PubMed Health⌕ Search

Biomedical subjects

G André Ng

Publications and source records attributed to G André Ng.

9 recordsLinked to original sources

Sarcoidosis presenting with tachy- and brady-arrhythmias.

We describe a case report of a 49-year-old man admitted to a cardiology unit with a series of arrhythmias with no initially obvious aetiology. Further assessment and the use of cardiac magnetic resonance imaging and histology allowed a diagnosis of cardiac sarcoidosis to be made. Cardiac sarcoidosis is a major cause of death in patients with systemic sarcoidosis. Cardiac magnetic resonance imaging is an additional diagnostic tool for this condition without ionizing radiation exposure.

Bradycardia↗

Autonomic modulation of electrical restitution, alternans and ventricular fibrillation initiation in the isolated heart.

OBJECTIVE: Abnormal autonomic nerve activity is a strong prognostic marker for ventricular arrhythmias but the mechanisms underlying the autonomic modulation of ventricular fibrillation (VF) initiation are poorly understood. We examined the effects of direct sympathetic (SS) and vagus (VS) nerve stimulation on electrical restitution, alternans and VF threshold (VFT) in a novel isolated rabbit heart preparation with intact dual autonomic innervation. METHODS: Monophasic Action Potentials (MAPs) were recorded from a left ventricular epicardial site on innervated, isolated rabbit hearts (n=16). Standard restitution, effective refractory period (ERP), electrical alternans and VFT were measured at baseline and during SS and VS separately. RESULTS: The restitution curve was shifted downwards and made steeper with SS whilst VS caused an upward shift and a flattening of the curve. The maximum slope of restitution was increased from 1.30+/-0.10 at baseline to 1.86+/-0.17 (by 45+/-12%, P<0.01) with SS and decreased to 0.69+/-0.10 (by 51+/-6%, P<0.001) with VS. ERP was decreased from 127.3+/-2.5 ms to 111.8+/-1.8 ms with SS (by 12+/-2%, P<0.001) and increased to 144.0+/-2.2 ms with VS (by 13+/-2%, P<0.001). VFT was decreased from 4.7+/-0.6 mA to 1.9+/-0.5 mA with SS (by 64+/-5%, P<0.001) and increased to 8.7+/-1.1 mA with VS (by 89+/-14%, P<0.0005). There was a significant inverse relationship between the maximum slope of restitution and VFT (r=-0.63, P<0.0001). When compared with baseline, SS caused electrical alternans at longer pacing cycle lengths (139.0+/-8.4 vs. 123.0+/-7.8 ms, P<0.01) with greater degree of alternans (32.5+/-9.9 vs. 15.4+/-3.2%, P<0.05). It also caused a wider range of cycle lengths where alternans occurred (53.0+/-6.2 vs. 41.0+/-7.0 ms, P<0.05) whilst vagus nerve stimulation shortened this range (33.0+/-7.3 ms, P<0.001). CONCLUSIONS: Sympathetic stimulation increased maximum slope of restitution and electrical alternans but decreased ERP and VF threshold whilst vagus nerve stimulation had opposite effects. The interaction between action potential duration and beat-to-beat interval may play an important role in the autonomic modulation of VF initiation.

Action Potentials↗

The effect of direct autonomic nerve stimulation on left ventricular force in the isolated innervated Langendorff perfused rabbit heart.

The relative contribution of the chronotropic effects of stimulating sympathetic and vagus nerves on cardiac inotropic changes in the isolated Langendorff perfused rabbit heart with intact dual autonomic nerves was studied. The force-frequency relationship was investigated, in addition to sympathetic nerve stimulation (SS) at 2 Hz (low), 5 Hz (med) and 10 Hz (high), and left and right vagus nerve stimulation (VS) studied at 2 Hz (low), 5 Hz (med) and 7 Hz (high) with and without right ventricular pacing. It was shown that a biphasic force-frequency relationship is present with a positive relationship at low heart rates and a negative force-frequency relationship at higher heart rates. There was a trend for left- and right-VS to decrease left ventricular pressure with a decrease in heart rate, whilst SS had the opposing effects in a frequency-dependent manner. When heart rate was kept constant, there was no effect from left- or right-VS, while SS increased left ventricular pressure in a frequency-dependent manner. Together these results suggest that SS, left- and right-VS alter left ventricular force by two different mechanisms. Left- and right-VS decrease left ventricular pressure predominantly via chronotropic effects whilst SS increases force predominantly by direct changes in contractility.

