and minimum sensing threshold. Under our experimental conditions electromagnetic interference effects were detected at a maximum distance of 10 cm with the pacemaker programmed at its minimum sensing threshold.(ABSTRACT TRUNCATED AT 250 WORDS)

Electricity↗

Effects of oral propafenone therapy on chronic myocardial pacing threshold.

The effects of oral propafenone therapy on pacing threshold were studied in 36 patients chronically paced for sick sinus syndrome or AV block. The pacemakers, all unipolar models and with noninvasive threshold measurement facilities, were: 9 VVI, 15 AAI, and 12 DDD. Each patient received an initial propafenone dose of 450 mg/day, that in 18 cases was increased to 900 mg/day. Threshold was tested at baseline and at each dosage after 7 days of therapy. With the lower propafenone dosage the threshold, measured at 2.5 V, rose from 0.14 +/- 0.10 to 0.21 +/- 0.16 msec (+55%) in the atrium (P less than 0.0001) and from 0.10 +/- 0.08 to 0.15 +/- 0.09 msec (+63%) in the ventricle (P less than 0.0001). In the 18 patients who received both dosages, the mean atrial and ventricular threshold increased from 0.12 +/- 0.10 to 0.17 +/- 0.14 msec with the lower dose and to 0.27 +/- 0.22 msec (+125%) with the higher dose (P less than 0.0001 for both increments). With the 900 mg/day dose, a threshold increment greater than or equal to 300% was observed in 15% of the stimulated chambers. A good linear correlation (r = 0.76) was found between the ventricular threshold increment and the drug induced QRS widening. In conclusion, treatment with oral propafenone increases atrial and ventricular stimulation threshold in pacemaker patients. Threshold increment is dose dependent and proportional to the drug induced QRS widening. In the majority of the cases the threshold increment is not clinically significant, but caution must be used in prescribing high doses of the drug to patients with high baseline threshold.

Aged↗

Transcutaneous cardiac pacing: evaluation of cardiac activation.

The effects of transcutaneous cardiac pacing (TCP) on cardiac activation were evaluated by endocavitary recording (HRA, RVA) in eight patients, in order to test the possibility to obtain a simultaneous atrial and ventricular stimulation. The transcutaneous pacemaker used was the Pace Aid 52 (pacing rate 50-160 ppm, current output 10-150 mA, pulse width 20 sec). The two skin electrodes (surface area 50 cm2) were placed on the chest in anteroposterior position. Ventricular capture was observed in all patients (threshold = 74 +/- 14 mA), simultaneous atrial capture was obtained in only four cases (threshold = 138 +/- 25 mA). In conclusion, our data show that four-chamber simultaneous stimulation by TCP is possible, but only with pacing energies much higher than those usually required to capture the ventricle. The ability of TCP to simultaneously pace the atria and ventricles, though not relevant in the emergency cardiac stimulation for symptomatic severe bradyarrhythmias, could be useful in the treatment of reentrant supraventricular tachycardias.

Adult↗

Transcutaneous cardiac pacing for termination of tachyarrhythmias.

Transcutaneous cardiac pacing (TCP) was used for interruption of tachyarrhythmias in 31 patients: 20 with ventricular tachycardia (VT); eight with atrioventricular reentrant tachycardia (AVRT) and three had atrioventricular nodal tachycardia (AVNT). The stimulators used (Pace Aid 50/52) allow pacing at programmable rates (50-160 ppm) and output (10-200 mA at 20-msec pulse duration), when possible overdrive pacing was used. Short bursts of stimuli were delivered with increasing current intensity until interruption of the arrhythmia or to the maximum energy tolerated by the patient. VTs were interrupted in eight of the 20 patients: four of the six (67%) treated by overdrive pacing and four of the 14 (29%) were treated by underdrive pacing. Supraventricular tachycardias (SVT) were terminated in eight of the 11 patients: seven out of eight (88%) AVT, and one out of three AVNT (33%). We observed two cases of arrhythmia worsening: a VT acceleration and induction of ventricular fibrillation in a patient with AVNT. TCP was well tolerated by the majority of the patients. We conclude that TCP is an effective method for interruption of ventricular and supraventricular reentrant tachycardias, but the risk of arrhythmia worsening must be considered.

Cardiac Pacing, Artificial↗