PubMed Health⌕ Search

Biomedical subjects

G Anagnostopoulos

Publications and source records attributed to G Anagnostopoulos.

9 recordsLinked to original sources

An analytical dosimetry model as a step towards accounting for inhomogeneities and bounded geometries in 192Ir brachytherapy treatment planning.

A simple analytical dose rate calculation model based on primary and scatter separation that treats 192Ir as a monoenergetic source by use of appropriate attenuation and mass energy absorption coefficients is documented for accurate dosimetry in water. This model is then generalized and tested for use in any homogeneous tissue material of radiobiological interest using scatter to primary ratios calculated in water with a material density scaling to account for the difference in the scattering properties of these materials and water. The potential of the analytical model for predicting the effect of the interference of an inhomogeneity is then evaluated by comparison with corresponding Monte Carlo calculations. It is found that regardless of the inhomogeneity dimensions and position relative to the source, the model is capable of increased accuracy (better than 2%) in calculating the primary dose rate at any point not only for low-Z tissue materials but also for high-Z shielding materials where a severe hardening of the primary photons occurs. Overall, for low-Z tissue inhomogeneities the proposed model succeeds in correcting dosimetry results towards the right direction compared to commercial treatment planning systems that currently ignore the effect of phantom dimensions and inhomogeneity interference. Regarding high-Z shielding materials the proposed model accurately predicts the dose reduction just beyond the inhomogeneity (for example it predicts a dose reduction of 47% just behind a tungsten alloy cylinder of 1 cm diameter and 2 mm thickness placed at 1.4 cm away from an 192Ir source, in agreement with corresponding results in the literature) but does not account for the increasing contribution of the laterally scattered photons with increasing distance from the bounded inhomogeneity.

Algorithms↗

A randomized trial to assess the efficacy of interferon-alpha daily in combination with ribavirin in the treatment of naïve patients with chronic hepatitis C.

A randomized trial was conducted to assess the efficacy of interferon-alpha (IFN) daily in combination with ribavirin in 301 naïve patients with chronic hepatitis C (CHC). Patients were randomized to receive ribavirin 1.2 g daily (QD) for 48 weeks with either IFN 5 MU (thrice weekly) TIW for 8 weeks followed by IFN 3 MU TIW for 40 weeks (IFN TIW, n = 154) or IFN 5 MU QD for 8 weeks followed by IFN 3 MU QD for 16 weeks followed by IFN 3 MU TIW for 24 weeks (IFN QD, n = 147). Treatment discontinuation rates, because of adverse events, were similar in the two arms (14.9% in IFN TIW and 14.3% in IFN QD, P = 0.87). The proportion of patients with sustained virological response (SVR) was 27.9% for patients treated TIW and 38.8% for those treated QD (P = 0.046). According to logistic regression analysis, patients in the IFN QD arm had 1.7 times higher probability of achieving SVR, than those receiving IFN TIW (P = 0.038). Low baseline viral load (P = 0.017) and genotype non-1 (P = 0.036) were associated with higher SVR rates. Combination of IFN/ribavirin for 48 weeks is more effective when IFN is administered daily for the first 24 weeks in naïve patients with CHC.

Adolescent↗

3D dose verification in 192Ir HDR prostate monotherapy using polymer gels and MRI.

VIPAR polymer gels and 3D MRI techniques were evaluated for their ability to provide experimental verification of 3D dose distributions in a simulation of a 192Ir prostate monotherapy clinical application. A real clinical treatment plan was utilized, generated by post-irradiation, CT based calculations derived from Plato BPS and Swift treatment planning systems. The simulated treatment plan involved the use of 10 catheters and 39 source positions within a glass vessel of appropriate dimensions, homogeneously filled with the VIPAR gel. 3D high resolution MR scanning of the gel produced T2 relaxation time maps, from which 3D dose distributions were derived via an appropriate calibration procedure. Results were compared to corresponding dose distributions obtained from the Plato and Swift treatment planning systems. Quantitative comparison, on a point by point basis, was based on user adopted acceptance criteria of 5% dose-difference and 3 mm distance-to-agreement. Significant deviations between experimental and calculated dose distributions were found for doses lower than 50% due to the reduced dose resolution of the method in the low dose, low dose gradient region. Measurement errors were observed at 1.0-1.5 mm around each catheter due to MR imaging susceptibility artifacts. For most remaining points the acceptance criteria were fulfilled. Systematic offsets of the order of 1-2 mm, observed between measured and corresponding calculated isocontours at specific segments, are attributed to the 1 mm uncertainty in catheter reconstruction and 1 mm uncertainty in the alignment of the MR and CT imaging planes.

Algorithms↗

Thermoluminescent dosimetry of the selectseed 125I interstitial brachytherapy seed.