Animals↗

Arrhythmia detection by patient and auto-activation in implantable loop recorders.

AIMS: The Reveal Plus implantable loop recorder offers additional automatic detection of arrhythmias that may not be symptomatic. We evaluated the clinical utility of this function compared with standard patient activation. METHODS: Over an 18 month period, 50 consecutive patients (age 54 +/- 20 years; 24 male) with unexplained dizziness, palpitations and/or syncope had ILR activations which were downloaded for analysis. Patient and auto-activation were analysed with respect to arrhythmia detection and the impact on management of patients was examined. RESULTS: Patient symptoms were syncope in 72% and non-syncope (dizziness and/or palpitations) in 28%. There were 181 patient activation events with 16% showing symptomatic arrhythmia leading to a positive diagnosis in 8 patients. Of 682 auto-activations, detection was appropriate in 17% and inappropriate in 83% (undersensing in 76% and oversensing in 24%). In 8 patients clinically relevant arrhythmia was detected by patient activation alone. In 4 of these patients, further arrhythmia was detected by auto-activation. No patient had important arrhythmia detected only by auto-activation. CONCLUSION: Automatic detection of asymptomatic arrhythmia did not appear to improve the diagnostic utility of the ILR in our series. The large number of stored inappropriate auto-activation events limits the ability of this function to detect clinically relevant arrhythmia. Symptom-rhythm correlation using the patient activation function remains clinically useful in patients with unexplained syncope or palpitation.

Adult↗

Interaction between direct sympathetic and vagus nerve stimulation on heart rate in the isolated rabbit heart.

The interaction between the effects of vagus nerve stimulation (VS) and sympathetic stimulation (SS) on intrinsic heart rate was studied in the novel innervated isolated rabbit heart preparation. The effects of background VS, at different frequencies--2 Hz (low), 5 Hz (medium), 7 Hz (high)--on the chronotropic effects of different frequencies of SS--2 Hz (low), 5 Hz (medium), 10 Hz (high)--were studied. The experiments were repeated in the reverse direction studying the effects of different levels of background SS on the chronotropic effects of different levels of VS. Background VS reduced the overall positive chronotropic effect of SS at steady state in a frequency dependent manner and the rate of increase in heart rate during low and medium SS (but not high SS) was slowed in the presence of background VS. These results suggest that pre- and postjunctional mechanisms may be involved in the sympatho-vagal interaction on heart rate. On the other hand, the chronotropic effect of VS was enhanced in the presence of background SS. Vagal stimulation appears to play a dominant role over sympathetic stimulation in chronotropic effects on the isolated heart. The innervated isolated heart preparation is a valuable model to study the complex mechanisms underlying the interaction between sympathetic and parasympathetic stimulation on cardiac function.

Animals↗

A streamlined "3-catheter" approach in the electrophysiological study and radiofrequency ablation of narrow complex tachycardia.

BACKGROUND: Electrophysiological study (EPS) followed by radiofrequency (RF) ablation has emerged as the treatment of choice for symptomatic narrow complex tachycardia (NCT), for which purpose, 5 catheters are typically used (4 for the initial EPS and an additional one for the subsequent RF ablation). We describe an alternative, streamlined approach using only 3 catheters [2 standard (diagnostic) and 1 deflectable, thermistor tip (mapping)] as the standard configuration for EPS and RF ablation in patients with NCT but no pre-excitation on ECG. METHODS AND RESULTS: Diagnosis was obtained in all 250 consecutive patients (mean age 45 years, 174 females): atrio-ventricular nodal re-entrant tachycardia (AVNRT) in 188 (75%), concealed accessory pathways (AP's) in 38 patients (15%), ectopic atrial tachycardia in 19 patients (8%), persistent junctional re-entrant tachycardia (PJRT) in 4 patients (2%) and atrial fibrillation in 1 patient. An additional diagnostic catheter was used for optimising atrial pacing in 3 patients and for ventricular pacing in concealed right postero-septal AP's in another 3. An additional mapping catheter was used in 31 patients with concealed left-sided AP's, 2 with multiple AP's and 1 with PJRT. Three patients had complications (1 pulmonary embolism, 1 pericardial effusion and 1 atrio-ventricular node block). Overall, the immediate success rate was 98% (224/229) with a recurrence rate of 4.4% (10/224), and the total success rate (with repeat RF ablation if necessary) was 99.2% (227/229) over a median follow-up period of 31.4 months. The average cost saving was US$474 per procedure. Procedure duration (2.0 +/- 0.1 hours), fluoroscopy time (13 +/- 1 minutes) and the number of radiofrequency applications (5.4 +/- 0.3) also compared favourably with values reported in the literature for RF ablation of AVNRT. CONCLUSION: Compared to the conventional 5-catheter configuration for the combined EPS and RF ablation procedure in treatment of patients with NCT, the described 3-catheter configuration reduces cost, procedure duration and fluoroscopy time without compromising on success rate and safety. On these bases, we advocate its widespread adoption.

Adolescent↗

Comparison of the performance of three diagnostic algorithms for regular broad complex tachycardia in practical application.

The authors previously proposed a Bayesian approach to the electrocardiographic diagnosis of regular broad complex tachycardia (BCT), which can be due to VT or supraventricular tachycardia with aberrant conduction (SVTAC). They also published an account comparing the theoretical merits in the design of two of the most commonly used diagnostic algorithms for the same purpose, those of Brugada et al. and Griffith et al. In this study, a direct head-to-head comparison was performed on the practical performances of the three algorithms in this study. A set of 111 ECGs showing regular BCT (77 VT, 34 SVTAC) whose diagnoses were confirmed by electrophysiological study was shown to five internists in general medicine at a district general hospital. The observers were asked to comment on whether the ECG criteria in the three algorithms tested were fulfilled or not, and a computer program then derived the corresponding diagnoses. The sensitivity and specificity for VT achieved by the Brugada algorithm were 92% and 44%, 92% and 44% by the Griffith algorithm, and 97% and 56% by the Bayesian algorithm. The Bayesian algorithm achieved a higher sensitivity and specificity than the other two algorithms, but the differences are not statistically significant (P = 0.6583 and P = 0.5334, respectively). The Brugada, Griffith, and Bayesian algorithms show comparable performances in terms of overall sensitivity and specificity when tested in practice. Of the three algorithms, the Griffith algorithm excels in simplicity and is the easiest to implement in practice. The Bayesian algorithm achieved slightly higher values for sensitivity and specificity than the Brugada and Griffith algorithms but may be more suitable for automated computer-aided diagnosis of ECG due to its complexity.

Algorithms↗

The reliable electrocardiographic diagnosis of regular broad complex tachycardia: a holy grail that will forever elude the clinician's grasp?

The reliable and accurate diagnosis of regular broad complex tachycardia (BCT) by the ECG is a goal that has eluded clinicians and electrophysiologists alike for years. This article explores the reason for this by first giving an historical account on the development of the subject. Next, the electrophysiological mechanisms of ventricular tachycardia, supraventricular tachycardia with aberrant conduction, and preexcited tachycardia, the three main differential diagnoses for regular BCT, according to the latest knowledge from cellular and clinical electrophysiology study will be reviewed, together with considerations on how such understanding may help account for the manifestations of these tachycardias on the ECG and the difficulty in distinguishing between them. Finally, the use of electrophysiological study as the criterion standard for diagnosing regular BCT, as has been the case in most studies on the subject, will be critiqued in terms of the potential for misdiagnosis by the method and the use of any ECG diagnostic algorithms developed with its aid in the acute medical care setting.

Algorithms↗