This work presents experimental dosimetry results for the new selectSeed 125I prostate seed design for use with the seedSelectron afterloading device, in accordance with the AAPM advisory that all new low energy interstitial brachytherapy seeds should undergo one Monte Carlo (MC) and at least one experimental dosimetry characterization. TLD dosimetry was performed using 120 cylindrical LiF TLD type-100 rods calibrated using a 6 MV photon beam. They were irradiated in solid water phantoms for the experimental determination of the seed dose rate constant, radial dose functions and anisotropy functions. MC simulations were performed for the determination of the TLDs relative energy response that was found position independent and equal to 1.40+/-0.03, and for the calculation of the ratio of dose in liquid water to dose in solid water that was found to be well described by Dliquidwater/Dsolidwater= 1.013*r+0.030 presenting only a minor dependence on polar angle. The selectSeed dose rate constant in liquid water was found equal to 0.938+/-0.065 cGy h(-1) U(-1), which agrees within experimental uncertainties with corresponding MC results of lambdaselect Seed=0.954+/-0.005 cGy h(-1) U(-1). The experimental radial dose and anisotropy function results were also found in good agreement with corresponding MC calculations.

Anisotropy↗

Cross-validation in fuzzy ARTMAP for large databases.

In this paper we are examining the issue of overtraining in Fuzzy ARTMAP. Over-training in Fuzzy ARTMAP manifests itself in two different ways: (a) it degrades the generalization performance of Fuzzy ARTMAP as training progresses; and (b) it creates unnecessarily large Fuzzy ARTMAP neural network architectures. In this work, we are demonstrating that overtraining happens in Fuzzy ARTMAP and we propose an old remedy for its cure: cross-validation. In our experiments, we compare the performance of Fuzzy ARTMAP that is trained (i) until the completion of training, (ii) for one epoch, and (iii) until its performance on a validation set is maximized. The experiments were performed on artificial and real databases. The conclusion derived from those experiments is that cross-validation is a useful procedure in Fuzzy ARTMAP, because it produces smaller Fuzzy ARTMAP architectures with improved generalization performance. The trade-off is that cross-validation introduces additional computational complexity in the training phase of Fuzzy ARTMAP.

Algorithms↗

Childhood acute rheumatic fever in Greece: experience of the past 18 years.

UNLABELLED: This study reports on the authors' experience with acute rheumatic fever (ARF) during the years 1980-1997. The objectives were to estimate the incidence of the disease an area of Greece to characterize its epidemiology, to determine the frequency of the antecedent symptoms and to describe its clinical presentation. The medical records of 66 confirmed cases admitted to the First Department of Pediatrics, "Aghia Sophia" Children's Hospital, were reviewed. Two outbreaks occurred during this period. In contrast to the 3-4 cases seen every year, 14 cases were diagnosed during the 6 mo period from October 1989 to March 1990. An additional 10 cases were diagnosed in 1993. Most of the children (76%) were between 8 and 14 y old. The children were predominantly from middle-class families with ready access to medical care. Carditis, evident by auscultation, and arthritis were the dominant major manifestations in 70% and 68% of the cases, respectively. Mild carditis was present in 54% of children with valvular disease. CONCLUSION: ARF exists in the paediatric Greek population with exacerbations and remissions, but the cardiac manifestations appear mild or moderate.

Adolescent↗

Monte Carlo dosimetry of the selectSeed 125I interstitial brachytherapy seed.

This work provides full dosimetric data for the new selectSeed 125I prostate seed source to be distributed by Nucletron B.V. The AAPM TG-43 dosimetric formalism and the new 1999 NIST air kerma strength calibration standard have been followed. Air kerma strength, dose rate constant, radial dose functions, anisotropy functions, and anisotropy factors were calculated using Monte Carlo simulation. Corresponding calculations were also performed for the commercially available 6711 seed source, which is of similar design, for reasons of comparison. The calculated dose rate constant of the selectSeed was 0.954+/-0.005 cGy h(-1) U(-1) compared to 0.953+/-0.005 cGy h(-1) U(-1) for the 6711 source design. The latter value for the 6711 source suggests that the correction factor proposed by NIST for conversion of dose rate constants to the new 1999 NIST calibration standard may be overestimated by 2-3%. Radial dose functions of the two sources were found in good agreement for radial distances up to 4 cm, the selectSeed being less penetrating at greater radial distances (approximately 4% at 10 cm). The selectSeed source presents similar anisotropy characteristics with the 6711 source design. For both source designs, a distance and polar angle dependent discontinuity of anisotropy function values was observed owing to the dose contribution of radioactivity distributed on the ends of the cylindrical source cores. Variation of dosimetric parameters with possible variation in radioactive silver halide coating thickness of the silver source core of the new source was also investigated.

Anisotropy↗